Tripp Lite SU3000RTXR3U Handleiding

Tripp Lite UPS SU3000RTXR3U

Bekijk gratis de handleiding van Tripp Lite SU3000RTXR3U (15 pagina’s), behorend tot de categorie UPS. Deze gids werd als nuttig beoordeeld door 44 mensen en kreeg gemiddeld 3.9 sterren uit 22.5 reviews. Heb je een vraag over Tripp Lite SU3000RTXR3U of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/15
Owner’s Manual
1111 W. 35th Street Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • www.tripplite.com
Important Safety Instructions 2
Installation 3
Basic Operation 7
Battery Replacement 13
Storage and Service 14
SmartOnline
Rack/Tower Mount On-Line UPS Systems
Warranty Registration 14
Espol
Français 29
15
Copyright © 2009 Tripp Lite. All rights reserved. SmartOnline
is a trademark of Tripp Lite.
Troubleshooting 11
Warranty Registration:
register online today for a chance to
win a FREE Tripp Lite product—
www.tripplite.com/warranty
Not suitable for mobile applications.
UPS Location Warnings
• InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,
dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand
40ºC).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• Do not mount unit with its front or rear panel facing down (at any angle).
Mounting in this manner will seriously inhibit the unit’s internal cooling, eventually
causing product damage not covered under warranty.
UPS Connection Warnings
• ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.Donotplugthe
UPSintoitself;thiswilldamagetheUPS.
• DonotmodifytheUPS'splug,anddonotuseanadapterthatwouldeliminatetheUPS’s
groundconnection.
• DonotuseextensioncordstoconnecttheUPStoanACoutlet.Yourwarrantywillbe
voidedifanythingotherthanTrippLitesurgesuppressorsareusedtoconnectyourUPS
to an outlet.
• IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormust
provideclean,filtered,computer-gradeoutput.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenornitrous
oxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.This
mightdamagetheUPSandwillvoidthesurgesuppressorandUPSwarranties.
Battery Warnings
Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.
Observeproperprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPS
orbatteries.Donotshortorbridgethebatteryterminalswithanyobject.Unplugandturn
offtheUPSbeforeperformingbatteryreplacement.Usetoolswithinsulatedhandles.
Therearenouser-serviceablepartsinsidetheUPS.Batteryreplacementshouldbe
performedonlybyauthorizedservicepersonnelusingthesamenumberandtypeof
batteries(sealedLead-Acid).Thebatteriesarerecyclable.Refertoyourlocalcodesfor
disposalrequirementsorintheUSAonlycall1-800-SAV-LEADor1-800-8-BATTERY
(1-800-822-8837)orvisitwww.rbrc.comforrecyclinginformation.TrippLiteoffersa
completelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecificreplacement
batteryforyourUPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation,operationandstorageofallTrippLiteUPSSystems.Failuretoheedthese
warningswillvoidyourwarranty.
2
Important Safety Instructions
Mountyourequipmentineithera4-postor2-postrackorrackenclosure(seenextpagefor
2-post mounting). The user must determine the fitness of hardware and procedures before
mounting. If hardware and procedures are not suitable for your application, contact the
manufacturerofyourrackorrackenclosure.Theproceduresdescribedinthismanualarefor
commonrackandrackenclosuretypesandmaynotbeappropriateforallapplications.
4-Post Mounting
AllUPSmodelsincludehardwarerequiredtomountina4-postrack.Selectmodelsincludean
adjustable rackmount shelf kit to provide additional support. If your UPS model does not
include an adjustable rackmount shelf kit, skip steps 1 and 2.
Connect the two segments of each shelf A
usingtheincludedscrewsandnuts B.Leave
the screws slightly loose so that the shelves
canbeadjustedinthenextstep.
Adjusteachshelftofityourrack,thenmount
theminthelowestavailablespaceofyourrack
with the screws, nuts and washers provided
C . Note that the support ledges should face
inward. Tighten the screws that connect the
shelfsegments B.
Attachmountingears Dtothefrontmounting
holesof yourequipment Eusing thescrews
provided F.Theearsshouldfaceforward.
Using an assistant if necessary, lift your
equipment and slide it onto the mounting
shelves.Attachyourequipmenttotherackby
usingtheappropriatehardware Gthroughits
mountingearsandintotherackrails.
Mounting Rack
3
Installation
A
B
C
B
E
DF
G
1
2
3
4
1
2
3
4


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: SU3000RTXR3U
Kleur van het product: Zwart
Gewicht: 50500 g
Breedte: 450.8 mm
Diepte: 660.4 mm
Hoogte: 133.4 mm
Snoerlengte: 3 m
Gewicht verpakking: 68040 g
Breedte verpakking: 584.2 mm
Diepte verpakking: 838.2 mm
Hoogte verpakking: 292.1 mm
LED-indicatoren: Ja
Vormfactor: Rackmontage/toren
Land van herkomst: China
Aantal USB 2.0-poorten: 1
Certificering: UL1778, CSA, NOM, FCC Part 15 Category A, FCC Part 68, ROHS
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 2400 W
Temperatuur bij opslag: -15 - 40 °C
Frequentie: - Hz
Mac-compatibiliteit: Ja
Seriële poort(en): 1
Stekker: NEMA L5-30P
(Buitenste) hoofdverpakking hoogte: 292.1 mm
(Buitenste) hoofdverpakking breedte: 584.2 mm
(Buitenste) hoofdverpakking brutogewicht: 68040 g
(Buitenste) hoofdverpakking lengte: 838.2 mm
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Surge energy rating: 480 J
Aantal AC uitgangen: 9 AC-uitgang(en)
Stopcontacttypes: NEMA 5–15R,NEMA 5–20R,NEMA L5-30R
Input-connectietype: L5-30P
Output power capacity: 3 kVA
Ingang operation voltage (min): 110 V
Ingang operation voltage (max): 120 V
Uitgang operation voltage (min): - V
Uitgang operation voltage (max): - V
UPS-topologie: Dubbele conversie (online)
Typische backup tijd op halve lading: 30 min
Typische backup tijd op volledige lading: 12 min
Hot-swap batterij: Ja
Emergency Power Off (EPO): Ja
Output-aansluitingen: 4 x 5-15R\r\n4 x 5-15/20R\r\n1 x L5-30R