Tripp Lite SRCOOL60KRT Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SRCOOL60KRT (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
SRCOOL60KCW Accessory Reference
For detailed installation and operation of any accessory, refer to the Quick Start Guide, Owner’s
Manual, or Installation & Operation Guide included in the package of the relevant optional accessory.
Leak Detection Kit
Model: SRCOOL60KWDR
When this kit is installed, the cooling unit’s water leakage detector will trigger a system alarm when it comes in
contact with water or other liquid, and sound an alert to take proper measures. The detector must be manually
set on-site for leakage detection and installed at a low level. If the lower piping conguration is used, the leak
detection kit should be placed close to the pipeline below the raised floor.
To install, pass one end of the water leakage detector through the small hole located on the lower part of the
cabinet and connect it to the white connector labeled “LD”. No other configuration is required. The cooling unit will
detect the presence of the leak detector and begin monitoring for leaks. For more information on installation, see
section 4.5 in the SRCOOL60KCW Owner’s Manual.
Remote Temp Sensor / Remote Temp and Humidity Sensor
Models: SRCOOL60KRT / SRCOOL60KRTH
For optimal total area cooling, the SRCOOL60KCW features environmental monitoring capability with compatible
sensors. The sensors should be located in different areas throughout the installation to monitor temperature and/or
humidity. Remote sensors should be placed in or near:
• Hot spots (areas of increased temp within the room)
• Critical servers or other electronic equipment
• High-load servers
• The farthest rack being serviced by the SRCOOL60KCW
To install, connect the SRCOOL60KRT or SRCOOL60KRTH to REMOTE SENSOR ports one (1) through four (4) on
the SRCOOL60KCW. For more information, see in the SRCOOL60KCW Owner’s Manual.section 3.8.3
Caution – Do not install the sensor in a dead air zone. Air movement is required for the proper monitoring
of the temperature or humidity.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright Š 2016 Tripp Lite. All rights reserved.
16-07-005 93-3609_revA


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: SRCOOL60KRT
Kleur van het product: Zwart
Gewicht verpakking: 340 g
Breedte verpakking: 152.4 mm
Diepte verpakking: 154.9 mm
Hoogte verpakking: 43.2 mm
Compatibiliteit: SRCOOL60KCW
(Buitenste) hoofdverpakking hoogte: 188 mm
(Buitenste) hoofdverpakking breedte: 208.3 mm
(Buitenste) hoofdverpakking brutogewicht: 1910 g
(Buitenste) hoofdverpakking lengte: 315 mm
Hoeveelheid per (buitenste) hoofdverpakking: 10 stuk(s)