Theben RAM 751 Handleiding
Theben Thermostaat RAM 751
Bekijk gratis de handleiding van Theben RAM 751 (1 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 33 mensen en kreeg gemiddeld 4.2 sterren uit 7 reviews. Heb je een vraag over Theben RAM 751 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

1. Applications
The electronic floor temperature controller is used for
controlling electric:
• direct floor heating
• floor temperature conditioning systems
Features
• Nighttime set-back, input for external clock
• Indicator lamps for "controller calls for heat" and for
set-back operation
• 2-pole mains switch
• Mounting in 60mm flush-type box
2. Description of functions
2.1 Functions
The floor temperature is set via the dial and is measured
by the remote sensor.
The scale of *…5 corresponds to a temperature of
10…50 °C.
Lamps
Red:Controller calls for heat
Green:Set-back mode is activated
2.2 Functions of the set-back input TA
The TA input is used to set various set-back functions,
refer to table below.
The functions are selected via the mains sine half-waves.
The functions correspond to the "Pilot wire" specificati-
on.
Caution-1!
The device may only be opened and installed ac-
cording to the circuit diagram on the device or these
instructions by a qualified electrician. The existing
safety regulations must be observed.
In order to comply with safety class II, the necessary
installation steps must be taken.
This independently mountable electronic device is de-
signed for controlling the temperature in dry and en-
closed rooms only under normal conditions. The devi-
ce confirms to EN 60730, it works according operating
principle 1C
468 931 003 454
Mounting and
Operating Instructions
Electronic floor temperature controller
with set-back input
RAM 751
Half-wave Function
noneno set-back
bothset-back acc. to J2
positivecontrol off
negativeanti-freeze = 10°C
both pulsed shortset-back by 1°C
both pulsed longset-back by 2°C
The anti-freeze function regulates to a temperature of
10°C.
This multi-function input makes it possible to activate
controller functions by means of the various half-waves
of the mains AC voltage:
Normal operation: input open– – – –
Temp. set-back: both half-wavesÄ
Anti-freeze: negative half-waveÅ
Heating off:positive half-wave Ç
2.3 Selecting the set-back temperature
By means of the J2 jumper it is possible to select 3°
or 5°.
J2 closedset-back by 5°C (factory pre-set)
J2 openset-back by 3°C
The temperature set externally via the dial is reduced by
this value.
2.4 Fault of the floor sensor
If a sensor fault (short-circuit or break) occurs, the con-
troller will switch to fault mode. The heating will func-
tion with max. 30% of the energy (operation for 30% of
the time). This provides frost- and overheat protection.
In the event of a sensor fault, both lamps will flash.
2.5 Function of the lamps
FunctionLamp greenLamp red
Heating is onon
Set-back modeon
Floor sensor faultflashesflashes
3. Electrical connection
Perform the steps described below:
• Pull off the temperature dial
• Release the fixing screw
• Remove the upper part of the casing
• Connect acc. to circuit diagram (see bottom of casing)
Floor sensor F 193720
The remote sensor must be mounted in such a way that
the temperature to be limited can be correctly re-
corded.
The remote sensor should be installed in a protective
tube. This will facilitate future replacement.
Do not install the sensor close to power lines. In other
cases a shilded cable has to be used.
The sensor can be extended to max. 50 m by means of
a cable suitable for mains voltage.
Caution!
The sensor lines are on mains voltage (230V).
Caution! De-energize the electric circuit first
4. Technical data
Order designationRAM 751
EDP No.:751 0 131
Temperature setting range:
Floor temperature*…5 (= 10…50ºC)
Indicator lamp redController calls for heat
greenSet-back temperature
Power switch2-pole
Supply voltage230V AC (195…253V) 50Hz
OutputRelay make contact
Switching current100mA…16A cos= 1;ϕ
100mA…4A cosϕ= 0.6
Control algorithmProportional controller
(similar to continuous
through PWM)
Switching temperature
differential ~1°C
Temperature sensorType F 193720 (length 4 m,
can be extended to max.50 m)
Temperature set-back3K or 5K selectable s. 2.3
vie external timer
Range limitationin the dial
Degree of protection
of casing IP 30
Safety classII (see Caution-1)
Degree of pollution2
Software classA
Calculation impulse voltage2,5 kV
Temperature for the
Ball compression test75°C
Voltage and Current for
the for purposes of inter-
fernce measurements230V, 0.1A
Ambient temperature0…40ºC
Storage temperature–25…70ºC
Weight90 g
Characteristics for remote sensor
10°C66.8 k30°C26.3 kΩ Ω
20°C41.3 k40°C17.0 kΩ Ω
25°C33 k50°C11.3 kΩ Ω
5. Circuit diagram
Position of the jumpers
6. Dimensions
Theben AG · Hohenbergstr. 32
72401 Haigerloch · DEUTSCHLAND
Fon+49 (0)7474/692-0
Fax+49 (0)7474/692-150
Service
Fon+49 (0)7474/692-369
Fax+49 (0)7474/692-207
hotline@theben.de
Adresses, telephone numbers etc.
at www.theben.de
cover 2 parts (50x50)
for conduit boxes
according to DIN 49073
Product specificaties
| Merk: | Theben |
| Categorie: | Thermostaat |
| Model: | RAM 751 |
Heb je hulp nodig?
Als je hulp nodig hebt met Theben RAM 751 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermostaat Theben
15 Februari 2024
29 December 2023
29 December 2023
29 December 2023
29 December 2023
28 November 2022
29 November 2022
28 November 2022
9 Juni 2023
31 Mei 2023
Handleiding Thermostaat
Nieuwste handleidingen voor Thermostaat
16 Januari 2026
23 December 2025
22 December 2025
22 December 2025
22 December 2025
21 December 2025
20 December 2025
20 December 2025
19 December 2025
19 December 2025