Bekijk gratis de handleiding van Techno Line WS 6840 (2 pagina’s), behorend tot de categorie Weerstation. Deze gids werd als nuttig beoordeeld door 42 mensen en kreeg gemiddeld 4.4 sterren uit 21.5 reviews. Heb je een vraag over Techno Line WS 6840 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

LED Radio-Controlled Clock WS 6840
Key Features:
` DCF-77 radio controlled
` 12/24 H display.
` Time zone setting: -12 to +12 Hour.
` Dual Alarm with snooze function
` Indoor Temperature display in °C/°F
` Outdoor Temperature display in °C/°F
Power on or Reset:
` After power on or Reset, all LEDs turn on accordingly, buzzer beeps, unit enter RF Searching mode for Max. 3
minutes, then exit RF Searching mode and enter normal mode.
Clock setting:
` At normal mode, Press and hold the “MODE” key more than 2 seconds, can set 12/24HR Æ Æ Æ Hour Minute
Offset time.
` Corresponding icon flash at 1Hz, and press “UP” or “DOWN” ”key to set the value, and hold “UP” or “DOWN key for
fast increasing or decreasing.
` Press “MODE” key to confirm the setting and come to next setting, unit will return to Normal Mode after finish
setting.
F.Y.I.:
` At any other mode, if without key operation for 15 seconds, the unit will store current setting and return to Normal
Mode automatically.
` How to set Offset Time : Offset time means the time different between local time and Germany time; If local time is
1 hour faster than Germany time, then set the offset time to +1HR; If local time is 1 hour slower than Germany time,
then set the offset time to -1HR; Unit’s clock will automatically set to local time after receiving DCF signal
successfully.
Alarm Setting:
` At normal mode, Press “Mode” key to toggle the display among Clock Æ AL1 time Æ AL2 time, When AL1 or AL2
time be displayed ,press and hold “Mode” key more than 2 seconds to set Hour & Minute, corresponding icon
flash at 1Hz. press “UP” or “DOWN” key to set the value, and hold “UP” or “DOWN”key for fast increasing or
decreasing.
` When AL1 or AL2 icon flash, Press “Down” key to enable(Corresponding Alarm LED turn on) or
disable(Corresponding Alarm LED turn off) alarm. Unit will return to normal mode after finish setting
` Alarm sound crescendo for 2 minutes.
` During alarm, press “SNOOZE” key to stop the alarm and enable snooze function (Corresponding Alarm LED flash
at this status), the unit will alarm 5 minutes later.
` During alarm or Snooze function enable, press any other keys except “SNOOZE” key, will cancel the alarm or
Snooze function.
Indoor Temperature Measurement:
` Indoor Temperature measurement range: -9°C ~ +49°C, “LLL” will displayed if value lower than -9°C, “HHH” will

displayed if value higher than +49°C, resolution is 1°C/℉,accuracy is +/-1.5°C at 0°C ~ +40°C.
` Indoor temperature will be measured interval 30 seconds.
` At normal mode, press “DOWN“ key to select °C or °F.
` At normal mode, press “MEMORY“ key to display Max. or Min. indoor & outdoor temperature, Memory will cleared
if press & hold “MEMORY“ key more than 2 seconds.
RCC Receiving:
` At 1:00 /2:00 / 3:00 am, unit will automatically receive Ra , corresponding LED flash; If dio signal for Max. 7 minutes
receive successfully, Clock will be synchronized and RCC LED be on, otherwise RCC LED be off ;
` Press and hold the “WAVE“ key can enable or disable the RCC receiving manually.
F.Y.I.:
` We recommend a minimum distance of 2.5 meters to all sources of interference, such as televisions or computer
monitors
` Radio receiving is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In such extreme
circumstances, place the unit close to the window.
RF Receiving:
` At RF searching mode, “--.-” icons flash, unit will receive the RF signal from Outdoor Temperature Transmitter,
When outdoor temperature value be displayed ,indicate that the transmitter have been registered, and main unit
will exit RF searching mode immediately.
` Main unit only can register 1pc Transmitter.
` Transmission distance is up to 30m.
` If main unit display “--.-” ( Not flash ), it means that the transmitter have been lost link. Please press and hold
“UP“ key to enter RF searching mode (“--.-” icons flash ) to search the transmitter!
` When Outdoor Temperature Transmitter in Low Battery, “LO” (Indicate Transmitter in Low Battery status) &
“Temperature Value” will be displayed alternatively.
F.Y.I.:
` If Transmitter lost link frequently, please move the Transmitter close to main unit!
Weather Forecast:
` Weather forecast include Sunny / Partly Cloudy / Cloudy / Rainy.
Remarks:
1, To save power, when powered by batteries only, the unit will turn off display. And display turn on for 10
seconds if press any keys except “WAVE“ key.
2, Display will be always on if powered by adapter.
3, During RCC receiving, to lower interference , all LEDs off except RCC LED flash .
Product specificaties
Merk: | Techno Line |
Categorie: | Weerstation |
Model: | WS 6840 |
Heb je hulp nodig?
Als je hulp nodig hebt met Techno Line WS 6840 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Techno Line
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
18 November 2024
Handleiding Weerstation
- Elro
- Medisana
- Davis
- Prologue
- Chauvin Arnoux
- Uzoli
- Buienradar
- Oregon Scientific
- Marathon
- Majestic
- TFA Dostmann
- GlobalTronics
- Tanita
- Konyks
- Ade
Nieuwste handleidingen voor Weerstation
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
10 Juni 2025