Bekijk gratis de handleiding van Taylor 806 (1 pagina’s), behorend tot de categorie Voedsel thermometer. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.2 sterren uit 2 reviews. Heb je een vraag over Taylor 806 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

INSTRUCTION MANUAL
806/806E/806GW
806/806E/806GW 5.25 WC
ONE YEAR LIMITED WARRANTY
Taylor® warrants this product to be free from defects in
material or workmanship (excluding battery) for one (1) year
from the original purchaser from the date of retail purchase. It
does not cover damages to wear resulting from accident,
misuse, abuse, commercial use, or unauthorized adjustment
and/or repair. If help or troubleshooting is required, do not
return to retailer. Should this product require service (or
replacement at our option), while under warranty, contact
Taylor for return authorization and troubleshooting assistance.
Phone: 866-843-3905 (8-5pm MST, M-F)
Email: [email protected]
Web: taylorusa.com
There are no express warranties except as listed above. This
warranty gives you specific legal rights, and you may have
other rights which vary from state to state. For additional
product information, or warranty information outside the USA,
please contact us through www.taylorusa.com.
Made to our exact specifications in China.
©2025 Taylor, a division of Lifetime Brands Inc. All rights
reserved. Oak Brook, IL 60523
GENERAL OPERATION
CLEANMEASURE FEATURE
CALIBRATION
BATTERY REPLACEMENT
The thermometer operates on 1 CR2032 (3V) lithium battery. If
the unit does not turn on for first use, remove and then reinstall
the battery. Change the battery when the display becomes dim.
To replace battery:
1. Using a coin or tool in the slot, press in on the door then turn
it counterclockwise to open.
2. Remove used battery and insert new one, with the "+" sign
facing up.
3. Close the compartment. Make sure the o-ring is seated
around the opening to maintain waterproof feature. Note: If
battery door is not closed properly, water can get into the
battery compartment causing the unit to malfunction.
CleanMeasure™ surface protection inhibits bacterial growth on the
plastic sleeve only to ensure a safer, more hygienic thermometer.
Cleaning still required before and after each use..
Waterproof Digital Thermometer
1. Sterilize the metal probe by inserting it into an appropriate
solution such as boiling water for several minutes.
2.On/OFF Press "" to turn the unit on. Press again for a 5 second
backlight. Press "" to select temperature scale. Note: To ºF/ºC
save battery life, this unit has an AUTO-OFF feature that turns
the instrument off after 5 minutes if no buttons are pressed and
the temperature reading is lower than 122°F (50°C). Press and
hold “ to turn off manually.On/OFF”
3. The sensor is located in the probe tip for a quick response and
accurate reading. When ready to test the temperature, insert
thermometer probe into the center of the product for an
accurate temperature measurement. The LCD will stabilize when
reading is complete (approximately 10 seconds).
4.Hold Hold Feature: Press the "" button and the temperature will
be held (the "HOLD" icon will appear). Press again to release.
5.Max/ Max Feature: Press the "s" button once to read the
maximum temperature that the probe has reached (the word
“Max” will appear). Press the " button again to read the Max/s"
minimum temperature that the probe has reached (the word
“Min” will appear). Press "" a third time to return to the Max/s
current temperature reading. Otherwise the unit will
automatically return to the current temperature reading after 10
seconds.
6. To avoid burns near heat, snap the pocket sleeve onto the
opposite end of the thermometer and use as a handle.
If recalibration is necessary, for best results calibrate within the
temperature range most commonly used. Always utilize a reliable
source as a benchmark when calibrating. If a verified reference
temperature cannot be achieved in the usage range, then calibrate
in an ice bath as described in Step 1.
1. Suspend probe at least 1” into a 'slush' of crushed ice and water
(32°F) for at least 30 seconds. Keep the probe from touching the
container bottom.
2. Press and hold the “SET” button for 5 seconds. The word “SET”
will appear. Then press "Max/s" and "Hold/t" at the same
time to enter Temperature Setting mode. The LCD will turn red.
The current temperature blinks.
3. Press "Max/s" or "Hold/t" to increase/decrease the
temperature by 1°F (0.5°C)
4. To enter the recalibrated temperature, press and hold the “SET”
button for 5 seconds. The LCD will turn green. A “----” pattern
appears, then “OK”.
5. After 2 seconds, the unit will return to normal mode.
6. To restore the default calibration temperature, remove the
battery for 1 minute and then replace it. (Note: If no buttons are
pressed for 30 seconds, the unit will automatically return to normal
mode.)
806_806E_806GW IM Updated again
Origin Date: 3/20/24
Revised Date: 8/26/24
Today’s Date: 5/27/25
Designer: Wendell W. Cisco II
Front
Back
• Remove and immediately recycle or dispose of used
batteries according to local regulations and keep away from
children. Do NOT dispose of batteries in household trash or
incinerate.
• Even used batteries may cause severe injury or death.
• Call a local poison control center for treatment information.
• This product works on 1 x CR2032 (3V) batteries. Always
purchase the correct size and grade of battery most suitable
for the intended use.
• Non-rechargeable batteries are not to be recharged.
• Do not force discharge, recharge, disassemble, heat above
60°C, or incinerate. Doing so may result in injury due to
venting, leakage or explosion resulting in chemical burns.
• Ensure the batteries are installed correctly according to
polarity (+ and -).
• Do not mix old and new batteries, different brands or types of
batteries, such as alkaline, carbon-zinc, or rechargeable
batteries.
• Remove and immediately recycle or dispose of batteries
from equipment not used for an extended period of time
according to local regulations.
• Always completely secure the battery compartment. If
the battery compartment does not close securely, stop
using the product, remove the batteries, and keep them
away from children.
• PRECAUTION: Do not dispose of batteries in fire.
Batteries may explode or leak.
• Clean the battery contacts and also those of the device
prior to battery installation.
• WARNING: Batteries may pose a choking hazard. As with
all small items, do not let children handle batteries. If
swallowed, seek medical attention immediately.
• Tell others about the risk associated with button
batteries and how to keep their children safe.
Product specificaties
| Merk: | Taylor |
| Categorie: | Voedsel thermometer |
| Model: | 806 |
Heb je hulp nodig?
Als je hulp nodig hebt met Taylor 806 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Voedsel thermometer Taylor
4 Mei 2026
11 Augustus 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
11 Juni 2025
7 Februari 2025
9 September 2024
9 September 2024
9 September 2024
Handleiding Voedsel thermometer
Nieuwste handleidingen voor Voedsel thermometer
5 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026
19 Maart 2026
5 Maart 2026
3 December 2025
12 Oktober 2025
3 Oktober 2025
3 Oktober 2025