Supermicro SuperServer 5039MS-H12TRF Handleiding

Supermicro Server SuperServer 5039MS-H12TRF

Lees hieronder de đź“– handleiding in het Nederlandse voor Supermicro SuperServer 5039MS-H12TRF (9 pagina's) in de categorie Server. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/9
Information for Lot 9 of d )ErP (Eco esign
This addendum addresses E European Union (EU) codesign requirements for servers and storage
products addendum product. All and ratings within this data are in reference only Supermicro to the (s) in
the manual. The below information conforms ommission to requirements laid down Cin Annex II of the
R . egulation 2019/424
3(1)(a): e See Section 1.1 of th system manual for the product type.
3(1)(b): See the title page and preface of the system manual for the trademark and
manufacturer’s address.
3(1)(c): (s). See the title page of the system manual for product model number
3(1)(d): . See the serial number on the physical system to determine the year of manufacture
3(1)(e-j): PSU E actor V ) (F fficiency and Power F alue (Table rom 80 Plus report)
PSU Model #: PWS 2K04F 1R- -
Watts:
2000
PSU E fficiency
P Fower actor
% of R Lated oad
% % % %10 20 50 100
50 %
Single -Output (AC DC)
94. %06
95. %75
96.30 %
93. %84
96.30
E P System (EUT) fficiency in I Sdle tate ower (Table)
Representative
Configurations
Measured Idle State
Power (W)
Calculated Idle Power
Allowance (W)
High nd -E Performance
C onfiguration
242.3
431.82
Typical Configuration
N/A
N/A
Low erformance -E Pnd
C onfiguration
232.8
420.98
System E P(EUT) fficiency in A Sctive tate ower (Table)
Representative
Configurations
E Score fficiency
Minimum A Sctive tate
Efficiency for Multi- node
S erver
High nd -E Performance
C onfiguration
16.7
Typical Configuration
N/A 12
Low erformance -E Pnd
C onfiguration
16.4
3(1)( is k): The operating condition class A2.
Dry bulb temp °C
Humidity -range (non condensing)
Operating
condition
class
Allowable
range
Recom
mended
range
Allowable range
Dew Point (DP)
Relative Humidity
(RH)
Recommended
range
Max dew
point (°C)
Maximum
rate of
change
(°C/hr)
A1
15 32-
18 27-
–
12 and°C DP
8 %
RH to
17 °C DP and
80 % RH
–
9 °C DP to
15 °C
DP and
60 % RH
17
5/20
A2
10 35-
18 27-
–
12 DP °C and 8 %
RH to
21 DP °C and
80 % RH
Same as A1
21
5/20
A3
5-40
18 27-
–
12 DP °C and 8 %
RH to
24 DP °C and
85 % RH
Same as A1
24
5/20
A4
5-45
18 27-
–
12 DP °C and 8 %
RH to
24 DP °C and
90 % RH
Same as A1
24
5/20
3(1)(l): The idle state power at the higher boundary temperature of the operating conditions
class is 242.3 W.
3(1)( is 16.7m): The active state efficiency and performance .
3(1)(n): There are two methods by which a user can securely delete data from this system. The
user performing secure data deletion should be an IT professional.
The first is with a Unified Extensible Firmware Interface (UEFI) shell utility. This utility
works on X10/X11/H11/H12/M11 motherboard series with onboard SATA/NVMe devices.
Any user may access and download this utility through following link:
https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Secure
_Data_Deletion_Utility/
Download the shell utility package and extract it to a USB flash drive, then plug the drive
into the server for which secure data deletion is necessary. Then turn the system on.
Navigate to the BIOS setup menu, then place the server system into the UEFI shell
environment. Follow the instructions in the README file to invoke the utility and
complete the deletion.
The second method is through the secure data deletion tool provided by the original
manufacturer of the hard drive. This should be used in a scenario where the shell utility
is not applicable. Each manufacturer should have the tool available on their website. If
needed, please look on the hard drive label for the name of the manufacturer and model
information.
3(1)(o): List of recommended combinations of blade servers with chassis: N/A.
3(1)(p): - - . List of all current SKUs within this product family: SYS 5039MS H12TRF
3(3)(a): There is no use of cobalt in batteries in this product.
The indicative weight range of eodymium in the HDD is if manufactured by Western n 0.0
Digital, and is 25 grams if manufactured by Seagate.between 5-
3(3)(b): Please see the disassembly instructions on the next page.
Illustrated System Disassembly Instructions
Please note:
All the illustrations in the below disassembly instructions are for demonstration only.
Components shown here may not match exactly with the components in your system.
CAUTION: Always power off the system and unplug the power cord(s) first
before disassembling the system!
1. Data Storage Devices
Type and number of fastenings:
. Four (4) Phillips screws per hard drive
Tools required:
Screwdriver with PH2 bit.
Procedure:
Press and hold down the release tab on the front of the node and pull the node from
the system. Remove the screws shown in the pictures below from the bottom of the tray.
OR
One (1) 3.5” and Two (2) 2.5” HDD Two (2) 3.5” and Four (4) 2.5” HDD


Product specificaties

Merk: Supermicro
Categorie: Server
Model: SuperServer 5039MS-H12TRF