Supermicro SuperServer 2029U-MTNRV Handleiding

Supermicro Server SuperServer 2029U-MTNRV

Lees hieronder de 📖 handleiding in het Nederlandse voor Supermicro SuperServer 2029U-MTNRV (1 pagina's) in de categorie Server. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
* SAS3 support requires additional parts in
optional parts list
**NVMe support requires additional parts in
optional parts list
PSU2 PSU1
X11DPU-V
DESIGNED IN USA
BAR CODE BMC CODE
CPU2
CPU1
BIOS
LICENSE
COM1
LAN
CTRL
LED_P1_D2
LED_P1_D1
LED_P1_E2
LED_P1_E1
LED_P1_F2
LED_P1_F1
LED_P1_A2
LED_P1_A1
LED_P1_C2
LED_P1_B1
LED_P1_B2
LED_P1_C1
LED_P2_F2
LED_P2_F1
LED_P2_E2
LED_P2_E1
LED_P2_D2
LED_P2_D1
LED_P2_C2
LED_P2_C1
LED_P2_B2
LED_P2_B1
LED_P2_A2
LED_P2_A1
JRK1
S-UM12
JVGA2
BT1
JBT1
JL1
JUIDB2
JF1
JPG1
JVRM1
JWD1
FAN8
FAN7
FAN6
FAN5
FAN4
FAN3 FAN2 FAN1
JIPMB1
JNVI2C1
JNVI2C2
SP1
JSD1JSD2
T-SGPIO3
LED1
LEDM1
LEDPWR
JVRM2
JTPM1
SXB3B
SXB1B
SXB2
FAIL LEDUID NIC2 1NIC LEDHDD PWRLED X NMIPWRON
JF1
RS T PS
P2_NVMe1
P2_NVMe0
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMME2
SXB1A
CPU2_PO RT3A CPU2_PORT2C CPU2_ PORT2A
SXB1C
P2-DIMMD2
P2-DIMMD1
CPU2_PORT1A PCH_POR T1 CPU2_D MI
USB3/4 (3.0)
S-SATA0~3
S-SATA4
P2-DIMMA2
S-SATA5
P2-DIMMA1
UID
P2-DIMMB2
P2-DIMMB1
P2-DIMMC2
I-SATA0~3
P2-DIMMC1
I-SATA4~7
GPU PWR2
USB2 (3.0)
P1-DIMMF2
SXB3C P1-DIMMF1
CPU1_PORT1A
SXB3A
CPU1_PO RT3A CPU1 _PORT3C CPU1_PORT2 A
CPU1_PORT2 C
P1-DIMMD1
P1-DIMME1
P1-DIMME2
P1-DIMMD2
P1-DIMMA2
P1-DIMMA1
P1-DIMMC1
P1-DIMMC2
P1-DIMMB2
P1-DIMMB1
P1_NVMe0 P1_NVMe1
BP PWR4
VGA
IPMI_LAN
USB0/1
(3.0)
BMC
JSDCARD1
PCH
GPU PWR3 GPU PWR4
GPU PWR1
BP PWR2 BP PWR1
BP PWR3
CPU2_PO RT3C
REV:1.10
JHFI2
JHFI1
http://www.supermicro.com LBL-2050-QRG
Board Layout
SuperServer 2029U-MTNRV Quick Reference Guide
Rev 1.0
Description
SXB1A/1B/1C: Proprietary PCI-e Slot used for
WIO-Left Devices (supported by CPU2)
SXB2: Proprietary PCI-e Slot for WIO-Right Devices
(supported by CPU2)
I-SATA0~3, I-SATA4~7: SATA 3.0 Ports (Intel PCH)
S-SATA 4, 5: SATA 3.0 Ports (Intel SCU)
JBT1: CMOS Clear
SXB3A/3B/3C: Proprietary PCI-e Slot for Ultra Riser
Devices (supported by CPU1)
BMC Password Label
P1-DIMMC1(Blue)/P1-DIMMC2/P1-DIMMB1(Blue) slot
P1-DIMMB2/P1-DIMMA1(Blue)/P1-DIMMA2 slot
CPU1 (Install CPU1 first)
P1-DIMMD2/P1-DIMMD1(Blue)/P1-DIMME2 slot
P1-DIMME1(Blue)/P1-DIMMF2/P1-DIMMF1(Blue) slot
P2-DIMMC1(Blue)/P2-DIMMC2/P2-DIMMB1(Blue) slot
P2-DIMMB2/P2-DIMMA1(Blue)/P2-DIMMA2 slot
CPU2
P2-DIMMD2/P2-DIMMD1(Blue)/P2-DIMME2 slot
P2-DIMME1(Blue)/P2-DIMMF2/P2-DIMMF1(Blue) slot
JSD1/JSD2: SATA DOM (Device_on_Module)
Power Connectors
S-SATA0~3: SATA 3.0 Ports (Intel SCU)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
CPU Installation
BMC Password Label
Control Panel Service/Asset Tag
Storage Drives Fans
DescriptionNo. DescriptionNo.
1 2
3 4
Front view
Control Panel
Beep Codes
Caution
Rear View
19
18
6 71 2 53 4
BMC ass P word Label
BMC: XXXXXXXXXXXX
PWD: XXXXXXXXXX
891113 12141617 15 10
Each system comes with a unique default
password for the ADMIN user.
This can be found on a sticker on the
motherboard and a sticker underneath
the service tag on chassis.
If necessary, the password can be reset
by the Supermicro IPMICFG tool.
For more information, please visit
https://www.supermicro.com/en/solutions/
management-software/bmc-resources
Memory Support
Memory Population Table
When 2 CPUs are used Memory Population Sequence
CPU1: P1-DIMMA1/P1-DIMMD1
CPU2: P2-DIMMA1/P2-DIMMD1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1
CPU1: P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1
CPU2: P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/P1-DIMME2/P1-DIMME1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/P1-DIMME2/P1-DIMME1
CPU2: P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/P2-DIMME2/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/P2-DIMME2/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMC2/P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/
P2-DIMME2/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMC2/P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/
P2-DIMME2/P2-DIMME1/P2-DIMMF2/P2-DIMMF1
CPU1: P1-DIMMA1
CPU2: P2-DIMMA1
2 CPUs & 2 DIMMs
2 CPUs & 4 DIMMs
2 CPUs & 6 DIMMs
2 CPUs & 8 DIMMs
2 CPUs &10 DIMMs
2 CPUs & 12 DIMMs
2 CPUs & 14 DIMMs
2 CPUs & 16 DIMMs
2 CPUs & 18 DIMMs
2 CPUs & 20 DIMMs
2 CPUs & 24 DIMMs
2 CPUs & 22 DIMMs
(Unbalanced: not
recommended)
Chassis Rear Features
Features Description
LAN
Two or four LAN ports, depending
on your Ultra riser card
(see Section 1.1 Overview for
details; also see LAN numbering
description below)
PCI
Item
Features Description
Item
2
USB Two USB 3.0 ports
3
IPMI LAN Dedicated LAN port for IPMI
4
COM Serial port
5
UID UID indicator and button to toggle
the UID indicators
6
8
9 PCI PCI-E 3.0 p1-x8 LP Slot
10 PCI PCI-E 3.0 p1-x8 Internal LP Slot
11 PCI PCI-E 3.0 p1-x8 Slot (FH, 10.5"L)
Or 2x 2.5" Hot-Swap Drive Bay
12 PCI PCI-E 3.0 p1-x8 LP Slot
PCI-E 3.0 p1-x8 Slot (FH, 10.5"L)
Pull-out tag with BMC
unique password
underneath.
PULL
Power Supply
Two redundant power supply
modules, PWS1 on the left,
PWS2 on the right
VGA Video port
1
7
1112 910
1 2 3 4 5 6 7 8
SAFETY INFORMATION
IMPORTANT: See installation
instructions and safety warning
before connecting system to
powersupply.
http://www.supermicro.com/about/
policies/safety
_
information.cfm
!WARNING:
To reduce risk of electric shock/
damage to equipment, disconnect
power from server by disconnecting
all power cords from electrical outlets.
If any CPU socket empty, install
protective plastic CPU cap.
!CAUTION:
!
Always be sure all power supplies for
this system have the same power output.
If mixed power supplies are installed,
the system will not operate.
For more information go to:
http://www.supermicro.com/support
Beep Code Error Message Description
1 short Circuits have been reset (Ready to power up)Refresh
5 short, 1 long Memory error No memory detected in system
5 long, 2 short Display memory read/write error Video adapter missing or with faulty memory
1 long continuous System OH System overheat condition
On Locations of (C, D), the notches
snap onto the heat sink’s
mounting holes
CPU and Processor Clip
Attaching the Processor Carrier Assembly to the Heatsink to Form the Processor Heatsink
Module (PHM)
Dust Cover
CPU Socket
Removing the Dust Cover from
the CPU Socket
Installing the Processor Heatsink Module (PHM)
Remove the dust cover from the CPU socket, exposing the
socket and socket pins as shown on the illustration below.
No : te
Do not touch the socket pins to avoid damaging
them, causing the CPU to malfunction.
Note: Do not use excessive force when tightening the screws to avoid
damaging the LGA lands and the processor.
CPU (Upside Down)
w/CPU LGA Lands up
Align Notch C of the
CPU and Notch C of
the Processor Clip
Processor Carrier Assembly (with CPU mounted
on the Processor Clip)
A
B
C
Allow carrier to
latch onto CPU
Allow carrier to
latch onto CPU
Processor Carrier Assembly
On Locations (A, B), the notches
snap onto the heatsink’s sides
Make sure Mounting
Notches snap into place
A
B
D
C
Printed Triangle Small Guiding Post
Mounting the Processor Heatsink Module
into the CPU socket (on the motherboard)
Heatsink
(Upside Down)
Triangle on the CPU
Triangle on the
Processor Carrier
Oval D
Oval C (Large Guiding Post)
12
3
4
CPU/Heatsink Package
(Upside Down)
Align Notch B of the
CPU and Notch B of
the Processor Clip
Tighten the screws in the
sequence of 1, 2, 3, 4 (top 3 quarter view)
B
C
B
C
Pin 1
A
A
Align CPU Pin 1
a
b
A
B
d
c
D
C
Socket Pins
Remove the plastic protective
cover from the CPU socket.
Do not touch or bend
the socket pins.
T30 Torx Driver
Use a torque of
12lbf-in
Features
Power button
Reset Button
Power LED
HDD LED
NIC LED
Information LED
Item
1
2
3
4
5
6
7 Overheat LED
Description
The main power switch applies or removes primary
power from the power supply to the server but
maintains standby power.
System reset button
Indicates power is being supplied to the system
power supply units.
Indicates hard disk drive activity when flashing.
Indicates network activity on the LAN when flashing.
Alerts operator to several states, as noted in the
table on the next page.
If this indicator is continuously on and red, an
overheat condition has occurred.
1
2
3
5
6
4
5
7
1 2 3 4
HDD 0
(SATA/SAS3*)
(NVMe**)
FAN 0
HDD 1
(SATA/SAS3*)
(NVMe**)
FAN 1
HDD 2
(SATA/SAS3*)
(NVMe**)
FAN 2
HDD 3
(SATA/SAS3*)
(NVMe**)
FAN 3
HDD 5
(SATA/SAS3*)
(NVMe**)
FAN 4
HDD 6
(SATA/SAS3*)
(NVMe**)
FAN 5


Product specificaties

Merk: Supermicro
Categorie: Server
Model: SuperServer 2029U-MTNRV

Heb je hulp nodig?

Als je hulp nodig hebt met Supermicro SuperServer 2029U-MTNRV stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server Supermicro

Handleiding Server

Nieuwste handleidingen voor Server