Bekijk gratis de handleiding van Silent Knight SD500-ARM (1 pagina’s), behorend tot de categorie Detector. Deze gids werd als nuttig beoordeeld door 107 mensen en kreeg gemiddeld 5.0 sterren uit 54 reviews. Heb je een vraag over Silent Knight SD500-ARM of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

SC-
33
S+
34
SC-
35
S+
36
5820 Board
Assembly
SLC Out SLC In
NC2
-SLC+
NC1 C1NO2C2 NO1
1 2 3 4 5 6 7 8
ON
Relay 1
Relay 2
Figure 1: Typical Wiring
Contacts are Form C,
non-supervised.
Power limited sources only.
Programmable relays.
This sheet is intended to be used for quick reference only. For complete information on wiring, addressing, and
programming this device, refer to the control panel installation manual.
P/N 151091 Rev D
If power-limited circuits are installed
(using types FPL, FPLR, FPLP or
other permitted substitute cables),
they must be separated from all
other conductors by a minimum of
0.25 in. or by a nonconductive
sleeve or barrier.
Model SD500-ARM Relay Module Installation Quick Reference
NC2
-SLC+
NC1 C1NO2C2 NO1
Fit screws through notches
on mounting plate. Tighten
screws to secure to box.
Figure 2: Typical Mounting
4-square electrical box
SD500-ARM circuit board
and mounting plate
(assembled at the factory)
Cover plate
45678
When attaching cover plate,
line up screw holes as shown.
Dipswitch
For device addressing.
See manual for list of
valid addresses.
LED
LED flashes green when
contacts are in normal state;
flashes red when
contacts are activated.
Supervised
Power limited
SILENT
KNIGHT
®
by Honeywell
30 VDC @ 2.0A Resistive
30 VDC @ 1.0 A Inductive (.6PF)
30 VDC @ 0.6 A (0.35PF) Pilot Duty
120 VAC @ 0.6 A (0.35PF) Pilot Duty
Operating Temperature
Operating Voltage
SLC Current
SLC Loop Resistance
Relay Ratings
For indoor use only
32° – 120°F (0° – 49°C)
24 VDC
0.55 mA
50W
Electrical & Environmental Specifications
Product specificaties
Merk: | Silent Knight |
Categorie: | Detector |
Model: | SD500-ARM |
Certificering: | UL, CSFM, MEA 429-92-E, Vol 9, FM |
Aantal per verpakking: | 1 stuk(s) |
Compatibele producten: | 6820, 6820EVS, 6808, 6700, 5820XL, 5820XL-EVS, 5808, 5700 |
Type product: | Relaismodule |
Heb je hulp nodig?
Als je hulp nodig hebt met Silent Knight SD500-ARM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Detector Silent Knight
15 Februari 2024
15 Februari 2024
14 Februari 2024
14 Februari 2024
14 Februari 2024
9 Februari 2024
Handleiding Detector
- Noyafa
- Konig
- Winland
- BlendMount
- Popp
- Rocky Mountain
- Denver
- Gossen
- SureCall
- Olympia
- Skil
- Techno Line
- ORNO
- IFM
- Laserliner
Nieuwste handleidingen voor Detector
15 Juni 2025
15 Juni 2025
12 Juni 2025
11 Juni 2025
11 Juni 2025
9 Juni 2025
7 Mei 2025
31 Maart 2025
29 Maart 2025
27 Maart 2025