Bekijk gratis de handleiding van Sauermann CO 110 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 5 mensen en kreeg gemiddeld 5.0 sterren uit 3 reviews. Heb je een vraag over Sauermann CO 110 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

1
2
3
4
5
COmeter
USER MANUAL
Description of the device
1. OK key
2. Backlight key
3. Select key
4. On/Off/Esc key
5. Hold/min/max key
CO 110
Technical specications
Measuring element C0: electrochemical sensor. Temperature: NTC
Display
4 lines, LCD technology. Dimensions 50 x 36 mm
2 lines of 5 digits with 7 segments (value)
2 lines of 5 digits with 16 segments (unit)
Connector Retractable, 0.45 m length, extension: 2.4 m
Housing ABS, protection IP54
Keypad 5 keys
European directives 2014/30/EU EMC; 2014/35/EU Low Voltage; 2011/65/EU RoHS II; 2012/19/EU WEEE
Power supply 4 batteries AAA LR03 1.5 V
Battery life 200 hours
Ambience Neutral Gas
Conditions of use (°C,%HR, m) From 0 to +50 °C. In non condensing conditions. From 0 to 2000 m.
Storage temperature From -20 to +80 °C
Auto shut-off Adjustable from 0 to 120 min
Weight 310 g
General features
Parameters Measuring units Accuracy
(1)
Measuring range Resolution
CO ppm
±3 ppm
±3% of reading
From 0 to 100 ppm
From 100 to 500 ppm
0.1 ppm
Temperature °C, °F
±0.4% of reading
±0.3 °C
From -20 to +80 °C 0.1 °C
(1)
All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

Once the measurements are frozen:
• Press “Hold/min/max”.
The device displays the maximum value of CO measured since the last questioning at the top of the screen and the
minimum value of CO measured since the last questioning at the bottom of the screen.
• Press again “Hold/min/max”.
The device displays the maximum value of temperature measured since the last questioning at the top of the screen and
the minimum value of temperature measured since the last questioning at the bottom of the screen.
• Press “On/Off/Esc” to return to the measurements display.
Display the minimum and the maximum
• Turn on the device by pressing on “On/Off/Esc”.
The device displays its name “CO 110” then performs an autozero during 5 seconds.
The probe must be left to the open-air during this autozero.
• Put the probe to the required location.
• The device displays the CO and temperature measurements.
Perform a measurement
During the measurement:
• Press “Hold/min/max” to freeze the measurement.
“Hold” appears on the screen and the measurements are frozen.
• Press “On/Off/Esc” to exit the hold function.
The device returns to the measurements display.
Freeze the measurement
Adjust the device
Device drop-down menu
During the measurement:
• Press “OK”.
“CO MAX” displays on screen with below the measuring time to adjust. This time is between 0:00 and 5:00.
• Press “Select” to adjust the rst digit then “OK” to validate, perform the same procedure for the following digits.
• When the st digit is adjusted, press “OK”.
“START” displays on screen.
• Press again “OK” to start the measuring time.
The device displays the measuring time count. At the end of this count, the CO max measurement displays on screen.
Perform a CO max measurement

Adjust the auto shut-off
The device is on and displays the measurements.
• Press “Select” until “AUTO OFF” blinks on screen.
• Press “OK”.
The time before device auto shut-off blinks on screen.
• Press “Select” to select the time before device auto shut-off: 15, 30, 45, 60, 75, 90, 105, 120 or OFF.
• Press “OK” to validate.
“AUTO OFF” blinks on screen.
• Press “On/Off/Esc” to return to the measurements display.
Activate or deactivate the keys beep
The device is on and displays the measurements.
• Press “Select” until “BEEP” blinks on the screen.
• Press “OK”.
“ON” or “OFF” blinks on the screen.
• Press “Select” to activate the keys beep “ON” or deactivate the keys beep “OFF”.
• Press “OK”.
“BEEP” blinks on the screen.
• Press “On/Off/Esc” to return to the measurement display.
Select the measuring unit in temperature
• Press “Select”.
“UNIT” blinks on screen.
• Press “OK”.
The unit currently used blinks at the bottom of the screen.
• Press “Select” until the required unit appears: °C or °F.
• Press “OK” to validate.
“UNIT” blinks on screen.
• Press “On/Off/Esc” to return to the measurements display.
Product specificaties
Merk: | Sauermann |
Categorie: | Niet gecategoriseerd |
Model: | CO 110 |
Heb je hulp nodig?
Als je hulp nodig hebt met Sauermann CO 110 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Sauermann
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
14 Augustus 2025
14 Augustus 2025
14 Augustus 2025
Handleiding Niet gecategoriseerd
- ProfiCook
- Maxsa
- InAlto
- Hoshizaki
- Barazza
- Max
- Bosch
- Calor
- Tilta
- Jupio
- Orbsmart
- Prince
- Gardena
- Bluestork
- Ednet
Nieuwste handleidingen voor Niet gecategoriseerd
16 Augustus 2025
16 Augustus 2025
16 Augustus 2025
16 Augustus 2025
16 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025
15 Augustus 2025