Bekijk gratis de handleiding van PowerWalker VI 1100 CW (18 pagina’s), behorend tot de categorie UPS. Deze gids werd als nuttig beoordeeld door 3 mensen en kreeg gemiddeld 4.5 sterren uit 2 reviews. Heb je een vraag over PowerWalker VI 1100 CW of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/18

User Manual
PowerWalker VI CW Series
Uninterruptible Power Supply System

Table of Contents
1. Important Safety Warning ................................................................................................ 1
1-1. Transportation .......................................................................................................... 1
1- Preparation 2. ............................................................................................................... 1
1- Installation 3. ............................................................................................................... 1
1- Operation 4. ................................................................................................................. 1
1-5. Maintenance, service and faults ................................................................................. 2
2. Installation And Setup ...................................................................................................... 4
2-1. Rear panel view ........................................................................................................ 4
2-2. Operating principle 5...................................................................................................
2-3. Setup the UPS .......................................................................................................... 5
3. Operations ...................................................................................................................... 7
3-1. Button operation ....................................................................................................... 7
3-2. LCD Panel 7.................................................................................................................
3-3. Audible Alarm ........................................................................................................... 8
3-4. LCD display wordings index ....................................................................................... 9
3-5. UPS Setting .............................................................................................................. 9
3-6. Operating Mode Description ..................................................................................... 12
3-7. Faults Reference Code ............................................................................................. 12
3-8. Warning indicator ...................................................................................................13
4. Troubleshooting ............................................................................................................. 14
5. Storage and Maintenance ............................................................................................... 15
6. Specifications ................................................................................................................ 16

1
1. Important Safety Warning
Please comply with all warnings and operating instructions in this manual strictly. Save this
manual properly and read carefully the following instructions before installing the unit. not Do
operate this unit before reading through all safety information and operating instructions
carefully
1-1. Transportation
Please transport the UPS system only in the original package to protect against shock
and impact.
1- Preparation2.
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please
allow at least two hours for the UPS system to acclimate the environment.
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct sunlight nearor
heater.
Do not block ventilation holes in the UPS housing.
1- Installation3.
Do not connect appliances or devices which would overload the UPS system to
the UPS output sockets.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be easily
accessible and close to the UPS system.
Please use only VDE-tested, CE-marked (or UL-marked for 110/115/120/127 VAC
models) mains cable (e.g. the mains cable of your computer) to connect the UPS
system to the building wiring outlet (shockproof outlet).
Please use only VDE-tested, -marked (or UL-marked for 110/115/120/127 VACCE
models) power cables to connect the loads to the UPS system.
When installing the equipment, it should ensure that the sum of the leakage current
of the UPS and the connected devices does not exceed 3.5mA.
Temperature Rating - Units are considered acceptable for use in a maximum
ambient of 40°C (104°F).
For Pluggable Equipment - The socket-outlet shall be installed near the equipment
and shall be easily accessible.
1- Operation4.
Do not disconnect the mains cable on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective
earthing of the UPS system and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS output
sockets or output terminals block may be electrically live even if the UPS system is not
connected to the building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to
disconnect the mains.
Prevent no fluids or other foreign objects from inside of the UPS system.
Product specificaties
Merk: | PowerWalker |
Categorie: | UPS |
Model: | VI 1100 CW |
Kleur van het product: | Zwart |
Gewicht: | 13050 g |
Breedte: | 145 mm |
Diepte: | 397 mm |
Hoogte: | 220 mm |
Geluidsniveau: | 45 dB |
Gewicht verpakking: | 13050 g |
Breedte verpakking: | 230 mm |
Diepte verpakking: | 472 mm |
Hoogte verpakking: | 325 mm |
Gebruikershandleiding: | Ja |
LED-indicatoren: | Battery replacement, Fault |
Vormfactor: | Tower |
USB-poort: | Ja |
Accu/Batterij voltage: | 12 V |
RS-232 port: | 1 |
Geluidsalarm(en): | Ja |
Responstijd: | 10 ms |
Uitgangsvermogen: | 770 W |
Batterij capaciteit: | 7 Ah |
Accu/Batterij oplaadtijd: | 4 uur |
Frequentie: | 50/60 Hz |
Power factor: | 0.7 |
Stekker: | C14 stekker |
Efficientie: | 96 procent |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 20 - 95 procent |
Type beeldscherm: | LCD |
Code geharmoniseerd systeem (HS): | 85078000 |
Aantal batterijcellen: | 2 |
Aantal AC uitgangen: | 6 AC-uitgang(en) |
Stroom (max.): | 1.4 A |
Output power capacity: | 1.1 kVA |
Ingang operation voltage (min): | 162 V |
Ingang operation voltage (max): | 290 V |
Uitgang operation voltage (min): | 208 V |
Uitgang operation voltage (max): | 240 V |
Crest factor: | 3:1 |
UPS-topologie: | Line-interactive |
Typische backup tijd op halve lading: | 3 min |
Typische backup tijd op volledige lading: | 10.9 min |
Golfvorm: | Sinus |
Noodstop-aansluiting (EPO): | Ja |
Uitgangsfrequentieregeling: | ±1 Hz |
Efficiëntie (On-line modus): | 88 procent |
Heb je hulp nodig?
Als je hulp nodig hebt met PowerWalker VI 1100 CW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS PowerWalker
22 Mei 2025
21 Mei 2025
14 April 2025
14 April 2025
14 April 2025
14 April 2025
14 April 2025
14 April 2025
14 April 2025
14 April 2025
Handleiding UPS
- MKC
- Voltcraft
- Atlantis Land
- Siemens
- Bxterra
- LC-Power
- Approx
- Lenovo
- Block
- Equip
- Eaton
- Schneider
- HP
- Dell
- Steren
Nieuwste handleidingen voor UPS
18 Juni 2025
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
8 Juni 2025
8 Juni 2025