Bekijk gratis de handleiding van PECO TB155-046 (2 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 4.3 sterren uit 2.5 reviews. Heb je een vraag over PECO TB155-046 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
1.InstalltheT155withthetwofurnishedmountingscrewstoa
standard2”x4”electricalbox,4-11/16”x2-1/8”squaredevicebox
witha2”x4”adapterringortoa4”x4”boxwithaccessoryadapter
plate.
2.Forwallinstallations,mountthethermostatonaninsidewall
approximately5feetabovetheoor.Thelocationshouldprovide
circulationataverageroomtemperature.Avoiddirectsunlightor
sourcesofhotorcoldairintheroomorwall.
3.Removetheknobandthenthecover.Mountthermostatbase
assemblytotheoutletboxusingthescrewsprovided,tightenthe
screwsevenlybutdonotovertighten.Makewiringconnectionsas
noted.
4.Tousearemotesensor,removejumperJP-1todisablelocal
sensing.FailuretoremoveJP-1whenusingaremotesensorwill
causeimproperoperationofthethermostat.Someunitsdonothave
remotesensingcapability.SeeApplicationNotes.
5.Reinstallthecoverassembly.Installcoverlockingscrewprovided.
Reinstalltheknob.
© Copyright 2010 PECO, Inc. All Rights Reserved P/N 68798 3220-1449 Rev2 Page 1
Installation Instructions
TA155/TB155
Knob Removal and Replacement
InstallatIon
•READTHESEINSTRUCTIONSCAREFULLYBEFOREATTEMPTINGTO
INSTALL,OPERATEORSERVICETHISTHERMOSTAT.
•Failuretoobservesafetyinformationandcomplywithinstructionscould
resultinPERSONALINJURY,DEATHAND/ORPROPERTYDAMAGE.
•Toavoidelectricalshockordamagetoequipment,disconnectpowerbefore
installingorservicing.
•Toavoidelectricshockordamagetoequipment,useonlywiringwithinsula-
tionratedforfullthermostatoperatingvoltage.
•Toavoidpotentialfireand/orexplosiondonotuseinpotentiallyflammableor
explosiveatmospheres.
•Retaintheseinstructionsforfuturereference.Thisproduct,wheninstalled,
willbepartofanengineeredsystemwhosespecificationsandperformance
characteristicsarenotdesignedorcontrolledbyPECO,Inc.Youmust
reviewyourapplicationandnationalandlocalcodestoassurethatyour
installationwillbefunctionalandsafe.
TemperatureRange:50°F-90°F(10°C-32°C)
TA155:AHEAT-OFF-COOLsystemswitchmanuallyselectsheating
orcoolingmode.IntheHEATposition,onlytheheatoutputcycles
withdemand.IntheCOOLposition,onlythecooloutputcycleswith
demand.IntheOFFposition,heatingandcoolingoutputsareoff.Units
withatwopositionsystemswitchorwithoutasystemswitchmustuse
aloadtransferswitchwhenbothheatingandcoolingoutputsareused.
Thispreventscontrolfailureandequipmentdamagecausedbydirect
cyclingbetweenloads.
TB155:AnON-OFFsystemswitchenablesauto-changeoverofheating
andcoolingmodes.IntheONpositionthethermostatactivatesheating
orcoolingoutputsdependantupontherelationshipbetweensetpoint
andambienttemperature.Heatontocoolondeadbandis4°F.In
theOFFposition,heatingandcoolingoutputsareoff.Unitswithout
asystemswitchcyclebetweenheatingandcoolingwitha4°Fdead
band.
FAN:Someunitshaveaswitchformanualselectionoffanspeed.On
theseunitsfanoperationiseitherinternallywiredforfancontinuous
operationorisdependantuponconnectiontothefansupplyinput.
Wheninternallywiredforfancontinuousoperation,thefanwillbe
offwhenthesystemswitchisoff.Whendependantuponexternal
connectionsthefanmaynotbeoffwiththesystemswitchintheoff
position.Thefansupplyinputisswitchedtofanspeedoutputs(HI-
MED-LO).
SWITCHEDPOWER:L1powerisswitchedtothisoutputanytimethe
systemswitchisoutoftheOFFposition.
tHeRmostat opeRatIon
Whenremovingandre-installingtheT-155
knob,caremustbetaken.
•Alignarrowto70°Fontheknob(22C)or
midrangewhenremovingtheknob.
•Reinstallknobbyaligningarrowto70°F
(22C)ormidrange.
•Donotforceit.Whenproperlyaligned,the
knobwillslipintoposition.
Align arrow to 70°F
on the knob (22C)
•UseCopperwire
only,insulateorwire
nutallunusedleads.
•Anywiring,including
theremoteprobe,
maycarrythefull
operatingvoltageof
thethermostat.
caUtIon
!
caUtIon
!
WaRnInG
!
© Copyright 2010 PECO, Inc. All Rights Reserved P/N 68798 3220-1449 Rev2 Page 2
WhitewithOrangeStripe   FanHigh
WhitewithRedStripe   FanMedium
WhitewithBrownStripe   FanLow
Red     Heat
Blue     Cool
Black     L1
Yellow     L2orNeutral
Orange     SwitchedPower
Violet     FanSupply
Brown     RemoteProbe1
Brown     RemoteProbe2
     *Ifapplicable


1.Tousearemotesensor,removejumperJP-1todisablelocalsensing.



2.Remoteprobewiringshouldbelocatedawayfromanyelectrical
motorsorpowerwiring
3.Someunitsareinternallywiredforpermanentfancontinuous
operation.
4.OnunitswithaFanSupplyinputtheoperationofthefanis
determinedbywiringconnection.Forfancontinuous,jumpertheFan
Supplyinput(TB2-5)totheSwitchedPoweroutput(TB3-3).
5.Forfancyclingoperationwithacallforheatorcool,afanrelaymust
beused.
6.Observeelectricalratings.Thermostaticoutputsarepilotdutyonly.


Voltage
Rating
Inductive
FLA LRA
Resistive
Amps
Pilot
Duty
Thermostatic
Switching
24 VAC
120 VAC
240 VAC
277 VAC
N.A. N.A. N.A. 24 VA 10 VA
5.8 34.8 6.0 125 VA 20 VA
20 VA
20 VA
125 VA
125 VA
2.9 17.4 5.0
2.4 14.4 4.2
FAN AND SYSTEM SWITCHES



Product specificaties

Merk: PECO
Categorie: Thermostaat
Model: TB155-046

Heb je hulp nodig?

Als je hulp nodig hebt met PECO TB155-046 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat PECO

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat

MKC

MKC MKTI-1014 Handleiding

2 September 2025
MKC

MKC MKTI-1020 Handleiding

1 September 2025
Avidsen

Avidsen HomeTap Handleiding

30 Augustus 2025
Pro1

Pro1 T701 Handleiding

26 Augustus 2025
Pro1

Pro1 T855iSH Handleiding

26 Augustus 2025
Vimar

Vimar 03989 Handleiding

26 Augustus 2025
Carrier

Carrier TB-TM Handleiding

26 Augustus 2025
Pro1

Pro1 T715 Handleiding

26 Augustus 2025