PCE Instruments PCE-DC2 Handleiding


Bekijk gratis de handleiding van PCE Instruments PCE-DC2 (9 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 5 mensen en kreeg gemiddeld 4.9 sterren uit 3 reviews. Heb je een vraag over PCE Instruments PCE-DC2 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/9
PCE Americas Inc.
711 Commerce Way
Suite 8
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
www.pce-instruments.com/english
www.pce-instruments.com
Manual
Current clamp PCE- DC2
Version 1.2
Date of creation: 16.02.2015
Date of last change: 05.07.2022
Manual
2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
3 Specication ............................................................................................................ 4
3.1 Technical specications .............................................................................................................. 4
3.2 Contents of delivery .................................................................................................................... 4
4 System description ................................................................................................. 6
4.1 Battery replacement ................................................................................................................... 6
5 Measuring ................................................................................................................ 6
5.1 AC current measurement ........................................................................................................... 6
5.2 DC current measurement ........................................................................................................... 7
5.3 AC/DC voltage measurement ..................................................................................................... 7
5.4 Non-contact voltage test ............................................................................................................. 7
5.5 Resistance measuring and continuity test .................................................................................. 7
6 Additional functions 7 ................................................................................................
6.1 Flashlight .................................................................................................................................... 7
6.2 Display backlight ......................................................................................................................... 8
6.3 Display hold ................................................................................................................................ 8
6.4 Peak ............................................................................................................................................ 8
6.5 Max/Min function ........................................................................................................................ 8
6.6 Zeroing of DC currents ............................................................................................................... 8
6.7 off Auto power- ............................................................................................................................ 8
7 Contact ..................................................................................................................... 9
7.1 PCE Instruments UK .................................................................................................................. 9
7.2 PCE Americas ............................................................................................................................ 9
Manual
3
1 Introduction
Thank you for purchasing a current clamp from PCE Instruments.
With the current clamp PCE-DC2 you can measure AC/DC voltages and currents, as well as the electrical
resistance. The clamp mechanism of the PCE-DC2 enables you to perform non-contact current
measurements, while voltage and resistance measurements can be done by using the included test
leads. Due to its compact design, the current clamp is well-suited for mobile application. With its built-in
ashlight and the display with backlight, the current clamp can even be operated in areas with poor
lighting conditions.
2 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
The device may only be used approved temperature humidity range. in
The device should not lay face down on the workbench or work surface to avoid damage to the
controls.
Avoid strong shocks.
Always keep the device clean and dry.
The appliance should only be cleaned with a damp cloth / use only -neutral cleaner. pH
Do not make any technical changes to the current probe.
The opening of the device and maintenance or repair work should only be done by qualied service
personnel of the PCE Instruments.
Before starting the measurement mode, the device should be stabilized to the ambient temperature.
Before each measurement, the device should be checked for damage.
Do not use the measuring clamp in the presence of ammable gases, vapours or solvents.
The device is intended for the use of interior spaces.
This user's handbook is published from PCE Instruments without any guarantee.
We expressly point to our general guarantee terms, they can be found in our general terms of business.
If you have any questions please contact PCE Instruments.


Product specificaties

Merk: PCE Instruments
Categorie: Meetapparatuur
Model: PCE-DC2

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-DC2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden