INSTRUCTION Manual DC850R - 3/6/2018
WARNING: When a flammable liquid is sprayed, there
may be danger of fire or explosion especially in a closed
room. Keep compressor at least 20 feet away from
areas where hazardous concentrations of flammable
vapors are likely to occur. Disconnect power before
servicing.
ATTENTION: Lorsqu'un est liquide inflammable pulverise,
il peut y avoir danger d'incendie ou d'explosion,
specialement dans une piece fermee; garder le
compresseur a moins 20 ou au pieds des endroits des
concentrations dangereuses de vapeurs inflammables
sont de se susceptibles produire. Debrancher avant toute
maintenance.
DC 50R Pro Series8
Air Compressor
3/4 HP, 120 Volts, 60 Hz,
Max Operating Pressure 100 PSI.
Weight: 36.3 lbs (16.5 kg)
Features:
•Portable & Lightweight
•Ultra Quiet 58 Decibels
•Thermally Protected
•
•
Steady Air Flow
•Auto Stop and Start
•1/4” NPT Fittings
•Carrying Handle
Compressor Specs:
Operation Instructions:
1)
2)
3)
4)
5)
• Dual Piston / Oil Free
• 3/4 HP
• 110-120 Volt /60HZ 5.5 Amps
• 100 Max Pressure
• 2.40 CFM @ 40psi
1.50 CFM @ 90 psi
•Tank Size: 6L =1.585 Gallons
• 36 (16.3kg)lbs
• Dim: 17”L 13”Hx 14”W x
• 5 Foot Electric Cord
•Dual Quick Connects
Before operating Compressor, Install Muffler on compressor head
"Hand tight" with drain hose facing down.
Apply PTFE pipe tape (Included) to male thread of Quick connect
(Included). Thread onto 1/4"Airbrush hose end. Attach airbrush to
1/8" hose end.
Plug compressor into grounded outlet, pull up on red button on black box.
When compressor stops, press trigger on airbrush and hold down while
turning large red air regulator clockwise to increase air, or counterclockwise to
decrease air. When gauge reaches desired pressure release trigger.
Turn off compressor after use and loosen drain valve at bottom of
compressor to empty out any standing water in tank .
PAASCHE
Regulator
GENERAL & SAFETY INFORMATION
GENERAL INFORMATION
The the The maximum pressure of compressor is 0-100 PSI . maximum operating pressure while spraying will vary
depending on size and of tip, fluid needle aircap.
THERMAL PROTECTOR
The compressor motor of this has
a overload If the thermal protector.
motor should overheat, the
overload protector will shut off the
motor. occur, If this should unplug
the compressor and allow the motor
to 5 minutes) and cool (approx.
restart compressor.
SEALING OF AIR HOSE
When attaching the female pipe
thread hose fitting from your air to
the compressor use PTFE pipe
thread tape (Included) on the Male
quick connect. Failure to do so may
cause leak and an air your
compressor will not shut as off it
should. NOTE: This unit does not
require any lubricants or oil. Applying
oil could to any part result in damage
to the compressor. All bearings,
including those in the motor, are
grease packed.
AUTOMATIC SHUT-OFF FEATURE
This compressor has a built-in
pressure switch that automatically
shuts-off the the compressor when
tank is full. It immediately will start
again as as soon the tank reaches the
pre-set psi.
WARNINGS
• Only use 110-120 volt, 60 cycle power supply for this compressor.
• Before plugging in check to make sure compressor is in good condition.
• Only operate compressor in accordance with current safety regulations.
• Keep working area clean and uncluttered and make sure area is well ventilated. Never operate the compressor in the presence of
flammable liquids or gases.
• Compressor air can produce dust, dirt and loose particles it comes in contact with. To prevent possible injury always wear safety
goggles or glasses. Never point any nozzle or spray toward a person.
• The air compressor is powered by Like any electric if not used properly it can cause electric electricity. device, shock.
• Keep out of reach of children.
Suggested Accessories:
1) QM-2/QM-4 Formanifolds.
multiple hose hook ups.
2) Hose adapter. hose your If has
a get 1/8” NPT fitting the HF-592.
For the opposite get HF-116.
3) A-194 Airbrush Holder
4)
Manufactured in China for Paasche
Paasche Airbrush Company
9511 58th Place
Kenosha, WI 53144
Phone: (800) 621-1907
Website: paascheairbrush.com
E-Mail: info@paascheairbrush.com
This compressor is CE Listed
Included male
quick connects
Air
Regulator Tank pressure
gauge
Air outlet gauge
Muffler
Tank
Moisture
drain valve
Pull- .....Push-ON OFF
AC-7 Airbrush Cleaning Brushes


Product specificaties

Merk: Paasche
Categorie: Niet gecategoriseerd
Model: DC850R

Heb je hulp nodig?

Als je hulp nodig hebt met Paasche DC850R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Paasche

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd