Optex FX-360 Handleiding

Optex Detector FX-360

Bekijk gratis de handleiding van Optex FX-360 (2 pagina’s), behorend tot de categorie Detector. Deze gids werd als nuttig beoordeeld door 55 mensen en kreeg gemiddeld 4.6 sterren uit 3 reviews. Heb je een vraag over Optex FX-360 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
I.INSTALLATIONHINTS
IX.SPECIFICATIONS
II.DETECTIONAREA
CeilingMountType360°PIRDetector.
PASSIVEINFRAREDDETECTOR
Installwithin8-12ft.(2.4-3.6m)height
fromfloor.
(2.4-3.6m)
AvoidCurtain,Screen,etc.blocking
detectionarea.
Donotinstalloutdoor.
TOPVIEW
FEATURES
SIDEVIEW
Installation
Height
ft(m)
PassiveInfrared
inches(mm)
inches(mm)
Thenixsignindicatesprohibition.
Dimensions
MountingPosition
ø25ft-ø40ft/(ø8m-ø12m)
Height8ft-12ft/(2.4m-3.6m)
62zones
3°F(1.6°C)at2ft./sec.(0.6m/sec.)
1-5ft./sec.(0.3-1.5m/sec.)
LEDisblinkingduringwarm-upperiod.
Alarmindicatoroptional
2.0±0.5sec.
20±5sec.2or4
Approx30sec.(LEDblinks.)
9.5-18VDC
17mAat12VDC/(normal)
18mAat12VDC/(max.)
4.9oz(140g)
‒4°F-+122°F(‒20°C-+50°C)
95%max.
NoAlarm20V/m
N.C.28VDC0.2Amax.
N.C.30VDC0.1Amax,Openswhencoverremoved.
Detectionmethod
Coverage
Detectionzones
Sensitivity
Detectablespeed
LEDindicator
Alarmperiod
Alarmoutput
Tamperswitch
PulseCount
Warmupperiod
Powerinput
Currentdraw
Weight
Enviromentalhumidity
RFIinterference
Operating
temperature
MAX.DetectionAREA
8
(2.4)
25
(8)
32
(10)
40
(12)
10
(3)
12
(3.6)
Detection
Area
(Diameter)
ft(m)
Selectablepulsecount2or4.
LEDON/OFFremotelyfromthecontrolpanelorthedetector.
FX-360
ø4.72(ø120)
3.23(82)
ø3.29(ø83.5)
ø0.18(ø4.5)
ø0.18(ø4.5)
ø0.33(ø8.5)
R1.46(R37)
ø0.28(ø7)
WallTamper
21°
1
45°
MountingSubHole
0
H
ft(m)
8(2.4)
10(3)
12(3.6)
Dft(m)
20(6)
)12.5(4)20(6)2(5.6)2(5.612.5(4)0
MountingHole
1.02(26)
0.98(25)
0.24(6)
WiringKnockout
0.6(15)
08(25).9
1.46(37)
No.59-3472-12405-07
UL59-0523-40908-31
NOTE
12.5(4)
20(6)
6.5(2)
0
6.5(2)
12.5(4)
20(6)
INAANNNSSTLLTIO ISTTIORUC
Avoid direct sunlight.
Avoid facing directly
to air conditioners or
heating vents.
Avoid vapor or high humidity that can
cause condensation.
Ts it is desied to detect an intruder and activate an alarm control nel. hiungnpa
Being only a part of a comete system, we cannot accept responsility for plbi
any mages or otr coces tg from an intrion.dahensequenresulinus
EN
- 1 -- 4 -
ModelFX-360
EU & UK contact information
https://navi.optex.net/cert/contact/
OPTEX INC./ HQ (U.S.)AMERICAS
www.oexamerica.compt
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-eure.comop
OPTEX B.V. SECURITY
(The Netherlds)an
wwoptex-europe.com/nlw.
OPTEX SECURITY SAS (Frce)an
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Pold)an
wwoptex-europe.com/w.pl
OPTEX PINNACLE INDIA,
PVT., LTD. (Iia)nd
www.optexpinnacle.com
OPTEX KEA CO.,LTD. (Korea)OR
www.oexkorea.compt
OPTEX (DOGUAN) CO.,LTD.NG
SHANGHAI OFFICE (Cna)hi
www.oexcha.comptin
OPTEX (Tild) CO., LTD. (Tild)haanhaan
www.optex.co.th
Copyright (C) 1992-20 OPTEX CO.,LTD.24
OPTEX ., LTD. ()COJAPAN
www.oexpt.net
PD6662:2017
ULListed
COMPLIANCE
EN50131-2-2SecurityGrade2,EnvironmentalClassII
testedandcertificatedbyKiwaB.V.

Beoordeel deze handleiding

4.6/5 (3 Beoordelingen)

Product specificaties

Merk: Optex
Categorie: Detector
Model: FX-360

Heb je hulp nodig?

Als je hulp nodig hebt met Optex FX-360 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden