Bekijk gratis de handleiding van Oliveri Essente SS31675 (2 pagina’s), behorend tot de categorie Kraan. Deze gids werd als nuttig beoordeeld door 10 mensen en kreeg gemiddeld 4.8 sterren uit 5.5 reviews. Heb je een vraag over Oliveri Essente SS31675 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Installation Instructions
Technical Data
THIS MIXER TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS.
This Oliveri tap is manufactured to standard AS/NZS 3718.
Before attempting any work involving mains water supply lines, ensure the water supply is
shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri mixer to allow
isolation (not supplied with mixer). Failure to do so where required will void warranty.
This mixer tap is already pre-assembled and tested. Do not disassemble, as this may void
This mixer tap must be installed in accordance with these instructions.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena R
d, Regency Park SA 5010 P 08 8348 6444 E sales@oliveri.com.au
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure.
Note:
Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent
removal by hand.
Note:
Ceramic Cartridges - Warranty claims will not be honoured where the ceramic
cartridge has malfunctioned due to the presence in the water supply of;
Copper tube pieces, sand, dirt or stones
Thread tape
Other objects not normally present in potable water supplies.
Do not remove the cartridge from the body as it has been pressure tested and
tightened to a specific torque.
MAX OPERATING PRESSURE: ...................................................... 5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE: ................................... 1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE: ............................................. 65°C
RECOMMENDED HOT WATER TEMPERATURE: ............................ 50°C
TF 185 - SS 75 Installation Instructionse 316
Essente
Stainless Steel Square Goose Neck Pull Out Mixer
SS 75316 / SS 75-AU / SS 75-BL / SS 75-GM 316 316 316 / SS31675-CU
CARE & MAINTENANCE
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water
pressure. The finish on your Oliveri mixer tap will resist stains and dirt build up.
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning.
Avoid using abrasive or acid based cleaning products.
WARRANTY FOR DOMESTIC USE
This mixer tap is warranted to be free from manufacturing defects for a period of
1 Years: Cartridge: 1 years replacement parts, 1 year labour; Body including handle: 5 5
7 years replacement parts and labour; Finish: 5 years replacement parts, 1 year labour;
Seals, tails, aerators, pull-out hoses and spray heads: 1 year replacement parts and labour.
Where a genuine manufacturing defect arises within the warranty period Oliveri will, at
its election, repair the defect or replace the product subject to the terms contained in the
full warranty information available at https://oliveri.com.au/service-and-warranty.
This warranty does not cover against normal wear and will be voided if the
product is misused or no installed in accordance with these instructions. t Note:
Fitting spout-attached devices, including water filters, to this mixer will void warranty.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur,
immediately shut off the water supply. If the mixer tap requires servicing, please
contact your plumber (preferably the one who installed it). Most problems occur due to
contaminated supply lines or water pressure exceeding 500kPa. Unscrew and clean the
spout aerator periodically - especially if you notice a drop in water pressure.
If the plumber / installer is satisfied that the problem is not due to poor installation,
contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: (08) 8348 6444 (choose the after sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
This product complies with the Lead Free requirements of the National
Construction Code Volume 3.
Installation Instructions
TF 185 - SS 75 Installation Instructionse 316
A
C
D
E
F
G
J
I
H
B
Max 37
K
PRESSURES & TEMPERATURES
Ma
ximum Hydrostatic Pressure – 500kPa. (As per AS/NZS3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that
”Provision shall be made to ensure that the maximum static
pressure at any outlet, other than a fire service outlet, within a building does not exceed 500kPa.
Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances, taps
and fittings, and cause excessive noise in the system. Minimum Hydrostatic Pressure 100kPa. :
Note: This Product may not be suitable for use with low pressure/gravity feed water supplies or with
some continuous flow/instantaneous hot water systems. The maximum operating temperature for the
Mixer Tap is 65ºC. The recommended maximum delivery temperature is 50ºC.
Please ensure that the lines are flushed prior to installation as contaminates in the water can
damage the Ceramic Cartridge, flow regulator and also affect the performance of the Mixer.
Note: This mixer is designed to have the handle to the right hand side of the mixer, doing so will put
the cold inlet to the front of the mixer, the purpose is to assist with accidental scalding if a child pulls
the handle forward trying to turn on the mixer, installing the handle to the centre will put the cold on
the left hand side which is not recommended.
1. Remove product from packaging and check for damages, if the product is damaged do not install
and return to store of purchase.
2. The WELS compliant aerator has been pre-assembled into the mixer outlet. To comply with
WELS the
flow regulated aerator must remain in place.
3. Ensure product is complete as per exploded drawing.
4. A single 35mm hole is required in the mounting surface.
5. The maximum mounting surface thickness cannot exceed 37mm.
6. Fit O-ring (A) to bottom of mixer body.
7. Screw Mixer Tails (B) into the base of the mixer being careful not to damage to the O-ring seals. Hand
tighten only.
8. Feed male end of Braided Hose (H) through top of mounting surface.
N.B. Hose Adaptor (J) and Washer (I) are lightly screwed to male end of Hose (H), this fitting will
need to be removed for ease of feeding hose through mounting surface.
9. Feed the Mixer Tails (B) through the mounting surface, each tail alternatively.
10. The mixer inlet ports are colour coded, red for hot and blue for cold.
11. Position mixer on the mounting surface ensuring the Sealing Washer (A) is positioned correctly.
12. Feed mixer tails, each alternatively through Stabiliser Plate (C).
13. Slide Rubber Washer (D) onto mixer thread followed by Metal Washer (E).
14.Using Fixing Nut (F), tighten mixer to mounting surface, lock fixing nut in place with Screws (G).
15.Screw Hose Adaptor (J) to male threaded end of Hose (H) ensuring Sealing Washer (I) is in place.
16. O-ring seals.Screw Hose Adaptor (J) to Mixer Water Outlet port being careful to avoid damage to the
17.
18.
Connect Mixer tails (B) to mains water 1/2"stop cock. Tighten to 10Nm. Do NOT overtighten.
N.B. Ensure the Mixer Tails are not kinked, bent, stretched or twisted when assembling to
the mains water supply. The mixer tail connection between the mixer and the water supply
must have a natural curve (minimum bend radius 30 mm). Ensure Mixer tails are installed
indoors, above-ground, and remain accessible - do not bury, submerge, install behind a wall, floor or
ceiling. Do not not expose to abrasions, corrosive agents or the like. Test for leaks: If a leak occurs,
retighten slightly.
19.It is recommended that in-line filters be installed to ensure a cleaner flow of water to the mixer.
20.The Braided hose will have a natural curve under the mounting surface, on the hand piece side of the
curve fit the Return Weight (K) using the two screws provided. Fit the weight approximately 100mm
up from the bottom of the curve, the position can be adjusted to suit but the weight must remain on
the hand piece side of the curve.
TO THE CONSUMER
1. The mixer is to only be cleaned with warm soapy water.
2. Under no circumstances should any abrasive, cream or acid based cleaning agents be used
as these types of cleaners will damage the tap finish, cartridge, seals and aerators.
GENERAL NOTE
This product is to be installed by
a licensed plumber, installation
must comply with AS/NZS 3500
and local plumbing codes.


Product specificaties

Merk: Oliveri
Categorie: Kraan
Model: Essente SS31675

Heb je hulp nodig?

Als je hulp nodig hebt met Oliveri Essente SS31675 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden