Bekijk gratis de handleiding van Oliveri Essente SS31615 (2 pagina’s), behorend tot de categorie Kraan. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 3.8 sterren uit 3.5 reviews. Heb je een vraag over Oliveri Essente SS31615 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Technical Data
Installation Instructions
TF 180 - SS2515 nstallation nstructions.pdfbI I
Essente
Stainless Steel Swivel Pull Out Mixer
SS2515
CARE & MAINTENANCE
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water
pressure. The finish on your Oliveri mixer tap will resist stains and dirt build up.
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning.
WARRANTY FOR DOMESTIC USE
This mixer tap is warranted to be free from manufacturing defects for a period of
10 Years: Cartridge: 10 years replacement parts, 1 year labour; Body including handle:
7 years replacement parts and labour; Finish: 5 years replacement parts, 1 year labour;
Seals, tails, aerators, pull-out hoses and spray heads: 1 year replacement parts and labour.
Where a genuine manufacturing defect arises within the warranty period Oliveri will, at
its election, repair the defect or replace the product subject to the terms contained in the
full warranty information available at https://oliveri.com.au/service-and-warranty.
This warranty does not cover against normal wear and will be voided if the
product is misused or not installed in accordance with these instructions. Note:
Fitting spout-attached devices, including water filters, to this mixer will void warranty.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur,
immediately shut off the water supply. If the mixer tap requires servicing, please
contact your plumber (preferably the one who installed it). Most problems occur due to
contaminated supply lines or water pressure exceeding 500kPa. Unscrew and clean the
spout aerator periodically - especially if you notice a drop in water pressure.
If the plumber / installer is satisfied that the problem is not due to poor installation,
contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: (08) 8348 6444 (choose the after sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
THIS MIXER TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS.
This Oliveri tap is manufactured to standard AS/NZS 3718.
Before attempting any work involving mains water supply lines, ensure the water supply is
shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri mixer to allow
isolation (not supplied with mixer). Failure to do so where required will void warranty.
This mixer tap is already pre-assembled and tested. Do not disassemble, as this may void
the warranty.
This mixer tap must be installed in accordance with these instructions.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena Rd, Regency Park SA 5010 P 08 8348 6444 E sales@oliveri.com.au
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure.
Note:
Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent
removal by hand.
Note:
Ceramic Cartridges - Warranty claims will not be honoured where the ceramic
cartridge has malfunctioned due to the presence in the water supply of;
Copper tube pieces, sand, dirt or stones
Thread tape
Other objects not normally present in potable water supplies.
Do not remove the cartridge from the body as it has been pressure tested and
tightened to a specific torque.
MAX OPERATING PRESSURE: ...................................................... 5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE: ................................... 1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE: ............................................. 65°C
RECOMMENDED HOT WATER TEMPERATURE: ............................ 50°C
Installation Instructions
1. Remove product from packaging and check for damage, if the product is damaged do not
install and return to store of purchase.
2.
The mpliant er WELS co aerator has been pre-assembled into the mix outlet. To comply with
WELS he flow regulated aerator must remain in place. t
3. Ensure Product is complete per explod drawing. as ed
4. A single 35mm Hole is required in the mounting surface.
5. The d maximum mounting surface thickness cannot excee 37mm.
6. Fit Rubber washer (A) to bottom of mix body.er
7. Screw the Mixer tails (B) into base of the Mixer being careful to avoid d to the oring seals amage
8. Feed Male end of braided hose (H) through top of mounting surface.
Note: Hose tingAdaptor (J) & Washer (I) are lightly screwed to male end of Hose (H), this fit
will need to removed for ease of feeding hose through mounting surface.
9. Feed the Mixe tails (B) through the mounting surface, each Tail alternatively.r
10. The Mixer inlet ports are colour coded, red for hot and blue for cold.
11. Position he ixer n the unting urface nsuring he ealing washer A) s positioned t M o mo s e t s ( i
correctly.
12. Feed Mixer tails, each alternatively through Stabiliser Plate (C).
13. Slide Rubber Washer (D) onto Mixer thread followed by Metal Washer (E).
14. Using Fixing Nut (F tighten Mixer to mounting su ) rface, lock Fixing Nut in place with screws (G).
15. Screw adaptor (J) to Male threaded end of hose (H) ensuring s w (I) is in Hose ealing asher
place.
16. Screw hose adaptor (J) to Mixer Wat Outlet port being careful to avoid damage to the er
o’ring seals.
17. Connect Mixer tails (B) to mains water supply line.
18. N.B Ensure the Mixer tails are not kinked, bent, stretched or wis when t ted
assembling to the mains water supply. The Mixer Tail connection between the
mixer and the water must have natural curve. supply a Ensure Mixer tails are not
exposed to abrasions, corrosiv agents or the like e .
19. It is recommended that in-line filters be installed to ensure a cleaner flow of water to the Mixer.
20. The Braided hose will have a natural curve under the mounting surface, on the hand piece
side of the curve fit the Return Weight (K) using the tw screws provided. Fit the weight o
approximately 100mm up from the bottom of the curve, the position can be adjusted to
suit weight must remain on the hand piece side of th curve. the but e
TF 180 - SS2515 nstallation nstructions.pdfbI I
PRESSURES & TEMPERATURES
Maximum Hydrostatic Pressure 500kPa. (As per AS/NZS 3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that ”Provision shall be made to ensure that
the maximum static pressure at any outlet, other than a fire service outlet, within a building does
not exceed 500kPa.” Pressures above 500kPa can cause damage from water hammer, Note:
reduced life of appliances, taps and fittings, and cause excessive noise in the system. Minimum
Hydrostatic Pressure – 100kPa. The Maximum operating temperature for the Mixer Tap is 65ºC.
Please ensure that the lines are flushed prior to installation as contaminates in the
water can damage the Ceramic Cartridge, flow regulator and also affect the
performance of the Mixer.
TO THE CONSUMER
1. The mixer is to only be cleaned with warm soapy water.
2. should any abrasive, cream or acid based cleaning agents be usedUnder no circumstances
as these types of cleaners will damage the tap finish, cartridge, seals and aerators.
A
C
J
I
H
B
Max 37
D
E
F
G
K
GENERAL NOTE
This product is to be installed by
a licensed plumber, installation
must comply with AS/NZS 3500
and local plumbing codes.