Bekijk gratis de handleiding van Oliveri Essente SS31670 (2 pagina’s), behorend tot de categorie Kraan. Deze gids werd als nuttig beoordeeld door 35 mensen en kreeg gemiddeld 4.9 sterren uit 4 reviews. Heb je een vraag over Oliveri Essente SS31670 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Technical Data
Installation Instructions
TF 184 - SS70 installation instructions.pdfd316
Essente
Stainless Steel Goose Neck MixerSquare
SS31670/ SS31670-AU / SS31670-BL / SS31670-GM
CARE & MAINTENANCE
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water
pressure. The finish on your Oliveri mixer tap will resist stains and dirt build up.
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning.
Avoid using abrasive or acid based cleaning products.
WARRANTY FOR DOMESTIC USE
This mixer tap is warranted to be free from manufacturing defects for a period of
1 Years: Cartridge: 1 years replacement parts, 1 year labour; Body including handle: 55
7 years replacement parts and labour; Finish: 5 years replacement parts, 1 year labour;
Seals, tails, aerators: 1 year replacement parts and labour.
Where a genuine manufacturing defect arises within the warranty period Oliveri will, at
its election, repair the defect or replace the product subject to the terms contained in the
full warranty information available at https://oliveri.com.au/service-and-warranty.
This warranty does not cover against normal wear and will be voided if the
product is misused or not installed in accordance with these instructions. Note:
Fitting spout-attached devices, including water filters, to this mixer will void warranty.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur,
immediately shut off the water supply. If the mixer tap requires servicing, please
contact your plumber (preferably the one who installed it). Most problems occur due to
contaminated supply linesor water pressure exceeding 500kPa. Unscrew and clean the
spout aerator periodically - especially if you notice a drop in water pressure.
If the plumber / installer is satisfied that the problem is not due to poor installation,
contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: (08) 8348 6444 (choose the after sales service and warranty option)
Email: [email protected]
For full warranty information visit: https://oliveri.com.au/service-and-warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
THIS MIXER TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS.
This Oliveri tap is manufactured to standard AS/NZS 3718.
Before attempting any work involving mains water supply lines, ensure the water supply is
shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri mixer to allow
isolation (not supplied with mixer). Failure to do so where required will void warranty.
This mixer tap is already pre-assembled and tested. Do not disassemble, as this may void
the warranty.
This mixer tap must be installed in accordance with these instructions.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena Rd, Regency Park SA 5010 P 08 8348 6444 E sales@oliveri.com.au
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure.
Note:
Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent
removal by hand.
Note:
Ceramic Cartridges - Warranty claims will not be honoured where the ceramic
cartridge has malfunctioned due to the presence in the water supply of;
•Copper tube pieces, sand, dirt or stones
•Thread tape
•Other objects not normally present in potable water supplies.
Do not remove the cartridge from the body as it has been pressure tested and
tightened to a specific torque.
MAX OPERATING PRESSURE:......................................................5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE:...................................1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE:.............................................65°C
RECOMMENDED HOT WATER TEMPERATURE:............................50°C
This product complies with the Lead Free requirements of the National
Construction Code Volume 3.
Product specificaties
| Merk: | Oliveri |
| Categorie: | Kraan |
| Model: | Essente SS31670 |
Heb je hulp nodig?
Als je hulp nodig hebt met Oliveri Essente SS31670 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Kraan Oliveri
18 September 2025
15 Mei 2025
15 Mei 2025
15 Mei 2025
15 Mei 2025
15 Mei 2025
7 April 2025
7 April 2025
1 April 2025
1 April 2025
Handleiding Kraan
Nieuwste handleidingen voor Kraan
14 Januari 2026
14 Januari 2026
13 Januari 2026
13 Januari 2026
13 Januari 2026
13 Januari 2026
13 Januari 2026
12 Januari 2026
12 Januari 2026
12 Januari 2026