NightStick XPP-5466 Handleiding
NightStick Lamp XPP-5466
Bekijk gratis de handleiding van NightStick XPP-5466 (3 pagina’s), behorend tot de categorie Lamp. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.2 sterren uit 2 reviews. Heb je een vraag over NightStick XPP-5466 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/3

Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • USA • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com
INS-XPP-5466-LG-21
11-11-2020
INSTALLING THE FORTEM ON TO THE HELMET
Image 4Image 5
yChoose the side of the helmet you wish to mount the light on.
yRotate the mount to orient the clamp with thumbscrew on top.
yOpen the clamp completely and fully seat over helmet brim, ensuring the clamp clears any
rubber helmet trim. (Image 4)
yTighten the clamp rmly with included Allen wrench. (Image 5)
SCAN FOR
MOUNTING
INSTRUCTION
VIDEO
https://youtu.be/Ta0i7U-92hM
SETTING THE ANGLE OF THE LIGHT
yTwist the light left or right on the vertical pivot until beam pattern is in an ideal position.
yThe tension on the mount is meant to be rm to maintain the aim.
yOnce aimed, the mount allows the user to position light above or below the brim by rotating
up or down as needed.
OPERATION
The FORTEM has seven lighting modes:
yConstant-on high-brightness ashlight
yMedium-brightness ashlight
yLow-brightness ashlight
yConstant-on high-brightness oodlight
yMedium-brightness oodlight
yLow-brightness oodlight
yConstant-on Dual-Light mode
The FORTEM has two switches, the ashlight switch (closest to the front of the light) and
the oodlight switch (closest to the rear of the light) providing access to all modes.
CONSTANT-ON FLASHLIGHT
Press the ashlight switch (closest to the front of the light) until it clicks and then release
for constant-on ashlight in high-brightness mode. Press and release this same switch again
to turn the light off.
SELECT FLASHLIGHT BRIGHTNESS LEVEL
Press and hold down the ashlight switch. The ashlight will cycle from high to medium
to low and then back up again at a rate of approximately one mode per second. The light will
continue to cycle up and down through the various modes as long as the ashlight switch is
held down. When the desired brightness level is reached, simply release the ashlight switch,
and the light will remain in that brightness mode. Pressing and holding the ashlight switch
again will cause the light to cycle from whatever mode it is currently in. Press and release the
ashlight switch to turn the light off.
CONSTANT-ON FLOODLIGHT
Press the oodlight switch (closest to the rear of the light) until it clicks and then release
for constant-on oodlight in high-brightness mode. Press and release this same switch again
to turn the light off.
Instruction Manual
FORTEM
®
XPP-5466
US PATENT 9,713,217 AND 11,019,868
THE XPP-5466 IS APPROVED FOR USE
CLASS I DIV 1 GRPS A-D T4
CLASS II & III DIV 1 GRPS E-G T135°C
CLASS I ZONE 0 AEx ia IIC T4 Ga
CLASS I ZONE 0 Ex ia IIC T4
-20ºC ≤ Tamb ≤ +40ºC
3.0V/Cell / Energizer 123
E 467756
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
Conforms to:
ANSI/UL STD 913, ANSI/UL 60079-0
Certified to:
CAN/CSA STD C22.2 No 157
CAN/CSA STD C22.2 No 60079-0
CAN/CSA STD C22.2 No 60079-11
CSA STD C22.2 No 25
Bayco Products, Inc. XPP-5466
WARNINGS:
Do not change batteries in hazardous location.
Use only Energizer 123 Batteries
ID 5012927
WARNINGS - INTRINSICALLY SAFE
yWarning: Use only the approved non-rechargeable batteries listed below.
yWarning: Do NOT attempt to use rechargeable CR123A batteries with this light.
yWarning: To prevent ignition of a hazardous atmosphere, do not open the battery
compartment in the hazardous environment. This task must ONLY be performed in an area
known to be non-hazardous.
yWarning: When exchanging batteries, use only ENERGIZER CR123A BATTERIES.
yWarning: To prevent ignition of a hazardous atmosphere, the CR123A batteries must only
be exchanged in an area known to be non-hazardous.
yWarning: To reduce the risk of explosion, do not mix new non-rechargeable batteries
with used non-rechargeable batteries, or mix non-rechargeable batteries from different
manufacturers.
yWarning: Substitution of components may impair intrinsic safety.
STROBE WARNING
Exposure to strobing lights may cause dizziness, disorientation, and nausea. A very small
percentage of people suffer from photosensitive epilepsy and may experience seizures or
blackouts triggered by strobing lights. For more information from the EPILEPSY FOUNDATION
about photosensitivity and seizures, please visit
www.epilepsy.com. Anyone who has had
symptoms linked to this condition should consult a doctor before using this product.
SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY
For personal safety, always con rm the rating of any known hazardous or potentially
hazardous location where the light is to be used.
INSTALLING BATTERIES INTO THE FORTEM
Image 1Image 2Image 3
yTo install the included CR123A Lithium Batteries in the FORTEM, begin by unscrewing the
screw on the battery compartment door. (Image 1)
yInsert both batteries into the battery compartment paying attention to the battery orientation
marked on the back of the battery compartment door. (Image 2)
yRe-install the battery compartment screw by pressing the door fully closed and then
tightening the screw until it is hand tight. CAUTION: Do not cross-tread or strip the screw
threads. (Image 3)
yTest the operation of the light (see OPERATION below).
Product specificaties
| Merk: | NightStick |
| Categorie: | Lamp |
| Model: | XPP-5466 |
Heb je hulp nodig?
Als je hulp nodig hebt met NightStick XPP-5466 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Lamp NightStick
9 Januari 2026
8 Januari 2026
8 Januari 2026
7 Januari 2026
7 Januari 2026
7 Januari 2026
6 Januari 2026
6 Januari 2026
6 Januari 2026
6 Januari 2026
Handleiding Lamp
Nieuwste handleidingen voor Lamp
22 Januari 2026
22 Januari 2026
21 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026
20 Januari 2026