Maxwell MX-25328 Handleiding

Maxwell Multimeter MX-25328

Lees hieronder de 📖 handleiding in het Nederlandse voor Maxwell MX-25328 (26 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 54 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/26
U Mser anUal
Használati Utasítás
ManUal de Utilizare
Užívateľská prírUčka
Product code / Produkt code / Termékkód / Cod produs / Kód produkta:
25328
EN
User Manual
s iafety nforMation
This instrument is designed and tested
according to IEC Publication 1010-1 (61010-1
IEC: 2001), Cat II (1000V), Cat III (600V) and Cat IV
overvoltage standards. Before using this Meter,
read and follow the safety information. To get
the best service from this Meter, read carefully
this users manual and respect the detailed
safety precautions. If the meter or test leads are
damaged, change them immediately.
s Wafety arnings
When using the instrument, the user must
observe all normal safety rules:
- Protect yourself against the danger of electric
shock.
- Protect the instrument against misuse.
- Only use the test probes supplied with the
instrument. Before use, check that they are in
good condition. Never use the instrument if
any of the parts are damaged.
- If the Meter is used near noise generating
equipment, be aware that display may become
unstable, indicate large errors or nothing can
be seen on the instrument’s screen.
- Use the meter only as specied in this manual;
otherwise, the protection provided by the
meter may be impaired. Hereafter, misuse can
cause damage or error.
- Do not use the Meter around explosive gas,
vapour or dust.
- Verify the instrument’s operation by measuring
a known voltage. Do this process before every
usage, because the formerly applied protection
may be impaired.
- When the range of the value to be measured
is unknown, check that the range initially set
on the multimeter is the highest possible or,
wherever possible, choose the auto-ranging/
automatic ranging mode.
- In order to avoid damages to the instrument,
do not exceed the maximum limits of the input
values.
- Caution when working with voltages above
60Vdc or 30Vac rms. Such voltages can cause
electric shock.
- When using the probes, keep your ngers
away from probe contacts and behind the
nger guards.
- Before changing functions, disconnect the test
leads from the circuit under test.
- For all DC functions, including manual or auto-
ranging, to avoid the risk of shock due to
possible improper reading, verify the presence
of any AC voltages by rst using the AC
function. Then select a DC voltage range equal
to or greater than the AC range.
- Before measuring current, turn o power to the
circuit before connecting the Meter to the
circuit.
- Replace the batteries as soon as the low battery
indicator appears.
- Remove test leads from the instrument and
from the circuit as well, before opening the
Meter case.
- If the instrument is not going to be used for a
long time, take out the battery and do not store
the Meter in high temperature or high humidity
environment.
- To avoid damage to the Meter or any injury
always use the standard fuse parameters in case
of any changing: F 500mA/250V, F 10A/600V.
- Never use the instrument if the cover of the
battery case on the backside is open or unt.
User Manual
EN
g feneral eatUres
1. Display
2. REL button
3. RANGE button
4. Hz/Duty button
5. HOLD button
6. RS232 button (PC-link)
7. SELECT button
8. Function selection button
9. "10A" connector
10. "mA" connector
11. "COM" connector
12. "VΩHz " connector
fUnctions
Hold (key)
Short press xes the display on the current value.
A second short press returns the Meter to normal
mode.
Range (key)
This key switches between auto-range mode
and manual mode. If you Press RANGE key for 2
sec, the Meter enters the manual ranging mode.
Auto-range mode turns o.
To exit the manual ranging mode, press and hold
down RANGE key for two seconds. The Meter
returns to the auto-range mode and AUTO is
displayed.
Battery Saver Mode
The instrument enters to "sleep mode"
automatically if the Meter is on but not used
for 30 minutes. Press the " " key or HOLD/LIGHT
rotate the rotary switch to wake the meter up.
REL (key)
To enter and exit relative measurement mode,
press the REL key until you hear “pips that
indicates you that the relative measurement
mode is switched on. The instrument stores
the measured value if you press the key. With
the Meter in the desired function, touch the
test leads to the circuit on which you want
future measurement to be based. After the
measurement you will check the total value on
the screen. Press REL key for more than 2 seconds
to return the Meter to normal operation. This
function cannot work in Frequency Measurement
Mode.
MeasUreMent
Voltage Measurement
To measure AC or DC voltage:
1.: Set rotary switch to the " or " range. V DCmV
2.: Select the " or " range by the " " AC DC SWITCH
key.
3.: Connect the black test lead to the "COM"
terminal and the red test lead to the "VΩHz"
terminal.
4.: Connect the test leads to the circuit being
measured.
5.: Read the displayed value on the screen.
The polarity of red test lead connection will be
indicated when making a DCV measurement.
Warning: To avoid electrical shock and/or
damage to the instrument, do not attempt
to take any voltage measurement that might
exceed 1000V DC or 1000V AC RMS.
1.
2.
7.
9. 12.
10. 11.
8.
3. 4.
5.
6.


Product specificaties

Merk: Maxwell
Categorie: Multimeter
Model: MX-25328

Heb je hulp nodig?

Als je hulp nodig hebt met Maxwell MX-25328 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Maxwell

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter