Maxwell MX-25302 Handleiding

Maxwell Multimeter MX-25302

Bekijk gratis de handleiding van Maxwell MX-25302 (21 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 77 mensen en kreeg gemiddeld 4.0 sterren uit 39 reviews. Heb je een vraag over Maxwell MX-25302 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/21
U Mser anUal
Használati Utasítás
ManUal de Utilizare
Užívateľská prírUčka
DIGITAL MULTIMETER
DIGITÁLIS MULTIMÉTER
MULTIMETRU DIGITAL
DIGITÁLNY MULTIMETER
Product code / Termékkód / Cod produs /Kód produkta:
25302
EN
HU
RO
SK
i
VC9804A+
EN User Manual
G eneral description
Display
3 ½ digit LCD
display with 26mm
characters
Polarity automatic negative
polarity display
Nullication automatic
Measuring method A/D converter
Overload signal only „1/-1” is
displayed
Low battery signal
battery symbol
( ) appears on the
screen
Safety standard
CE EMC/LVD. The
device complies to
the IEC1010 standard
Touch protection
category II double insulation
Operating ambient
temperature
(relative humidity)
0-40 °C (< 80%)
Storage ambient
temperature
(relative humidity)
-20 °C- +60 °C (< 80%)
Battery 1 x 9V IEC 6F22 type
battery
Dimensions 190 mm x 88,5 mm
x27,5 mm
Weight 320g (with battery)
Accessories
user manual,
measuring wires (red
and black, 1 pair)
shock-resistant case
e lectrical
cHaracteristics
Accuracy +/- (% of displayed value + number of
digits) at 23 +/-5 °C, <75%-relative humidity
DC voltage
Range Accuracy Resolution
200 mV
+/- (0,5% + 3)
0,1 mV
2 V 1 mV
20 V 10 mV
200 V 100 mV
1000 V 1 V+/- (1,0% + 10)
Impedance 10MΩ
Overload protection 1000 VDC
200 mV measuring
limit: 250 V DC / AC RMS
2-1000 V measuring
limit: 1000 V DC / AC RMS
AC voltage
Range Accuracy Resolution
2 V
+/- (0.8% + 5)
1 mV
20 V 10 mV
200 V 100 mV
750 V 1 V+/- (1.2% + 10)
Inward impedance
2V measuring limit: 10 MΩ
20-700 V measuring
limit: 10M Ω
Overload protection 1000 V DC /AC RMS
Frequency range
Sine wave and
triangular wave: 40-1000 Hz
Other waveform: 40-200 Hz
Displayed value: average (in case of
True RMS sine signal)
User Manual EN
Resistance
Range Accuracy Resolution
200 Ω +/- (0,8% + 5) 0,1 Ω
2 kΩ
+/- (0,8% + 3)
1 Ω
20 kΩ 10 Ω
200 kΩ 100 Ω
2 MΩ 1 kΩ
20 MΩ +/- (1,0%+ 25) 10 kΩ
200 MΩ +/- (5,0%(rdg-
10)+ 20) 100 kΩ
Outward voltage < 3 V
Overload protection 250V DC/AC RMS
DC current
Range Accuracy Resolution
200 mA +/- (0,8% + 3) 100 μA
20 mA +/- (1,2% + 4) 10 mA
20 A +/- (2,0% + 5) 10 μA
Maximum measuring
voltage 200 mV
Overload protection
0,2 A / 250 V „F” type
fuse and 20 A / 250 V
„F” type fuse
AC current
Range Accuracy Resolution
20 mA +/- (1,0% + 5) 10 μA
200 mA +/- (3,0% + 10) 100 μA
20 A +/- (2,0% + 5) 10 mA
Maximum inward
current
20 A (maximum 10
seconds)
Overload protection
0,2 A / 250 V „F” type
fuse and 20 A / 250 V
„F” type fuse
Frequency range 40-200 Hz
Capacity
Range Accuracy Resolution
20 nF
+/- (2,5% +
20)
1 nF
200 nF 1 nF
2 μF 1 nF
200 μF +/-(5.0%+10) 100 nF
2000 nF +/-(5.0%+10) 100 nF
Measuring frequency 150 Hz
Overload protection 36 V DC / AC RMS
Temperature
Range Accuracy Resolution
-20 °C
1000 °C
+/- (1,0%+3)
< 400 °C 1°C
+/-(1,5%+15)
≥ 400 °C
with a K type temperature sensor
Diode test
Function Description Test state
The opening
voltage is
measured
Opening DC
current appr.
1 mA
Closing DC
voltage appr 3 V
A beeping
sound indicates
if the resistance
between the V/
Ohm and COM
connectors is
less than 90 Ω
Opening
voltage appr.
3 V
Overload protection 250 V DC / AC RMS
Warning: Do not connect external voltage
source to the connectors!
Frequency
Range Accuracy Resolution
2 kHz +/-(3,0%+15) 1 Hz
1 MHz 100 Hz
Inward sensitivity 1 V RMS


Product specificaties

Merk: Maxwell
Categorie: Multimeter
Model: MX-25302

Heb je hulp nodig?

Als je hulp nodig hebt met Maxwell MX-25302 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden