Bekijk gratis de handleiding van Liftmaster LA400UL (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 13 mensen en kreeg gemiddeld 4.6 sterren uit 7 reviews. Heb je een vraag over Liftmaster LA400UL of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Doc 6001309 (01-20289) Page 1 of 2 Rev A
Use the following procedure to remove and replace a LiftMaster Swing Gate Operator cover:
WARNING
Failure to follow the instructions in Step 1 may cause injury due to unexpected gate movement.
Always wait one minute after power-off to service the gate.
1. Turn off power to the gate operator at the circuit breaker and wait for one minute. The gate
will move after one minute if system has the Power Fail Option.
2. When you are certain that the gate will not move due to Power Fail Option operation:
A) Disconnect the Drag Link from the gate Anchor.
B) Loosen the locking nut and mounting bolt, then remove the Swing Arm Cap Assembly and
Drag Link Assembly from the drive shaft. Set this assembly aside.
3. Remove the four cover mounting bolts and remove the gate operator cover.
4. If new cover has optional door: Remove the two top mounting screws from the control box clear
plastic cover. NOTE: These screws must be removed or the control box clear plastic cover cannot
be removed through the gate operator cover door.
5. Install the new gate operator cover and secure with mounting hardware.
6. Reinstall the Drag Link, Swing Arm and Swing Arm Cap Assemblies.
7. Turn on power to the gate operator at the circuit breaker.
Swing Gate Cover Removal and Installation.
SWING GATE OPERATOR COVER
REMOVAL AND INSTALLATION
(WITH OR WITHOUT DOOR)

COPYRIGHT 2001
ALL RIGHTS RESERVED
This document is protected by copyright and may not be copied or adapted without the prior written consent of
LiftMaster. This documentation contains information proprietary to LiftMaster and such information may not be
distributed without the prior written consent of LiftMaster. The software and firmware included in the LiftMaster
product as they relate to this documentation are also protected by copyright and contain information proprietary
to LiftMaster.
FOR TECHNICAL SUPPORT
Call our toll free numbers:
(800) 323-2276
(800) 998-9197
Installation and service information is
available six days a week.
TO ORDER REPAIR PARTS
Call our toll free numbers:
(800) 528-2806
(800) 998-9197
Prepare to provide the following
information when ordering repair parts:
Part Number
Part Name
Model Number
Product specificaties
Merk: | Liftmaster |
Categorie: | Niet gecategoriseerd |
Model: | LA400UL |
Heb je hulp nodig?
Als je hulp nodig hebt met Liftmaster LA400UL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Liftmaster
10 Juni 2025
5 Augustus 2024
8 Juli 2024
8 Juli 2024
11 Juni 2024
11 Juni 2024
11 Juni 2024
9 Juni 2024
9 Juni 2024
27 Mei 2024
Handleiding Niet gecategoriseerd
- Monitor Audio
- Ford
- Miniland
- Keurig
- Valeton
- Fun Generation
- Jysk
- Grundig
- AXESS
- First Alert
- Lanzar
- Mr Steam
- Fisher Paykel
- BOHLT
- DigitSole
Nieuwste handleidingen voor Niet gecategoriseerd
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025