Kyoritsu KEW Mate 2000A Handleiding

Kyoritsu Multimeter KEW Mate 2000A

Bekijk gratis de handleiding van Kyoritsu KEW Mate 2000A (1 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 64 mensen en kreeg gemiddeld 4.9 sterren uit 2 reviews. Heb je een vraag over Kyoritsu KEW Mate 2000A of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
INSTRUCTIONMANUAL
KEW MATE 2000A/2001A
DIGITAL MULTIMETER
WITH
AC/DC CLAMP SENSOR
KYORITSU ELECTRICAL INSTRUMENTS
WORKS, LTD.
1.SAFETY WARNINGS
ThisinstrumenthasbeendesignedandtestedaccordingtoIECPublication61010:
Safety Requirementsfor ElectronicMeasuring Apparatus. This instructionmanual
containswarnings andsafety rules whichmust beobserved bythe userto ensure
safeoperation ofthe instrumentand toretain itinsafe condition. Therefore,read
throughtheseoperatinginstructionsbeforestartingusingtheinstrument.
WARNING
Read throughand understandinstructions containedin thismanualbefore
startingusingtheinstrument.
Saveandkeepthemanualhandytoenablequickreferencewhenevernecessary.
Be sureto usethe instrumentonly inits intendedapplications andto follow
measurementproceduresdescribedinthemanual.
Besuretounderstandandfollowallsafetyinstructionscontainedinthemanual.
Theinstrumentistobeusedonlyinitsintendedapplications.
Understandandfollowallthesafetyinstructionscontainedinthemanual.
Failure tofollow theinstructions maycause injury,instrumentdamage and/or
damage toequipment undertest. Kyoritsuis byno meansliable forany damage
resultingfromtheinstrumentincontradictiontothiscautionarynote.
Failure tofollow theabove instructionsmay causeinjury, damage tothe instrument
and/ordamagetoequipmentundertest.
The symbol indicated on the instrument means that the usermust refer to related
partsofthemanualforsafeoperationof theinstrument.Besureto carefullyreadthe
instructionsfollowingeach symbolinthismanual.
DANGER

isreservedforconditionsandactionsthatarelikelytocauseseriousorfatalinjury.
WARNING
isreservedforconditionsandactionsthatcancauseseriousorfatalinjury.
CAUTION
isreservedforconditionsandactionsthatcancauseminorinjuryorinstrumentdamage.
Following symbols are used on theinstrument and in the instruction manual. Attention
shouldbepaidtoeachsymboltoensureyoursafety.
Refertotheinstructionsinthemanual.
Thissymbolismarkedwheretheusermustrefertotheinstructionmanualsoasnot
tocausepersonalinjuryorinstrumentdamage.
Indicatesaninstrumentwithdoubleorreinforcedinsulation.
Indicatesthatthisinstrumentcanclamponbareconductorswhenmeasuring
avoltagecorrespondingtotheapplicableMeasurementcategory,whichismarked
nexttothissymbol
IndicatesAC(AlternatingCurrent)
IndicatesDC(DirectCurrent).
IndicatesACandDC.
DANGER
Never makemeasurement oncircuits witha maximumvoltage differenceof
600VAC/DC orgreater betweenconductors (300VAC/DCor greaterbetween a
conductorandground).
Donot attemptto makemeasurement inthe presenceof flammablegasses.
Otherwise, theuse ofthe instrumentmay causesparking, whichleads toan
explosion.
Neverattempttousetheinstrumentifitssurfaceoryourhandiswet.
Donotexceedthemaximumallowableinputofmeasuringranges.
Neveropenthebatterycompartmentcoverwhilemakingmeasurement.
Never tryto makemeasurement ifany abnormalconditions, suchas broken
Transformerjawsorcaseisnoted.
Theinstrument isto beused onlyin itsintended applicationsor conditions.
Otherwise, safetyfunctions equippedwiththe instrumentdoesn
t work,and
instrumentdamageorseriouspersonalinjurymaybecaused.
WARNING
Never attemptto make any measurement,if any abnormalconditions are noted,
suchasbrokencase,crackedtestleadsandexposedmetalparts.
DonotturntheFunctionSelectorSwitch whilethetestleadsareconnectedto the
circuitundertest.
Do notinstall substitute parts ormake any modificationto the instrument. Return
theinstrumenttoKyoritsuoryourdistributorforrepairorre-calibration.
Donottrytoreplacethebatteriesifthesurfaceoftheinstrumentiswet.
Always disconnectthe clampsensor andthe testleads from thecircuit undertest
and switchoff the instrument beforeopening the batterycompartment cover for
batteryreplacement.
Stopusingthetestleadiftheouterjacket isdamagedandtheinnermetalorcolor
jacketisexposed.
CAUTION
MakesurethattheFunctionSelectorSwitchissettoanappropriatepositionbefore
makingmeasurement.
Always make sureto place the testleads in thetest lead holder before making
currentmeasurement.
Donotexposetheinstrumenttothedirectsun,extremetemperaturesordewfall.
Besure toset theFunctionSelector Switchtothe "OFF"position afteruse.When
the instrument will not be usedfor a long period of time, place it in storage after
removingthebatteries.
Useadampcloth anddetergentforcleaning theinstrument.Do notuseabrasives
orsolvents.
Keepyourfingersandhandsbehindtheprotectivefingerguardduringmeasurement.
Measurement Category:
Toensure safeoperation ofmeasuring instruments, IEC61010establishes safety
standardsforvariouselectricalenvironments,categorizedasOtoCATIV,andcalled
measurement categories. Higher-numbered categories correspond to electrical
environments withgreater momentary energy,so ameasuring instrument designed
for CAT III environments can endure greater momentary energythan one designed
forCATII.
O :Circuitswhicharenotdirectlyconnectedtothemainspowersupply.
CATII:Electricalcircuits ofequipmentconnected toanACelectrical outlet bya
powercord.
CATIII:Primaryelectricalcircuitsof the equipmentconnected directlytothe
distributionpanel,andfeedersfromthedistributionpaneltooutlets.
CATIV :Thecircuitfromtheservicedroptotheserviceentrance,andtothepower
meterandprimaryover-currentprotectiondevice(distributionpanel).
2.FEATURES
Permits AC/DCcurrent measurement upto 60A using aclamp sensor thatcomes
standardwiththeinstrument
Clampsensorforeaseofuseincrowdedcableareasandothertightplaces
Permitscurrentmeasurementwithanopencurrent-clampsensorthatdoesnotrequire
openingandclosingoperationsbytheuser
Auto-power-savefunction
Buzzerforeasycontinuitychecking
Dataholdfunctiontofreezethereadings
LCDwitha3400countfullscalebargraph
Shockabsorbingholsterforeaseofstorage
Designedto international safety standardIEC61010-1: measurement category
CAT
,300Vandpollutiondegree2.
O: Device which is
not directly
connected to the
mains power supply
3.SPECIFICATIONS
MeasuringRangesandAccuracy(at23
℃±
5
,relativehumidity75%orless)
Electromagnetic
RFfield
1V/m
 compatibility

ACV/DCV/OHMS/FREQUENCYtotalaccuracy=specifiedaccuracy
 (IEC61000-4-3)
ACA/DCA
 totalaccuracy=specifiedaccuracy+5dgt
RF transmitters such as mobile telephones may not be used in close
proximity.
SafetyStandard IEC61010-1
 measurementCAT
,300V,pollutiondegree2
 measurementCAT
,600V,pollutiondegree2
 IEC61010-031
 IEC61010-2-032,IEC61010-2-033
 IEC61326-1(EMC),EN50581(RoHS)
OperatingSystem Dualintegration
DisplayLiquid crystal displaywith maximum reading of 3399as
wellasunitsandannunciators
 Bargraphwithmaximumpointsof33
OverInputIndication "OL"ontheLCD(
Ω
rangesonly)
Auto-rangingOperationShifts tothe nexthigher range whenbar graphincreases
to33points
Shifts tothe next lowerrange when bargraph decreases
to3points
SampleRateNumericreading:about400ms,
 bargraph:about20ms
MODEL
2000A
2001A
Range
60A
100A
ACCurrent
A
DCCurrent
A
ACVoltage
V
Inputimpedance:10M
Ω
DCVoltage
VInputimpedance:10M
Ω
MeasuringRange
0-60.0A
0-100.0A
Accuracy
±
2.0%rdg
±
5dgt(50/60Hz)
±
2.0%rdg
±
5dgt(50/60Hz)
MODEL
2000A
2001A
Range
60A
100A
MeasuringRange
0-
±
60.0A
0-
±
100.0A
Accuracy
±
2.0
rdg
±
5dgt
±
2.0
rdg
±
5dgt
Range
3.4V
34V
340V
600V
MeasuringRange
0-600V
(Auto-ranging)
Accuracy
±
1.5%rdg
±
5dgt(50-400Hz)
Range
340mV
3.4V
34V
340V
600V
MeasuringRange
0-
±
600V
(Auto-ranging)
Accuracy
±
1.5%rdg
±
4dgt
Resistance
Ω/
Range
340
Ω
3.4k
Ω
34k
Ω
340k
Ω
3.4M
Ω
34M
Ω
MeasuringRange
0-33.99M
Ω
(Auto-ranging)
Accuracy
±
1.0%rdg
±
3dgt
Buzzerbeepsbelow30
±
10
Ω
Continuitybuzzerworkson340
Ω
range
only
±
5%rdg
±
5dgt
±
15%rdg
±
5dgt
Frequency
Hz
Range
Current
Voltage
MeasuringRange
0-3.399kHz
3.4kHz-10kHz
(Auto-ranging)
0-3.399kHz
3.4kHz-33.99kHz
34kHz-300kHz
(Auto-ranging)
Accuracy
±
0.1%rdg
±
1dgt
±
0.1%rdg
±
1dgt
Locationforuse Indooruse,Altitudeupto2000m
Accuracy-insured 23
℃±
5
,relativehumidity75%orless
Temperatureand (withoutcondensation)
HumidityRanges
OperatingTemperature 0-40
,relativehumidity85%orless
andHumidityRange (withoutcondensation)
StorageTemperature -20-60
,relativehumidity85%orless
andHumidityRange (withoutcondensation)
Source Two1.5VDCR03(UM-4)batteries
CurrentConsumption Approx.10mA
Power-saveFunctionShifts tothepower-save stateabout 10minutesafter the
lastswitchoperation
 (currentconsumption:approx.10
μ
A)
OverloadProtectionAC/DCcurrentranges:MODEL2000A AC/DC 72A for
10seconds
AC/DCcurrentranges:MODEL2001A AC/DC
120
A for
10seconds
 AC/DCvoltageranges:AC/DC720Vfor10seconds
 Resistanceranges:AC/DC720Vfor10seconds
 Frequencyranges:AC/DC720Vfor10seconds
WithstandVoltageAC3470V for5 sec.between electrical circuitand
housingcase
InsulationResistance 10M
Ω
orgreaterat1000Vbetweenelectricalcircuitand
housingcase
ConductorSize MODEL2000AApprox.
6mmdiametermax.
 MODEL2001AApprox.10mmdiametermax.
Dimensions MODEL2000A128(L)
×
87(W)
×
24(D)mm
 MODEL2001A128(L)
×
92(W)
×
27(D)mm
Weight MODEL2000AApprox.210g
 MODEL2001AApprox.220g
Accessories TwoR03(UM-4)batteries
 InstructionManual
4.INSTRUMENT LAYOUT
Data Hold Button
MODEL2001 MODEL2000
Range Hold Button
Digital Multimeter
Function Selector Switch
Holster
Test Lead
LCD Display
AC/DC Clamp Sensor
BarrierProtective fingerguard
DCA
Zero Adjust
Knob
5.PREPARATIONS FOR MEASUREMENT
1
Checkingbatteryvoltage
SettheFunctionSelectorSwitchtoanypositionotherthantheOFFposition.
Ifthemarksonthe displayisclearlylegiblewithout symbol
"BATT"
showing,battery
voltage isOK. If the displayblanks or
"BATT"
 isindicated, replace the batteries
accordingtosection
8: Battery Replacement
.
NOTE
Whentheinstrumentisleftpoweredon,theauto-power-savefunctionautomatically
shutthepoweroff;ThedisplayblankseveniftheFunctionSelectorSwitchissetto
a position otherthan the OFF position in thisstate.  To power on theinstrument,
turntheFunctionSelectorSwitchorpresstheDataHoldButton.Ifthedisplaystill
blanks,thebatteriesareexhausted.Replacethebatteries.
2
MakesurethattheFunctionSelectorSwitchissettotheappropriaterange.
Also makesure that data holdfunction is notenabled.  Ifinappropriate range is
selected,desiredmeasurementcannotbemade.
3
InstallTestLeadtotheHolsteronthesideofbody
Itis possibleto measurewithseeing theLCD Displaykeep
TestLeadinstallingtotheHolster.
AC/DC
Battery Voltage Warning
Auto Range
Data Hold
Unit
Bar Graph
Buzzer
Manual
Range
Wind the lead around the folder.
Test Leads
AC/DC Clamp Sensor
6.HOW TO MAKE MEASUREMENT
6-1 Current
Measurement
DANGER
Inordertoavoidpossibleshockhazard,nevermakemeasurementoncircuitswitha
maximum voltagedifference of 600VAC/DC orgreater between conductors
(300VAC/DCorgreaterbetweenaconductorandground).
Do notmake measurementwith thetest leadsconnected to thecircuit undertest.
Nevermakemeasurementwiththebatterycompartmentcoverremoved.
Keepyourfingersandhandsbehindthebarrierduringmeasurement.
CAUTION
Whenhandlingtheclampsensor,exercisecautionnottoapplyexcessiveshocksor
vibrationtothesensor.
M
aximum measurableconductor size is MODEL2000A6mm / MODEL2001A
10mmindiameter.
6-1-1DCCurrentMeasurement
(1)TheFunctionSelectorSwithtothe"
A"position.
("DC"and"AUTO"marksareshownonthetopofthedisplay.)
(2)Turnthe0(Zero)ADJknobtosetthereadingofthemultimetertozero.(Ifthiszero
adjustmentismadeincorrectly,measurementerrorswillresult.)
(3)Adjustoneoftheconductorstothecenteroftheclampsensor'sarrow.
( Whenthe position of theconductor is notat the centerof the arrow, theerror
occurs.)
Measuredvalueisshownonthedisplay.
Note:Whencurrentflowsfromtheupsidetotheundersideoftheinstrument,thepolarity
ofthereadingispositive(+).Otherwise,thepolarityofthereadingisnegative(-).
6-1-2ACCurrentMeasurement
(1)SettheFunctionSelectorSwitchto"
A."
("AC"and"AUTO"marksareshownonthetopoftheLCD.)
(2)Adjustoneoftheconductorstothecenteroftheclampsensor'sarrow.
( When the position ofthe conductor is not at the center of thearrow, the error
occurs.)
Measuredvalueisshownonthedisplay.
Note:Unlike DC currentmeasurement, zero adjustment isnot necessary.  There isnot
polarityindicationeither.
6-2 Voltage Measurement
DANGER
Inordertoavoidpossibleshockhazard,nevermakemeasurementoncircuitswitha
maximum voltagedifference of 600VAC/DC orgreater between conductors
(300VAC/DCorgreaterbetweenaconductorandground).
Donotmakemeasurementwiththebatterycompartmentcoverremoved.
Keepyourfingersandhandsbehindtheprotectivefingerguardduringmeasurement.
6-2-1DCVoltageMeasurement
(1)SettheFunctionSelectorSwitchto"
V."
"DC"and"AUTO"marksareshownonthetopoftheLCD.
(2)Connectthe redtest leadto thepositive (+)sideof thecircuit undertest andthe
black testlead to thenegative (-) side. Measured voltage valueis shown onthe
display.
Whentheconnectionisreversed,"-"isshownonthedisplay.
Conductor
MODEL2000A MODEL2001A
Adjust a
conductor to
the center of
the arrow.
Correct Wrong
6-2-2ACVoltageMeasurement
(1)SettheFunctionSelectorSwitchto"
V."
"AC"and"AUTO"marksareshownontheLCD.
(2)Connectthetestleadstothecircuitundertest.
Measuredvoltagevalueisshownonthedisplay.
6-3 Resistance Measurement
DANGER
Nevermakemeasurementoncircuitsthatarelive.
Nevermakemeasurementwiththebatterycompartmentcoverremoved.
Keepyourfingersandhandsbehindtheprotectivefingerguardduringmeasurement.
(1)SettheFunctionSelectorSwitchto"
Ω/
."
(2)Check thatthe displayshows over-range.Short the testleads andcheck thatthe
buzzerbeepsandthedisplayreadszero.
(3)Connect thetest leads to thecircuit under test.Measured resistance valueis
shownonthedisplay. Whenthe measuredvalue isbelowabout 30
Ω
,thebuzzer
beeps.
Note:When the test leads are shorted, the display may read a small resistance value.
Thisistheresistanceofthetestleads.
Ifthereisanopenineitherofthetestleads,"OL"isshownonthedisplay.

Onthe340
Ω
range,"
"isshownontheleftsideoftheLCD.
6-4 Frequency Measurement
DANGER
Inordertoavoidpossibleshockhazard,nevermakemeasurementoncircuitswitha
maximum voltagedifference of 600VAC/DC orgreater between conductors
(300VAC/DCorgreaterbetweenaconductorandground).
Do notmake measurementwith thetest leads connectedto thecircuit undertest.
Nevermakemeasurementwiththebatterycompartmentcoverremoved.
Donotmakecurrentmeasurementwiththetestleadsconnectedtothecircuitunder
test.
Keepyourfingersandhandsbehindtheprotectivefingerguardduringmeasurement.
(1)SettheFunctionSelectorSwitchto"Hz."
(2)Measuringfrequencyofcurrent:
Adjustoneoftheconductorstothecenteroftheclampsensor'sarrow.Measured
valueisshownonthedisplay.
Measuringfrequencyofvoltage:
Connectthetestleadstothecircuitundertest.Measuredfrequencyisshownon
thedisplay.
Note:Measuringrange ofcurrent frequencyis0-10kHz withminimum measurableinput
ofMODEL2000A15A
Typ
/MODEL2001A25A
Typ
.

Measuringrangeofvoltagefrequencyis0-300kHzwithminimummeasurableinput
of30V
Typ
.

Whenmeasuring frequency,donot attachthe clampsensor andthetest leadsto
thecircuitundertestsimultaneously.
Prohibition
7.OTHER FUNCTIONS
7-1Auto-Power-SaveFunction
NOTE
Asmallamount ofcurrentis consumedeven inthe power-savestate. Makesure
tosettheFunctionSelectorSwitchtotheOFFpositionwhentheinstrumentisnot
used.
This functionhelps to avoid unwantedexhaustion of thebatteries because of
leaving theinstrument powered on andextend battery life. The instrument
automatically shiftsto the power-save stateabout 10 minutesafter the last
FunctionSelectorSwitchorotherswitchoperation.
To returnto the normal state: Turn the Function SelectorSwitch or press the
Data Hold Button twice to exitthe power-save state and enable measurement
functions.
7-2DataHoldFunction
This is a function to freeze a measured value on the display.  Press the Data
HoldButtononcetoholdthecurrentreading.Inthisdataholdstate,thereading
isheldevenifinputvaries."H" and"
"marksareshownontheLCD instead
of"AUTO"mark.
Toexitthedataholdstate,presstheDataHoldButtonagain.
7-3RangeHoldFunction
The instrumentdefaults to auto-ranging ("AUTO"is shown onthe LCD).
Pressing theRange HoldButton enables manualselection amongmeasurement
ranges
"
"markisshownontheLCDinsteadof"AUTO"mark
PresstheRangeHoldButtontoselectahigherrange.
To switch from manual range selection to auto-ranging,press down theRange
Hold Button forabout one seconds,or turn the FunctionSelector Switch to
anotherpositionbeforesettingitbacktothecurrentrange.
8.BATTERY REPLACEMENT
WARNING
In order toavoid possible shock hazard,always disconnect the testleads from
thecircuit undertest andsetthe FunctionSelector Switchto theOFFposition
beforetryingtoreplacethebatteries.
CAUTION
Donotmixnewandoldbatteries.
Installbatteries in theorientation as showninside the battery compartment,
observingcorrectpolarity.
Whenthebatteryvoltagewarningmark"BATT"isshownonthetopleftcornerofthe
LCD, replacethe batteries.  Notethat the displayblanks and "BATT"mark is not
shownifthebatteriesarecompletelyexhausted.
(1)SettheFunctionSelectorSwitchto"OFF."
(2)Removetheinstrumentfromtheholster.
(3)Loosen thebattery-compartment-cover-fixing screw onthe lower back ofthe
instrument.
(4)ReplacethebatterieswithtwonewR03(UM-4)1.5Vbatteries.
(5)Putthebatterycompartmentcoverbackinplaceandtightenthescrew.
Screw
Battery
Compartment
Cover
Batteries
92-2318A6-18
DISTRIBUTOR
Kyoritsureserves the rights to change specifications or
designs described in thismanual without notice and without
obligations.
Test LeadCap
Test leadscanbe used under the CAT.II and III environments by
attaching a Protective capas illustrated below. Use of ourProtective cap offers
differentlengthssuitableforthetestenvironments.
Barrer
Protectivefingerguard
It is apartproviding protection against electrical shock and
ensuringtheminimumrequiredairandcreepagedistances.
Protective Cap
Exposed metal part
Uncapped condition for CAT.II environment
Capped condition for CAT.III environments
This instrumentsatisfies the marking requirementdefined in the WEEE
Directive. Thissymbol indicates separate collectionfor electrical and
electronicequipment.
Thismarkingmeanstheyshallbesortedoutandcollectedasordainedin
DIRECTIVE.
This directive is validonly in the EU. Whenyou remove batteries from
thisproductanddisposethem,discardtheminaccordancewithdomestic
lawconcerningdisposal.Takearightactiononwastebatteries,because
thecollectionsystemintheEUonwastebatteriesareregulated.

Beoordeel deze handleiding

4.9/5 (2 Beoordelingen)

Product specificaties

Merk: Kyoritsu
Categorie: Multimeter
Model: KEW Mate 2000A

Heb je hulp nodig?

Als je hulp nodig hebt met Kyoritsu KEW Mate 2000A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden