About This Guide
This document is part of the product.
Do not install or use the device until you have read and understood
this document.
Keep this document for reference throughout the service life of the
device. Pass this document on to any new owner or user.
For the most up-to-date version of this document, go to
www.kathrein-ds.com.
Storage and Transport
Transport and store the device in its original packaging.
Make sure there is no water condensation build-up.
Scope of Delivery
KAZ 10
Pre-assembled equipotential bonding wire
Mounting screws and rawlplugs
Instructions for use
Features
Protection of system components in DVB-S/C/T reception and distri-
bution systems
Deployment of KAZ 10 increases the surge discharge capability of
KAZ11 and KAZ 12
Fulfils categories C2/C3/B2/D1 according to EN 61643-21
Remote feeding for DC voltages from 0...+20 V / max. 0.4 A
Passage for 22 kHz and DiSEqC™ signals
Impedance: 75 Ω
For indoor installation only
KAZ 10 2180000001
Surge Protection Device, 5-way
Installation and Safety Instructions
Danger to life from electric shock and fire hazard due
to electric current!
Connection and installation of the device may only be
carried out by a qualified electrician. National regula-
tions and safety regulations must be complied with
(see also EN 60728-11).
Before installation, the equipment must be checked
for external damage. Should there be damage or
another defect, the equipment must not be installed.
The use of the device is permissible only under the
conditions listed and shown in these installation
instructions. In case of loads which exceed the indi-
cated values, the equipment and any electrical equip-
ment connected to it can be destroyed.
Make sure that the maximum operating voltage of
the system does not exceed the highest continuous
voltage UDC and the maximum remote supply current
IDC.
The device is designed for a clean and dry environ-
ment. Do not expose the device to any mechanical
and/or thermal stress that exceeds the limits of the
specified technical data.
The device must be installed so that it is inaccessible
to children.
The equipment must be provided with an equipoten-
tial bonding wire (Cu, at least 4 mm2).
To increase the protective eect, it is recommended to
use KAZ 11 as a fine protection directly before the device
to be protected as well as KAZ 12 as a coarse protection at
the house entry point (see Fig. 4).
Intended Use
This device is intended solely for installation in DVB-S/C/T reception
and distribution systems. It may only be installed by trained specia-
lists.
Any use other than that specified or failure to observe these applica-
tion notes will invalidate the warranty or guarantee.
The manufacturer accepts no liability for accidents caused by the
user opening the unit.
Opening the unit and attempting to repair it yourself voids all
warranty claims.
Other Measures
With remotely-fed antenna amplifiers, no additional protective circuit
is necessary. With mains-fed devices, an additional protective device
for the mains feed is required (e.g. S-Protector, NSM-Protector or
DEHNsafe). The PE connection of the mains feed must be connected
with the grounding connection of the KAZ 10 surge protector at low
resistance.
If cable systems require the use of a gas discharge arrester at the
building transfer point (BTP), a decoupling distance of at least 1 m
between the BTP and the KAZ 10 is required to ensure coordina-
tion of the two protective measures. The use of an upstream gas
discharge arrester (e.g. KAZ 12) increases the surge current capabi-
lity of the KAZ 10 surge protector.
Equipotential bonding is performed according to Fig. 3. Additio-
nally, the ground terminals must be connected with short cables
(Cu,4mm2).
Connecting the KAZ 10
1. Connect the OUT side of the KAZ 10 to the inputs of the devices to
be protected (multi-switch, amplifier, ...). Use short coaxial cables
with F connectors. Make sure that each system component is
always connected to the equipotential bonding and, if necessary,
insert additional grounding blocks (e.g. EMU 21).
2. The lateral mounting brackets (see 1 Fig. 1) allow you to mount the
surge protector on a flat surface.
3. Connect the cables coming from the satellite antenna (see 2 Fig. 1),
and any existing terrestrial antennas to the IN side of the surge
protector.
4. Connect the housing via the lateral earthing screw (see 3 Fig. 1) to
the local equipotential bonding by the shortest possible route.
IN
OUT
KAZ 10
K-019
218000001
protected
1
2
3
47 - 2400 MHz
DE - 83022 Rosenheim
Fig. 1: Connecting the KAZ 10
Wire Routing
Do not lay protected and unprotected lines directly next
to each other over long distances. Unprotected lines also
include equipotential bonding lines (see Fig. 2).
IN
OUT
KAZ 10
Made in Germany
K-019
218000001
IN
OUT
IN
OUT
KAZ 10
Made in Germany
K-019
218000001
prote cte
IN
OUT
47 - 2400 MHz
47 - 2400 MHz
Fig. 2: Wire routing
Dimensions (mm)
www.kathrein-ds.com | support@kathrein-ds.com 9360000170/b/STM/0120/GB | Subject to change.
Kathrein Digital Systems GmbH | Anton-Kathrein-Straße 1–3 | 83022 Rosenheim | Germany | Phone +49 731 270 909 70
Connection Example
IN
OUT
KAZ 10
Made in Germany
K-019
218000001
p
BTP
47 - 2400 MHz
Fig. 3: Example of equipotential bonding
ZES 11
Potential equalization bar or similar
EMU 24/90
Potential equalization bar
ESD../ESC..
EXR
158
min 4 m
KAZ 12
Coarse protection
KAZ 11
Fine protection
KAZ 10
Medium protection
KAZ 12
21810002
A
IN
OUT
KAZ 10
Made in Germany
K-019
21800000
prote c t e
min 16 mm²
2
T
errestri al
H
hig h
V
hig h
V
low
H
low
1
4
3
6
5
18V
/550mA
KAZ 11
507205
A
EMU 24/90
Fig. 4: Complete house distribution
Technical Data
Type KAZ 10
Order number 2180000001
Transmission range MHz 47–2400
Through loss dB 1.2
Nominal impedance Ω 75
Screening factor dB 5–300 MHz ≥ 85
300–470 MHz ≥ 80
470–950 MHz ≥ 75
950–3000 MHz ≥ 55
Remote feed voltage (max.) UDC +20 V =
Remote feed current 1) (max.) IDC 0.4 A
Temperature range °C -20 to +55
Connection F socket acc. to EN 61169-24
Lightning surge category D1
(10/350 µs)
kA Inner/outer conductor: 0.5
Outer cond./grounding connection: 5
Nominal discharge surge
current (8/20 μs)
kA Inner/outer conductor: 2.5
Outer cond./grounding connection: 10
Protection level at 2 kA / 4 kV
(8/20 μs) Category C2
V ≤ 500
Protection level at 100 A
Category C3
V 120
Response time ns ≤ 1
DC resistance (Input / output
per path)
Ω 3.3
Housing protection class IP 40
Tested categories acc. to EN
61643-21
C2/C3/B2/D1
Packing unit/weight pc./kg 1 (35) / 0.22
1) It must be ensured that both in normal and in faulty operation the remote supply
current does not exceed 400 mA.
Disposal
Electronic equipment
Electronic equipment is not domestic waste – in accord-
ance with directive 2012/19/EC OF THE EUROPEAN PARLIA-
MENT AND THE COUNCIL dated 04th July 2012 concerning
used electrical and electronic appliances, it must be
disposed of properly. At the end of its service life, take this
unit for disposal at a designated public collection point.


Product specificaties

Merk: Kathrein
Categorie: Verlichting
Model: KAZ 10
Kleur van het product: Zilver
Breedte: 145 mm
Diepte: 31.5 mm
Hoogte: 71.5 mm
Impedantie: 75 Ohm
Aansluiting(en): F
Frequentie bereik: 47 - 2400 MHz
Afschermingsklasse: A

Heb je hulp nodig?

Als je hulp nodig hebt met Kathrein KAZ 10 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting Kathrein

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting