Bekijk gratis de handleiding van Kathrein EMK 105 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 26 mensen en kreeg gemiddeld 4.7 sterren uit 13.5 reviews. Heb je een vraag over Kathrein EMK 105 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Montageanleitung der F-Stecker EMK 104/105/106
an den BK-Erdkabeln LCM 33/50/96
www.kathrein-ds.com | support@kathrein-ds.com STM/0121/DE | Änderungen vorbehalten.
KATHREIN Digital Systems GmbH | Anton-Kathrein-Str. 1–3 | 83022 Rosenheim | Deutschland | Telefon +49 731 270 909 70
Schritt 1
Kabel LCM 33/50/96 entsprechend der Vorlage abisolie-
ren. Nach Abschluss des Abisolierens sollte das vorberei-
tete Kabel die folgenden Abmessungen am Kabelende
aufweisen:
EMK 106 mit LCM 96: A = 8,0 mm; B = 11,0 mm
EMK 105 mit LCM 50: A = 10,0mm, B = 12,0mm
EMK 104 mit LCM 33: A = 12,0 mm; B = 16,0 mm
Reinigen Sie ggf. den Kabelinnenleiter und Außenleiter.
Diese müssen fettfrei und ohne Rückstände der Isolie-
rung sein.
Schritt 2
Setzen Sie die Rückmutter über das Kabel und schieben
Sie diese bis zum mechanischen Anschlag zurück.
Schritt 3
Schieben Sie das vordere Ende des Steckers und die
hintere Mutter (mit Kabel) von Hand zusammen. Dabei
rutscht der Innenleiter des Kabels in den mittleren Greif-
mechanismus des Stecker-Vorderteils.
Schritt 4
Ziehen Sie die hintere Mutter mit der Hand so weit wie
möglich an. Ziehen Sie dann mit zwei Maulschlüsseln die
hintere Mutter weiter bis zum mechanischen Anschlag
an. Das Vorderteil des Steckers muss während des Anzie-
hens in seiner Position gehalten werden.

www.kathrein-ds.com | support@kathrein-ds.com 0121/GB | Subject to change.
KATHREIN Digital Systems GmbH | Anton-Kathrein-Str. 1–3 | 83022 Rosenheim | Germany | Phone +49 731 270 909 70
Mounting instructions for the F-plugs EMK 104/105/106
on the BK underground cables LCM 33/50/96
Step 1
Strip the cable LCM 33/50/96 according to the template.
When stripping is complete, the prepared cable should
have the following dimensions at the cable end:
EMK 106 with LCM 96: A = 8.0 mm; B = 11.0 mm
EMK 105 with LCM 50: A = 10.0mm, B = 12.0mm
EMK 104 with LCM 33: A = 12.0 mm; B = 16.0 mm
If necessary, clean the cable inner and outer conductor.
These must be free of grease and without residues of in-
sulation.
Step 2
Place the back nut over the cable and push it back ward
to reach mechanical stop.
Step 3
Push the front end of the connector and the back nut
(with cable) together by hand. During this step, the
cable´s inner conductor slips in to the center seizing me-
chanism of the connector front part.
Step 4
Tighten the back nut by hand as far as possible. Then use
two open ended spanners to further tighten the back nut
to mechanical stop.
The connector body must be kept in place during the ti-
ghtening.
Product specificaties
Merk: | Kathrein |
Categorie: | Niet gecategoriseerd |
Model: | EMK 105 |
Kleur van het product: | Zilver |
Gewicht: | 100 g |
Materiaal behuizing: | Metaal |
Aansluiting 1: | F |
Heb je hulp nodig?
Als je hulp nodig hebt met Kathrein EMK 105 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Kathrein
12 Mei 2025
8 Mei 2025
5 Februari 2025
28 Januari 2025
24 Mei 2024
24 Mei 2024
6 December 2023
13 Juni 2023
8 Juni 2023
23 Mei 2023
Handleiding Niet gecategoriseerd
- Radio Flyer
- LawnMaster
- Sonifex
- Polar
- Active Era
- Ufesa
- Steba
- V-Tone
- Shure
- Seidio
- Twelve South
- Clever Family Homes
- EMOS
- Venicci
- Xoro
Nieuwste handleidingen voor Niet gecategoriseerd
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025