Universal dimmer for rail mounting 50-500 W
Light Management
Universal dimmer for rail mounting 50-500 W
Art. No. : UD1255REG
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Connect all devices and extensions to the same outer conductor. Devices can be
destroyed when connected to different outer conductors.
Fire hazard. For operation with inductive transformers, each transformer must be fused
on the primary side in accordance with the manufacturer's instructions. Only safety
transformers according to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Dimmer
(2) LED on/off: Dimmer on/off
(3) Button n
(4) Button o
3 Function
Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive
transformers or Tronic transformers with halogen lamps
1/6
82557123
J0082557123 06.04.2017
- Suitable for mixed load up to the specified output (see chapter 6.1. Technical data)
- Installation in distribution boxes on DIN rail according to EN 60715
iNo mixed-load of Tronic and inductive transformers.
Product characteristics
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Connection of more than one extension is possible
- Connection for central extensions
- Switch-on via bulb-preserving soft start
- Power extension through power boosters (see power booster instructions)
- Automatic setting of the dimming principle suitable for the load
Load type Electrical behaviour Dimming principle
Incandescent lamps ohmic Phase cut-off
HV halogen lamps ohmic Phase cut-off
Tronic transformers with
halogen lamps
capacitive Phase cut-off
Dimmable inductive
transformers with halogen
lamps
inductive Phase cut-on
iFlickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. These are not device faults.
iBrief flickering upon load detection of ohmic loads. No operation is possible during load
detection.
4 Operation
Operation is performed using the two buttons on the dimmer, 2-wire extension insert (see
chapter 6.3. Accessories) or installation button.
Extensions can be local or central extensions. With a local extension, one dimmer is operated,
while with a central extension several dimmers can be operated simultaneously.
Operation on dimmer or local extension
The functions of the buttons on the dimmer and those of the local 2-wire extension insert are
identical.
Dimmer Extension insert, 2-wire
Button At top of buttonn
Button At bottom of buttono
Buttons and Over entire surface of buttonn o
Switch light
oPress button or button for less than 0.5 seconds.n o
The light is switched on or off using the stored switch-on brightness.
Adjust the brightness
Light is switched on.
oPress the button for longer than 0.5 seconds.n
The light gets brighter up to maximum brightness.
oPress the button for longer than 0.5 seconds.o
Light gets darker to minimum brightness.
2/6
82557123
J0082557123 06.04.2017
Light Management
Universal dimmer for rail mounting 50-500 W
iInstallation button: the light becomes brighter up to maximum brightness, remains there
briefly and becomes dimmer down to minimum brightness, remains there briefly and
becomes brighter again. This process repeats for as long as the push-button remains
pressed.
Switching the light on with minimum brightness
Light is off.
oPress the button for longer than 0.5 seconds.o
Save switch-on brightness
iIn the state as supplied the maximum switch-on brightness is saved.
Light is set to the desired brightness value.
oPress both buttons and for longer than 3 seconds.n o
The switch-on brightness is saved. The dimmer indicates the saving of the brightness by a
softstart of the lighting.
iIt is not possible to save the switch-on brightness via an installation button.
Operation with central extensions
Pressing a central extension always affects all of the connected dimmers. An installation button
as a central extension is not possible.
Switching light on centrally
oPress button at top for less than 0.5 seconds.
The light is switched on using the stored switch-on brightness.
iA light already switched on retains the set brightness.
Switching light off centrally
oPress button at bottom for less than 0.5 seconds.
The light is switched off.
Adjusting brightness centrally
Light is on.
oPress button at top for longer than 0.5 seconds.
The light gets brighter up to maximum brightness.
iLight that is switched off is switched on with minimum brightness and made brighter up to
maximum brightness.
oPress button at bottom for longer than 0.5 seconds.
Light gets darker to minimum brightness.
iLight that is switched off is switched on with minimum brightness.
Switching the light on centrally with minimum brightness
Light is off.
oPress button at bottom for longer than 0.5 seconds.
Saving switch-on brightness centrally
Simultaneous saving of the switch-on brightnesses of all connected, switched-on dimmers.
Dimmers that are switched off are switched on with minimum brightness and made brighter up
to maximum brightness, without saving the switch-on brightness.
Light is set to the desired brightness values.
oPress button over entire surface for longer than 3 seconds.
The switch-on brightnesses are saved. The dimmers indicate the saving of the brightness
by a softstart of the lighting.
3/6
82557123
J0082557123 06.04.2017
Light Management
Universal dimmer for rail mounting 50-500 W


Product specificaties

Merk: Jung
Categorie: Dimmer
Model: UD1255REG

Heb je hulp nodig?

Als je hulp nodig hebt met Jung UD1255REG stel dan hieronder een vraag en andere gebruikers zullen je antwoorden