Light Management
TRONIC dimmer, built-in
Art. No. 247.07 EB
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Dimmer
(2) Connection of control cable for power boosters
(3) Memory switch
(4) Connection of mains and load
3 Function
Intended use
- Switching and dimming incandescent lamps, HV halogen lamps and Tronic- transformers
with halogen lamps
- Suitable for mixed load up to the specified output (see chapter 6.1. Technical data)
- Installation in false ceilings or surface mounting
i No operation with inductive transformers.
Product characteristics
- Operation via installation button with NO contact
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
1/4
82540153
J:0082540153 11.12.2012
- Electronic over-temperature protection
- Can be switched to memory function with brightness memory
- Power extension through power boosters (see power booster instructions)
i Flickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. This does not represent any defect in
the device.
4 Operation
Switch light
o Press push-button briefly.
Memory switch OFF: light is switched on with maximum brightness or light is switched off.
Memory switch ON: Light is switched on with the last brightness set or light is switched off.
Switch light on at minimum brightness
Memory switch OFF.
o Long press on push-button until the light switches on.
Adjust the brightness
Light is switched on.
o Long press on push-button.
Memory switch OFF: the light becomes brighter up to maximum brightness, remains there
briefly and becomes dimmer down to minimum brightness, remains there briefly and
becomes brighter again. This process repeats for as long as the push-button remains
pressed.
i The dimming direction is retained when there is another long press on the push-button.
Memory switched ON: the light becomes brighter or dimmer as far as the first limit value,
remains there briefly, and then changes the dimming direction. This process repeats for as
long as the push-button remains pressed.
i The dimming direction is reversed when there is another long press on the push-button.
i A mains failure of longer than 2 seconds deletes the stored brightness value.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
2/4
82540153
J:0082540153 11.12.2012
Light Management
TRONIC dimmer, built-in
Connecting the dimmer
Figure 2: Connection diagram
(1) Dimmer
(5) Control cable for bower boosters
(6) Load
(7) Installation button, NO contact
(8) Connection of additional installation buttons
i When using power booster, always also load dimmer directly with Tronic transformers or
incandescent lamps.
i Minimum diameter of ceiling opening for installation in false ceilings: 63 mm.
i Illuminated installation buttons may be connected if they have a separate N terminal.
o Connect dimmer and installation button according to connection diagram (figure 2).
o If multiple miniature circuit breakers supply dangerous voltages to the device or load,
couple the miniature circuit breakers or label them with a warning, to ensure release is
guaranteed.
o Reposition memory switch if necessary.
6 Appendix
6.1 Technical data
Rated voltage AC 230 V ~
Mains frequency 50 Hz
Housing temperature 70 °C (tc)
Connected load at 25 °C
i Power specifications including transformer power dissipation.
Incandescent lamps 50 ... 700 W
HV halogen lamps 50 ... 700 W
Tronic transformers 50 ... 700 W
ohmic-capacitive 50 ... 700 W
Connection
single stranded max. 4 mm²
finely stranded with conductor sleeve max. 1.5 mm²
Finely stranded max. 2.5 mm²
Number of control sections
Non-illuminated installation buttons unlimited
3/4
82540153
J:0082540153 11.12.2012