JANDY CD70 Handleiding


Bekijk gratis de handleiding van JANDY CD70 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 5.0 sterren uit 2.5 reviews. Heb je een vraag over JANDY CD70 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Quick Start Guide
Use this template to drill holes for mounting the power pack
Important Safety Information
H0516300 REVC
Corona Discharge
Ozone Generator
CD40 CD70 CD100
WARNING
ELECTRIC SHOCK HAZARD
- Be sure to turn OFF and disconnect from power source before any routine maintenance is performed. Failure to do
so could result in serious injury or death.
- Install at least 5 feet (1.5 meters) from wall of pool using nonmetallic tubing. Install ozone generator no less than
one (1) foot above maximum water level to prevent water from contacting electrical equipment. Install in accordance
with the installation instructions.
- A pressure wire connector is provided on the outside of the unit, marked with “Bonding Lugs” to permit connection
to a minimum No. 6 AWG (13.3 mm
2
) solid bonding conductor between this point and any metal equipment, metal
enclosures of electrical equipment, metal water pipes, or conduit within fi ve (5) feet (1.5m) of the unit or as needed
to comply with local requirements.
- The Jandy
®
Pro Series Ozone generator must be installed in an outdoor location, or indoors in a forced air
ventilated room, and installed so that the orientation is exactly as shown in Figure 1. Install to provide water drainage
of generator to protect electrical components.
- Mount the Jandy Pro Series Ozone generator so that it is inaccessible to anyone in the pool, at least fi ve (5) feet
above ground height, and adequately outside of the direct path of sprinklers. Never attempt any servicing while unit
is wet.
- Plastic ozone supply tubing is supplied with the Jandy Pro Series Ozone generator. Never replace this tubing with
metal tubing.
- A green-colored terminal or a terminal marked G, GR, Ground, Grounding, or the symbol is located inside the
supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the
grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the
circuit conductors supplying this equipment.
WARNING
If the Jandy Pro Series Ozone generator electrical connection is to be attached to the pool controls, be sure the
pool controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the Jandy Pro Series Ozone generator
is connected to an independent electrical supply, then a G.F.C.I. must be installed between the Jandy Pro Series
Ozone generator and the electrical supply. Refer to local codes for complete details.
WARNING
Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can
cause serious harmful physiological effects. DO NOT inhale ozone gas produced by this device.Do not install this
product indoors.
Top Right
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualifi ed in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist, the
maintainer must be a professional with suffi cient experience in pool equipment installation and maintenance so that
all of the instructions in this installation guide AND the complete installation and operation manual accompanying the
product can be followed exactly. Before installing this product, read and follow all warning notices and instructions that
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can
create unwanted electrical hazard which can cause serious injury, property damage, or death. Turn off all circuit breakers
required in order to prevent the possibility of electric shock.
WARNING
Do not store or use gasoline, chemicals or other fl ammable liquids or vapors near this or any other appliance.
Parts & Tools Required
Power Requirements
MODEL
NUMBER
RATED VOLTAGE
RANGE
MAX
CURRENT
POWER
FREQUENCY
CD40 120-240 VAC 0.17A 50-60 Hz
CD70 120-240 VAC 0.29A 50-60 Hz
CD100 120-240 VAC 0.40A 50-60 Hz
Location Requirements
The generator must be mounted (as follows):
In a clean, protected area either indoors or outdoors (preferably
out of direct sunlight) an ideal ambient temperature between
32°F - 120°F (0°C - 50°C). (Indoor installations must be in a
forced air ventilated room.)
Out of reach of sprinklers or drainage spouts.
With suffi cient access for maintenance, all tubing, and
electrical wires.
At least (not less than) one foot above the maximum water level.
So that the bottom of the enclosure is at least three (3) feet
above ground and such that the center of the enclosure is no
more than six (6) feet above ground.
Water Chemistry
Adjust water chemistry to within the following guidelines:
pH: 7.4 - 7.6
Total Alkalinity: 80 - 120 ppm
Free Chlorine: 1.0 - 3.0 ppm
Combined Chlorine (Chloramines): None (superchlorinate
to remove all chloramines)
Chlorine Stabilizer (Cyanuric Acid): 30 - 50 ppm
Calcium Hardess: 200 - 400 ppm
Metals (Iron, Manganese): None
Nitrates: None
Phosphates: None
Top Left
Ozone Generator Mounting Template
Parts:
Ozone Generator
Ozone Tubing
Pipe Cap (3/4)
Flow Meter Assembly
Check Valve
Tube Adapter
Tube Clamps
Injector Manifold Assembly OR
Mixing Degas Vessel (MDV)
Mounting Screws (3), size 0.25
in. (6.3 mm), with anchors
(NOT INCLUDED. Choose
appropriate hardware
for the mounting surface.)
Tools:
Phillips Screwdriver
Scissors to cut tubing
1
4 5
2
3
Mount the Generator
1. Unscrew two (2) screws to open the enclosure door.
2. Locate the three mounting holes in the back of the enclosure.
3. Align the drill guide against the mounting surface using a level. (The drill
guide for aligning the top two holes can be found on the edge of this Quick
Start Guide). Make pencil marks on the mounting surface through the paper
guide holes.
4. Install two (2) screws through the top mounting holes.
5. Install the third screw through the bottom mounting hole.
NOTE: Mounting hardware must be driven until the head fully contacts
the enclosure wall.
Prepare the Pool
Before installation and initial startup of the ozone generator:
1. Backwash or clean fi lters one day before.
2. Superchlorinate the pool water using a chlorine based shock treatment.
3. Test the pool water chemistry according to the guidelines in this
Quick Start Guide.
4. Run the pool fi lter continuously for 24 hours.
Connect to Power Source
IMPORTANT
Be sure to refer to the installation and operation manual and to the IMPORTANT
SAFETY INSTRUCTIONS contained therein, along with those contained on the
reverse side of this guide to avoid possibly serious electrical hazards.
1. Connect the ozone generator to the fi lter
pump relay.
2. Install conduit fi tting through one of the three
knockouts (one on the back, two on sides).
3. Locate the Terminal Block inside enclosure.
(Refer to wiring diagram on the label inside
the enclosure door)
4. For 120V, connect Line to L1, Neutral to
L2 and Ground to the terminal block as
indicated by the label on the inside of the enclosure door.
5. Using a 6 AWG (13.3 mm
2
) conductor, connect the grounding lug on the
bottom of the ozone generator to an appropriate earth contact.
Wiring
Information
Perform Ozone Flow Test
IMPORTANT
If pressure testing a new equipment system, perform the pressure
test prior to connecting the ozone gas line.
Install the 3/4” pipe cap provided onto the manifold injector
before performing the pressure test.
1. Install the tube adapter on the manifold injector. DO NOT
use Tefl on
®
thread tape.
2. Connect the longer ozone tubing (with check valve) onto
the tube adapter.
3. Connect the fl ow meter assembly tubing to the ozone
outlet barb at the bottom of the ozone generator.
4. Connect the ends of the ozone tube and the fl ow meter
assembly.
Ozone
Outlet Barb
Flow Meter Assembly
(Remove after testing)
Ozone Generator System
Ozone Tube
Check Valve
Tube Adapter
Injector Assembly
Heater
Filter
Ozone Generator
Injector
Manifold
Check
Valve
To Pool
Check Valve
(Required if equipment
is above water level)
From Pump
1
2
4
3
5. Hold the fl ow meter assembly tubing so that the clear
plastic chamber is vertical with the longer tubing toward
the bottom.
6. Turn on the pump.
7. Verify that the metal ball in the fl ow
meter assembly fl oats between the
Max and Min lines.
8. If ozone gas fl ow is too low, verify
that other valves in the system are
not inhibiting fl ow through the manifold.
9. Remove the fl ow meter assembly from the ozone outlet
barb and from the ozone tube.
10. Cut off any excess tubing so that the line from the injector
manifold to the ozone generator is straight and free from
dips and loops.
11. Connect the end of the ozone tube to the ozone outlet
barb. Ensure that all hose barb connections are secured
with hose clamps. Secure and route and slack tubing as
necessary, to minimize tripping or entanglement hazard.
Use this template to drill holes for mounting the power pack
Top Right
Top Left
Ozone Generator Mounting Template
Plumb Injector Manifold or Mixing Degas Vessel
IMPORTANT
A check valve must be installed immediately after the heater and before any device
which can introduce strong oxidizers or affect key measurable water parameters. Not
installing a check valve may void the warranty of your heater or heat pump.
The injector manifold is installed in the pool’s main return line after all other pool equipment
(pump, fi lter, heater, and cleaner). Refer to the Owner’s Manual for alternate confi gurations
for systems with the following components: Pool Cleaner, Salt Chlorinator, Chlorine Tab/
Mineral Erosion Feeder, In-Floor Cleaning System, Water Features.
As an alternative to the standard injector manifold confi guration, a mixing degas vessel
(MDV) may be recommended to reduce the chance of fading at the ozone return fi tting in
vinyl lined pools.
To plumb either injector manifold or MDV:
1. Locate an appropriate section of the return line (see below).
2. Observe and follow correct water fl ow direction (indicated by the arrow on the
injector manifold).
3. Connect the injector manifold to existing pipe with PVC cement.
Injector Manifold Plumbing
Heater
Filter
Ozone Generator
Injector
Manifold
Check
Valve
To Pool
Check Valve
(Required if equipment
is above water level)
From Pump
MDV Plumbing
MDV
Cable Tie Mounts
Dedicated Return
Optional
Manual Adjustment Valve
Main Return
Injector
(Flow direction
marked on
injector body)
Heater
Check
Valve
Filter
Flowmeter
(Remove after
verifying flow)
Variable Rate
Check Valve
or Bypass Valve
Check Valve
(Required if
equipment
is above
water level)
Tube/Check Valve Assembly
Destruct Cartridge
Tube
Adapter
Optional
Drain
1/4” ID
Tubing
From Pump
To Pool
To Pool
MIXING DEGAS VESSEL
www.zodiacpoolsystems.com
H0513600_REVA
Check valve, recom-
mended part: Jandy
Pro Series 180 Degree,
2″ - 2 1/2″.
Check Valve (P/N 7305)
Check valve, recom-
mended part: Jandy
Pro Series 180 Degree,
2″ - 2 1/2″.
Check Valve (P/N 7305)
MAX
MIN