Bekijk gratis de handleiding van Intermatic RC6F (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 14 mensen en kreeg gemiddeld 4.9 sterren uit 4 reviews. Heb je een vraag over Intermatic RC6F of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

POOL/SPA CONTROL ACCESSORIES
INSTALLATION
& OPERATING
INSTRUCTIONS
Model: RC6F Air Button
for Through-Hole/Fiberglass Applications
This air button is designed to fit through a 1-5/8 inch
diameter hole in fiberglass, metal or wood materials, up to
3/4 inch thick, where the back of the mounting surface is
accessible during installation. Because of its low profile, it
is the perfect choice for both the vertical and the horizontal
mounting arrangements. It will operate any Intermatic relay
type Air Control up to 150 feet away.
1. Make sure the distance between the Air Control and
Air Button is not over 150 feet.
2. Install PVC conduit between the Air Control and Air
Button, using sweep elbows or forming large radius
curves with heat gun.
3. Drill 1-5/8 inch diameter hole through wall (deck, spa
shell, etc.) at a conveniently accessible location, above
the hightest possible waterline.
4. Insert air button into hole and secure it from the back,
with washer and nut - see illustration.
5. Pull 1/8 inch I.D. vinyl tubing between Air Control and
Air Button, allowing 6 to 10 extra inches at both ends.
Make sure the tubing is especially formulated for such
an application (we recommend using tubing supplied by
), free of kinks, splices and protected fromIntermatic
chemicals and rough edges. Do not allow water or other
contaminants to enter tubing.
6. Firmly press both ends of airhose over the
nipple of the Air Switch and Air Button.
7. Push excess tubing back into conduit. Apply
small amount of silicone sealer around the
flange of Air Button if needed.
The use of permanent glue is not recommended.
1
Instructions
Troubleshooting
SYMPTOM CAUSE(S) CORRECTIVE ACTION
Air Button would not operate 1. Loose air tube connection. Check connections.
equipment. (See also “Useful
2. Water in air tube. Blow out tube.
Information” on back).
3. Air Control is too far from Change Air Button to larger size.
Air Button.
4. Defective Air Button. Change out Air Button.
5. Defective control and/or Check out installation.
equipment.
6. No power to control. Turn breaker ON.
Fiberglass
Wall
Sealing
Washer
Nut
Air Tube
Product specificaties
| Merk: | Intermatic |
| Categorie: | Niet gecategoriseerd |
| Model: | RC6F |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic RC6F stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Intermatic
16 November 2025
13 November 2025
13 November 2025
10 November 2025
8 November 2025
7 November 2025
7 November 2025
6 November 2025
6 November 2025
5 November 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026