Bekijk gratis de handleiding van IFM AY1000 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 29 mensen en kreeg gemiddeld 4.7 sterren uit 3 reviews. Heb je een vraag over IFM AY1000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

You can use this Quick Start for an overview of the AY1000 installation. For complete
installation and configuration information, download the device manual from the ifm.com
website.
Installation and connection
The device must be installed in a suitable housing protected against fire and electrical or
mechanical influences.
Connect the power and Ethernet cables according to the following table
Terminals Description Voltage RangeRemarks
V+, V-
24VDC
PWR IN
Power supply for modules and
sensors (A-ports via PWR Out
connectors)
18…30 V DC,
max. 4 A
Only use PWR connectors on one
side top OR bottom. Do not use
both at the same time.
L+, L-
PWR OUT
Port 1…8
Power supply (A-ports) for
sensors or actuators. Be aware
of the current limitations.
24 V DC,
max. 200 mA
If more current is needed for B-
port devices, take it directly from
the power supply.
Configuration
Configure IP address
You can use the following procedure with the IO-Link master embedded web interface to
configure the AY1000 network settings (administrative rights required).
Note: The AY1000 is shipped from the factory with the Admin account enabled without a
password.
►Open browser and enter IP address of the AY1000.
Note: The AY1000 default IP address is 192.168.1.250. You may need to change your
laptop or PC network address to the same network segment to access the web interface.
►Click on [Configuration] → [NETWORK].
►Click on the button [EDIT].
►Make any necessary network setting changes and click on [SAVE].
Connect and configure devices
►Connect the IO-Link and digital I/O devices
►Use the web interface to configure IO-Link and Profinet-IO settings
–If necessary, confi gure the dedicated digital I/O ports.
–If desired, upload the appropriate IODD files for the IO-Link devices.
Operating instructions
IO-Link Master Profinet AY1000
Product specificaties
| Merk: | IFM |
| Categorie: | Niet gecategoriseerd |
| Model: | AY1000 |
Heb je hulp nodig?
Als je hulp nodig hebt met IFM AY1000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd IFM
15 Juli 2026
14 Juli 2026
13 Juli 2026
12 Juli 2026
12 Juli 2026
12 Juli 2026
9 Juli 2026
9 Juli 2026
9 Juli 2026
9 Juli 2026
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026