IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS AIR
PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked
over by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when
not in use.
4. To disconnect the model HFD-120 series air
purifier, press the Power button to turn the unit
off, grip the plug and pull it from the wall
outlet. Never pull by the cord.
5. Do not use any product with a damaged cord
or plug or if product malfunctions, is dropped
or damaged in any manner. Keep the cord
away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do
not cover with throw rugs. Arrange cord such
that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or use
near water, in a bathroom, laundry area or
other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter ventilation
or exhaust opening as this may cause electric
shock or damage to the air purifier. Do not
block air outlets or intakes.
13. Locate air purifier near the outlet and avoid
using an extension cord.
14. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit
fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
15. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a
distortion of the plug. Contact a qualified
electrician to replace loose or worn outlet.
16. Do not sit, stand or place heavy objects on the
air purifier.
17. Disconnect power supply before servicing.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
OSCILLATING
IFDTOWER
AIR PURIFIER
For Model Series
HFD-120
YOUR AIR PURIFIER
HOW YOUR AIR PURIFIER WORKS
This model air purifier incorporates a 3-stage cleaning
system to help clean the air that passes through the filter
in the unit (Fig. 1).
Stage 1: Washable Pre-Filter
Stage 2: Permanent Washable IFDFilter
Stage 3: Electronic Ionizer
Fig. 1
SET-UP
Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any
wall or furniture.
When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also
help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should
be used underneath to prevent permanent staining. This is especially important in homes with
contamination from smoking or fireplaces.
Control Panel
Permanant
Washable
IFDFilters
(2)
Pre-filter (1)
Rear
Grille
2
OPERATION
Ensure the air purifier is plugged into a working electrical outlet.
Press the power button ( ) once. The unit will start at medium speed for a
few seconds and then automatically change to low speed (Fig. 2).
Press the power button again to select a different cleaning level.
It is recommended you run your air purifier 24 hours a day to ensure
continuous cleaning. Portable air purifiers are more effective in rooms where
all doors and windows are closed.
Fig. 2
ELECTRONIC FILTER CLEAN REMINDER
This model air purifier has an electronic filter check to remind you when to check
and clean the washable IFDfilter based on the air purifier's hours of use.
When the IFD filters need to be cleaned, the light will remain on until it is RESET.
You may unplug the air cleaner without interrupting the filter check.
A red LED light will illuminate when it is time to clean the filter.
You should periodically check the filter. Depending on operating conditions, the
filters should be cleaned at least once a month.
To RESET the Electronic Filter Check:
When the filter monitor light remains on, it is time to check/clean the IFDfilters and reset the filter
monitor, if needed. With the unit powered on, insert the tip of a ball-point pen or paperclip next to the LED
filter check light and hold for approximately 5 seconds until the light turns off (Fig. 3). Depending upon
your individual usage (environment and hours used), you may need to check and clean the filters more or
less frequently. If the IFD
filters are cleaned before the filter monitor light turns on, the filter monitor
should be reset at the same time.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent
upon the concentration of contaminates going through the system. High concentrations of contaminates
such as dust, pet dander and smoking will reduce the useful performance of the filter.
Fig. 3
OSCILLATION FEATURE
To help circulate fresher, cleaner air through the room, this unit has an oscillation
feature.
To turn Oscillation on, simply press the Oscillation button ( ) (Fig. 4).
To turn Oscillation Off, press the button again.
Fig. 4