Winix Zero Max WXAP480 Handleiding
Winix Luchtreiniger Zero Max WXAP480
Bekijk gratis de handleiding van Winix Zero Max WXAP480 (2 pagina’s), behorend tot de categorie Luchtreiniger. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.8 sterren uit 7 reviews. Heb je een vraag over Winix Zero Max WXAP480 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

When to Replace Filters
FilterIndicator LightWhen to ServiceWhen to Replace
Pre-FilternonePermanentClean once every 14 days
Activated Carbon Filternone
Can NOT be WASHED
Every 3 months
True HEPA Filter
Lasts up to
12months
•When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter.
•Intervals between filter replacement may vary depending on environment.
MAINTENANCE
INITIAL OPERATION
REPLACING FILTERS
D4
Resetting Filter Life:
After replacing your True HEPA Filter, place the Pre-Filter back in and close the Front Panel.
While the unit is on, use a small, thin object (such as a paperclip) to hold the Filter Reset
Button for at least 5 seconds until you hear the beep. After the beep, the Filter Replacement
Indicator will disappear. Your Winix True HEPA is now reset.
1.
Remove the front panel by grasping its upper edge
and gently pulling forward.
2.
Remove the Pre-Filter, then the bag of filters behind
it.
3.
Remove filters from protective plastic bag.
4.
Install the filters until they fit securely in place.
03. True HEPA Filter (back)
02. Activated Carbon Filter (middle)
01. Pre-Filter (front)
5.
After filters are installed, close the front panel.
6.
Insert the power cord into an electrical outlet.
WHERE TO USE
MODEL PART DIAGRAM
30~45cm
30~45cm
Allow 30~45cm. of space between TVs, radios, and
other electronics.
Electromagnetic interference from
certain electronics may cause product malfunction.
Place indoors away from direct sunlight.
Direct
exposure may cause product malfunction or failure.
Only place on hard, flat surfaces.
Flimsy or slanted
surfaces may result in abnormal noise and vibrations.
Allow at least 30~45cm. from walls for maximum air
flow
3
True HEPA Filter
2
Activated Carbon Filter
4
PlasmaWave
®
TechnologyPre-Filter
1
4-STAGE AIR PURIFICATION
Air Purification means it
removes inanimate particles
CLEANING CARE
NOTICE
• When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
• Never disassemble, repair, or modify this unit yourself.
• Do not use flammable sprays or liquid detergents.
• Do not allow children to clean or maintain the unit.
• Before cleaning or maintaining, ensure unit is
unplugged.
• Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration
.
SPECIFICATIONS
ModelWXAP480
VoltageAC 220 V - 240 V, 50 / 60 Hz
Power Rate90 W
Verified
Room Size
99 m
2
Dimensions
440 mm (W) x 280 mm (D)
x 600 mm (H)
Weight7.4 kg
Filter SKUFilter D4 : 1712-0100-05
Exterior design, and product specifications may be changed
without prior notice to improve product performance.
AUSCLIMATE FILTER CLUB
For exclusive savings
on replacement filters
AUSTRALIANEW ZEALAND
New Zealand
PO Box 100707
North Shore Mail Centre
Auckland 0745
www.cdbgroup.com
Australia
PO Box 574
South Morang
Victoria 3752
www.cdbgroup.com
FRONT
PACKAGE CONTENTS
BACK
Control Panel
Air Outlet
Vent
Handle
Power Plug
Unit
(1) Pre-Filter
(4) Activated Carbon Filters
(1) True HEPA Filter
User
Manual
Front Panel
01. Smart Sensor
Detects the amount of odorous gas in the
environment. When in Auto mode, the fan speed
adjusts according to the detected amount of gas.
02. Filter Replacement Indicator
LED light indicates when it is time to change
the filter.
03. Filter Reset Button
After replacing the True HEPA Filter, use a small
object such as a paper clip, to press and hold
the Filter Reset Button for at least 5 seconds
until the Filter Replacement Indicator turns off.
04. PlasmaWave
®
Indicator
Indicates whether PlasmaWave
®
is enabled
or disabled.
05. PlasmaWave
®
Button
Enables or disables PlasmaWave
®
. When the
unit is running, you may hear a chirping or
buzzing sound. The sound is from particles
passing through PlasmaWave
®
, it is normal
and does not signify product failure. Press
the PlasmaWave
®
button when the unit is on
to enable or disable this feature.
06. Air Quality Indicator
Color coded LED light indicates one of three
levels of Air Quality: Red (poor), Amber (fair),
and Blue (good).
07. Fan Speeds
Indicates the current fan speed.
08. Auto Mode
Auto Mode automatically adjusts fan speeds
according to your indoor air quality. The fan
speed will adjust to low when air quality is
good, medium when fair, and to high when poor.
09. Sleep Mode
When Sleep Mode is activated, the Air Quality
Indicator LED light is disabled.
•Fan speed will automatically set to minimum
speed (lower than 'Low') which will be nearly
silent.
10. Fan Speed Button
Use the Fan Speed Button to set the desired
Fan Speed. Fan Speeds cycle in this sequence:
Low(1), Medium(2), Turbo(3), Auto
, Sleep,
Low(1).
11. Power Indicator
LED light indicates when the air purifier is
turned on.
12. Power Button
Turns the unit on or off. During the first 30
seconds of powering up, the Air Quality
Indicator will cycle through Blue, Amber and
Red colors.
•Smart Sensor takes approximately 4minutes
to detect the air quality in the environment
before normal operation begins.
13. Light Sensor
When in Auto Mode, the light sensor detects
when to put the unit into Sleep Mode.
•Detects the amount of ambient light in the
environment.
CONTROL PANEL
1210
0204110706
0308
01050913
1
2
3
Latch
03
Latch
02
01
Cleaning the Filters:
Use a vacuum cleaner or soft brush to
clean the Pre-Filter.
•If it is excessively soiled, rinse in room
temperature water. Do not use detergent or
soap.
Allow the filter to dry for 24 hours or
more before using.
Intervals between filter
cleaning may vary depending on the air
quality. Do not use hot water over 40
o
C or
volatile fluids such as paint thinner.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room
temperature water.
•Afterwards, wipe it down with a dry cloth.
Open the front panel and clean the interior
with a vacuum cleaner.
•For optimal performance, clean every
1-2months.
Product specificaties
| Merk: | Winix |
| Categorie: | Luchtreiniger |
| Model: | Zero Max WXAP480 |
Heb je hulp nodig?
Als je hulp nodig hebt met Winix Zero Max WXAP480 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Luchtreiniger Winix
11 April 2026
11 April 2026
10 April 2026
5 December 2025
5 December 2025
16 November 2024
19 Februari 2024
19 Februari 2024
19 Februari 2024
31 Maart 2023
Handleiding Luchtreiniger
Nieuwste handleidingen voor Luchtreiniger
4 April 2026
4 April 2026
2 April 2026
2 April 2026
2 April 2026
1 April 2026
1 April 2026
31 Maart 2026
26 Maart 2026
17 Maart 2026