Honeywell CT87N1001/U1 Handleiding

Honeywell Thermostaat CT87N1001/U1

Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell CT87N1001/U1 (16 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Owner’s Manual
English: Page 1
Mode d’emploi
Français: Page 6
Manual de Uso
EspaĂąol: PĂĄgina 11
T87N Easy-To-SeeTM
The RoundÂŽ
C
O
O
L
•
O
F
F
•
H
E
A
T
F
A
N
O
N
•
•
A
U
T
O
6
7
8
The RoundÂŽ Easy-To-SeeT M
69-1840EFS-07
Check package contents:
• Thermostat
• Wall anchors & screws (2 each)
• Owner's Manual
• Large Print Subbase Switch Labels
• Coverplate
Before you begin, make sure
you have:
• No. 2 Phillips & small pocket
screwdrivers
• Hammer
• Level (optional)
• Pencil
• Drill and bit (3/16” for drywall, 7/32”
for plaster)
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not
place the old control in the trash. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
Pre-installation checklist
This thermostat contains a Lithium battery which may contain Perchlorate material.
Perchlorate Material—special handling may apply,
See www.dtsc.ca.gov/hazardouswaste/perchlorate
Read before installing
T87N, T87N1026
T87N Easy-To-SeeTM • Owner's Manual
69-1840EFS—07 2
System Types
• Gas, oil, or electric heat with air
conditioning
• Warm air, hot water, high-efficiency
furnaces, heat pumps, steam, gravity
• Heat only
• Heat only with fan
• Cool only
System Settings
• Heat, Off, Cool
Fan Settings
• Auto, On
Specifications
Temperature Range
• 40° to 90°F (4.5° to 32°C)
Shipping Temperature
• 20° to 120°F (28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Electrical Ratings
• Voltage: 2030 VAC
• Running current:0.021.0 A,
50/60 Hz
Install the thermostat about 5 feet (1.5 m) above the floor in an
area with good air circulation at average temperature.
Do not install in locations where the thermostat can be affected by:
• Drafts or dead spots behind doors and in corners
• Hot or cold air from ducts
• Sunlight or radiant heat from appliances
• Concealed pipes or chimneys
• Unheated/uncooled areas such as an outside wall behind the
thermostat
NO
NO NO
Installation tips
Product application
This thermostat provides electronic control of 24 VAC single-stage heating
and cooling systems.
English: Français: Español:Page 1 • Page 6 • Página 11
3 69-1840EFS—07
1. Pull wires through wire
hole. Position coverplate
on wall, level and mark hole
positions.
2. Drill holes (3/16” for
drywall, 7/32” for plaster)
and tap in supplied wall
anchors.
3. Pull wire through
coverplate and subbase,
position over anchors,
then insert and tighten
mounting screws. Check
level if desired.
4. Apply the large-print labels
to the coverplate, matching
the labels on the subbase.
1. Loosen screw terminals, insert wires
into terminal block, then re-tighten
screws.
2. Push excess wire back into the wall
opening.
3. Plug the wall opening with
nonflammable insulation to prevent
drafts from affecting thermostat
operation.
Terminal Designations
W Heat relay.
Y Compressor contactor.
G Fan relay.
O Heat pump changeover valve
energized in cooling.
Rc Cooling power. Connect to
secondary side of cooling system
transformer.
R Heating power. Connect to
secondary side of heating system
transformer.
B Heat pump changeover valve
energized in heating.
Wiring
NOTES
R & Rc terminals
In single-transformer system, leave metal
jumper in place between R & Rc. Remove
metal jumper if two-transformer system.
Heat pump systems
If wiring to a heat pump, use a small piece of
wire (not supplied) to connect terminals W
and Y.
Wire specifications
Use 18 to 22-gauge thermostat wire.
Shielded cable is not required.
R
G
W
Y
B
Rc
O
E
F
Coverplate
Subbase
Large-print
subbase switch
labels
Subbase and base installation


Product specificaties

Merk: Honeywell
Categorie: Thermostaat
Model: CT87N1001/U1

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell CT87N1001/U1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Honeywell

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat