Haws 1001HSA Handleiding


Pagina's 22 Niet gecategoriseerd

Bekijk de handleiding van Haws 1001HSA gratis online of download de PDF. Deze handleiding is 1 keer bekeken. Vraag over dit model? Stel een vraag

07/29/2024 Models 1001HSA, 1107HSA, & 1109HSA Page 1 of 22
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail:
[email protected]website: www.hawsco.com
No. 0510002219 (1)
Model 1001HSA, 1107HSA, AND 1109HSA
SINGLE FOUNTAIN ARCHITECTURAL BOTTLE FILLER
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for
a period ofone year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain
specific products or components thereof for an adjusted period. A list of these excepted products and
components and a description of their respective warranty terms may be found here:
www.hawsco.com/warranty. HAWS’ liability under this warranty shall be discharged by furnishing without
charge F.O.B. HAWS factory any goods, or part thereof, which shall appear to the Company upon
inspection to be of defective material or not of first-class workmanship, provided that a claim is made in
writing to Company within a reasonable period after receipt of the product. Where claims for defects are
made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS shall
not be liable for the cost of repairs, alterations or replacements, or the labor required to implement them,
or for any expense connected therewith made by the owner or owner’s agents, except upon written
authority from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor
workmanship, except for replacements, as provided above. Buyer agrees that HAWS has made no other
warranties either express or implied in addition to those above stated, except that of title with respect to
any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special,
incidental, or consequential damages claimed to arise under the contract of sale.
Equipment manufactured by HAWS is warranted to function if installation and maintenance instructions
provided are adhered to. The units also must be used for the purpose for which they were intended. Any
HAWS emergency equipment is intended to supplement first-aid treatment. Due to widely varying
conditions, HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury
or the aggravation of existing or prior injuries.
EXCEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES,
WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE
WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE
EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE,
CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED
TO DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY
DAMAGE, OR OTHER MONETARY LOSS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297
07/29/2024 Models 1001HSA, 1107HSA, & 1109HSA Page 2 of 22
REQUIRED TOOLS (OR EQUIVALENT):
□Adjustable Wrench
□3/8” Socket or Box end Wrench
□9/16” Deep Socket or Box end Wrench
□1/4” bit-holding screwdriver
□T20 bit (supplied)
□Clean cloth or paper towels
□Tubing cutter for polyethylene tubing
□Hacksaw
□Tape Measure
□Bubble level
□Permanent marker
REQUIRED PARTS (NOT SUPPLIED):
□P-trap(s) (1-1/2” recommended) with appropriate seal for 1-1/4” OD tailpieceand waste bend
□Suitable trap adapter(s) (if not already installed – see installation drawing for details)
□Additional waste plumbing as needed (1-1/2” recommended)
□Suitable angle stop valve with 3/8” compression outlet (if not already installed – see installation
drawing for details)
□12X 5/16” fasteners suitable for fastening frame to structural material in wall.
□Plastic cup (for bleeding air out of system following install)
LOCATION OF UNIT: These models are suitable for indoor use only. These units are
unsuitable for corrosive environments (such as enclosed chlorinated pool areas) or very dusty
areas. The ambient air temperature must be maintained between 40°F and 104°F at all times.
Installation into a location not meeting these limitations will void the warranty.
SUPPLY LINE: The min recommended size is 1/2“IPS with 20-105 psig (1.4-7.1 ATM) flowing
pressure. Where sediment or mineral content is a problem, an upstream water pre-filter is
recommended.Do not use with reverse osmosis (RO) water.
PLUMBING CONNECTIONS: Inlet is 3/8” OD polyethylene tubing. A suitable plastic ferrule
and metal insert are provided to allow direct connection to a 3/8” compression water stop
valve. Tailpiece is 1-1/4” OD ABS and waste bend is 1-1/4” OD brass.
ELECTRICAL CONNECTION: 120VAC/60HZ GFCI-Protected circuit, min 15A service.
Dedicated circuit recommended.
SAFETY PRECAUTIONS
CAUTION: Disconnect electrical power to unit before installing or servicing.Note
that some models have more than one connection to the electrical supply.
NOTICE:
A.The electrical connection must have code-approved ground-fault circuit interrupter
(GFCI) protection for personnel.
B.Care should be taken not to damage refrigeration system lines or electrical wires
during installation.
C.Installation must conform to all applicable codes and standards.
D.Maintain 8 inches (20cm) separation from filter circuit board (antenna) at all times.
07/29/2024 Models 1001HSA, 1107HSA, & 1109HSA Page 3 of 22
INSTALLATION PROCEDURE
GENERAL NOTES:
•For all plastic push-in type fitting connections, only connect NSF-61 soft-copper or plastic
tubing. These instructions must be followed to ensure a watertight connection:
a.If tubing needs to be shortened, cut tubing square and clean.
b.Mark from end of tube the depth of insertion (See table below).
c.Push tube into the fitting until it bottoms out.
d.To remove, depress collet and pull tubing out.
Tube OD Size
OD Tolerance
Insertion Depth
3/8”
±.004”
3/4”
•All units ship with both a filter and strainer. The built-in RFID system will determine whether a
filter or strainer is installed and configure the unit accordingly.
A.INSTALLATION STEPS:
1.Verify that the wall cavity, water supply/valve, and drain locations are all in accordance with the installation drawing.
2.Follow the instructions outlined in the installation drawing (pages 12-22) to install the unit.
3.NOTE: The unit is provided with a both a Strainer (110 micron) and a Filter. If desired, install the strainer cartridge instead
of the filter cartridge. Strainer cartridge should be replaced every 5 years.
B.START-UP:
4.Open the water supply valve and check the system for leaks.
5.Reconnect power at the breaker panel, then place a cup under the nozzle of the bottle filler and run the water until the air
has been purged out of the water line.
6.Place a cup over a bubbler (to minimize splattering) and push the front button to activate the bubbler flow. Keep the
button depressed until all air is purged out of the water line.
7.NOTE: If the unit has a filter, run the bubbler for 10 minutes in order to properly flush the filter.
8.If a high/low unit has been installed, place a cup over the high side bubbler and push the front button to activate the
bubbler flow. Keep the button depressed until the air has been purged out of the water line.
9.Remove protective plastic film from the upper and lower stainless-steel panels.
10.The stainless steel panels can be cleaned with stainless steel cleaner and a clean cloth or paper towel. Do not allow the
cleaning fluid to touch the plastic parts of the unit.
C.OPTIONAL PROGRAMMING INSTRUCTIONS:
To enter programming mode, press the Haws logo on the display at the front of the unit (Figure 1) until the up/down arrow
keys and “select” appear on the bottle filler display. Programming mode enters at the top-level menu. In general, the
up/down arrows and select keys work as follows;
Up/Down Arrows – Cycle through the top-level menu items or
values in the programmable fields
Select – enters programming of the associated top-level menu
item, or sets value and advances to next programmable field, or
programs value (indicated by value flashing) prior to returns to the main menu
The following Programming Mode Table can be used as a guide while programming the unit. Settings are retained during
power outages.
Figure 1: Programming Mode Button viewed
from front of unit

Beoordeel deze handleiding


Product specificaties

Merk: Haws
Categorie: Niet gecategoriseerd
Model: 1001HSA

Heb je hulp nodig?

Als je hulp nodig hebt met Haws 1001HSA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden