Gossen Metrawatt METRACLIP 86 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Gossen Metrawatt METRACLIP 86 (51 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/51
METRA CLIP 86
 CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 86 English
CONTENTS
1 PRESENTATION............................................................................................................ 8
1.1 THE SWITCH ....................................................................................................................... 9
1.2 THE KEYS OF THE KEYPAD ........................................................................................ 10
1.3 THE DISPLAY UNIT ........................................................................................................ 11
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 13
1.4 THE TERMINALS ............................................................................................................. 13
2 THE KEYS ..................................................................................................................... 13
2.1 KEY ...................................................................................................................................... 13
2.2 KEY (SECOND FUNCTION) ................................................................................................... 14
2.3 KEY ...................................................................................................................................... 15
2.4 KEY ...................................................................................................................................... 15
2.4.1 In the normal mode ......................................................................................... 15
2.4.2 The MAX/MIN/PEAK mode + activation of the HOLD mode....................... 16
2.4.3 Access to the True- INRUSH mode ( set to ) ...................................17
2.5 KEY ...................................................................................................................................... 17
2.5.1 The Hz function in the normal model ............................................................. 17
2.5.2 The Hz function + activation of the HOLD mode .......................................... 18
2.6 KEY ...................................................................................................................................... 18
3 USE .................................................................................................................................. 19
3.1 COMMISSIONING ........................................................................................................... 19
3.2 STARTING UP THE MULTIMETER CLAMP ............................................................. 20
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 20
3.4 CONFIGURATION ........................................................................................................... 20
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 21
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 21
3.4.3 Programming of the current threshold for the True INRUSH measurement 21
3.4.4 Default configuration ...................................................................................... 22
3.5 .................................................................................. VOLTAGE MEASUREMENT (V) 22
3.6 CONTINUITY TEST ................................................................................................... 23
3.6.1 Automatic compensation of the resistance of the leads ................................. 24
3.7 RESISTANCE MEASUREMENT Ω .............................................................................. 24
3.8 DIODE TEST ............................................................................................................... 25
3.9 CURRENT MEASUREMENT (A) .................................................................................. 25
3.9.1 AC measurement ............................................................................................. 25
3.9.2 DC or AC+DC measurement.......................................................................... 26
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
27
2
English Clamp Multimeter METRACLIP 86
3.11 POWER MEASUREMENTS W, VA, VAR AND PF ..................................................... 27
3.11.1 Measurement of single phase power- .............................................................. 28
3.11.2 Balanced three-phase power measurement.................................................... 28
3.12 “DIRECTION OF ROTATION OF OR OF THE PHASES” “ORDER THE PHASES”
MODE .................................................................................................................................... 29
3.13 FREQUENCY MEASUREMENT (HZ) .......................................................................... 30
3.13.1 Frequency measurement in voltage ................................................................ 30
3.13.2 Frequency measurement in current ................................................................ 31
3.13.3 Measurement of frequency in power .............................................................. 31
3.14 MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE
FREQUENCY OF THE FUNDAMENTAL (NETWORK) ....................................................... 31
3.14.1 Measurement of the THD and of the frequency of the fundamental in voltage
32
3.14.2 Measurement of the THD and of the frequency of the fundamental in current
32
4 CHARACTERISTICS .................................................................................................. 34
4.1 REFERENCE CONDITIONS ........................................................................................... 34
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 34
4.2.1 DC voltage measurement ................................................................................ 34
4.2.2 AC voltage measurement ................................................................................ 35
4.2.3 AC+DC voltage measurement ........................................................................ 36
4.2.4 DC current measurement ................................................................................ 36
4.2.5 AC current measurement ................................................................................ 37
4.2.6 AC+DC intensity measurement ...................................................................... 37
4.2.7 True-Inrush measurement ............................................................................... 38
4.2.8 Continuity measurement ................................................................................. 38
4.2.9 Resistance measurement ................................................................................. 38
4.2.10 Diode test ......................................................................................................... 39
4.2.11 Active DC power measurements ................................ ..................................... 39
4.2.12 Active AC power measurements ..................................................................... 40
4.2.13 Active AC+DC power measurements ............................................................. 41
4.2.14 Measurement of apparent AC power .............................................................. 42
4.2.15 Measurement of apparent AC+DC power ..................................................... 42
4.2.16 Measurement of reactive AC power ............................................................... 43
4.2.17 Measurement of reactive AC+DC power ....................................................... 43
4.2.18 Calculation of the power factor ...................................................................... 44
4.2.19 Frequency measurements................................................................................ 45
4.2.20 Characteristics in THDr ................................................................................. 45
4.2.21 Characterist ics in THDf .................................................................................. 45
4.2.22 Indication of order of the phases .................................................................... 46
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 46
4.4 CHARACTERISTICS OF CONSTRUCTION............................................................... 47
4.5 ............................................................................................................... POWER SUPPLY 47
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 47
3


Product specificaties

Merk: Gossen Metrawatt
Categorie: Multimeter
Model: METRACLIP 86

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt METRACLIP 86 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Gossen Metrawatt

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter