Gossen Metrawatt MetraClip 85 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Gossen Metrawatt MetraClip 85 (42 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/42
METRA CLIP 85
 CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 85 English
CONTENTS
1 PRESENTATION............................................................................................................ 7
1.1 THE SWITCH ....................................................................................................................... 8
1.2 THE KEYS OF THE KEYPAD .......................................................................................... 9
1.3 THE DISPLAY UNIT ........................................................................................................ 10
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 12
1.4 THE TERMINALS ............................................................................................................. 12
2 THE KEYS ..................................................................................................................... 12
2.1 KEY ............................................................................................................................ 13
2.2 KEY ( ) SECOND FUNCTION .......................................................................................... 13
2.3 ............................................................................................................................ KEY 14
2.4 KEY ......................................................................................................................... 14
2.4.1 In the normal mode ......................................................................................... 14
2.4.2 The MAX/MIN mode + activation of the HOLD mode .................................. 15
2.4.3 Access to the True-INRUSH mode ( set to ) ............................... 15
2.5 KEY ............................................................................................................................ 16
2.5.1 The Hz function in the normal model ............................................................. 16
2.5.2 The Hz function + activation of the HOLD mode .......................................... 17
2.6 KEY ......................................................................................................................... 17
3 USE .................................................................................................................................. 18
3.1 COMMISSIONING ........................................................................................................... 18
3.2 STARTING UP THE MULTIMETER CLAMP ............................................................. 18
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 18
3.4 CONFIGURATION ........................................................................................................... 19
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 19
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 19
3.4.3 Programming of the current threshold for the True INRUSH measurement 19
3.4.4 Change of temperature measurement unit ..................................................... 20
3.4.5 Programming of the Adapter function scale factor ....................................... 21
3.4.6 Default configuration ...................................................................................... 21
3.5 .................................................................................. VOLTAGE MEASUREMENT (V) 21
3.6 CONTINUITY TEST ................................................................................................... 22
3.6.1 Automatic compensation of the resistance of the leads ................................. 23
3.7 RESISTANCE MEASUREMENT Ω .............................................................................. 23
3.8 DIODE TEST ............................................................................................................... 24
2
English Clamp Multimeter METRACLIP 85
3.9 CURRENT MEASUREMENT (A) .................................................................................. 24
3.9.1 AC measurement ............................................................................................. 24
3.9.2 DC measurement ............................................................................................. 25
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
26
3.11 FREQUENCY ZMEASUREMENT (H ) .......................................................................... 26
3.11.1 Frequency measurement in voltage ................................................................ 27
3.11.2 Frequency measurement in current ................................................................ 27
3.12 TEMPERATURE MEASUREMENT ............................................................................. 28
3.12.1 Measurement without external sensor ............................................................ 28
3.12.2 Measurement with external sensor ................................................................. 28
3.13 ADAPTER FUNCTION MEASUREMENT .................................................................. 29
4 CHARACTERISTICS .................................................................................................. 30
4.1 REFERENCE CONDITIONS ........................................................................................... 30
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 31
4.2.1 DC voltage measurement ................................................................................ 31
4.2.2 AC voltage measurement ................................................................................ 31
4.2.3 DC current measurement ................................................................................ 32
4.2.4 AC current measurement ................................................................................ 32
4.2.5 True-Inrush measurement ............................................................................... 33
4.2.6 Continuity measurement ................................................................................. 33
4.2.7 Resistance measurement ................................................................................. 33
4.2.8 Diode test ......................................................................................................... 34
4.2.9 Frequency measurements................................................................................ 34
4.2.10 Temperature measurement ............................................................................. 35
4.2.11 Adapter function measurement ....................................................................... 35
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 36
4.4 CHARACTERISTICS OF CONSTRUCTION ............................................................... 37
4.5 ............................................................................................................... POWER SUPPLY 37
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 38
4.7 VARIATIONS THE IN DOMAIN OF USE .................................................................... 38
5 MAINTENANCE .......................................................................................................... 39
5.1 ......................................................................................................................... CLEANING 39
5.2 REPLACEMENT THE BATTERY OF ........................................................................... 39
5.3 METROLOGICAL CHECK ............................................................................................. 40
5.4 REPAIR ............................................................................................................................... 40
6 WARRANTY ................................................................................................................. 40
7 DELIVERY CONDITION ........................................................................................... 41
3


Product specificaties

Merk: Gossen Metrawatt
Categorie: Multimeter
Model: MetraClip 85

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt MetraClip 85 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Gossen Metrawatt

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter