GE ZX6DC49YSS Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor GE ZX6DC49YSS (16 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
GE Monogram®
Installation
Instructions
Professional
Vent Hoods
48" Models
ZV881WSS, ZV891YSS
ZV880WSS, ZV890YSS
36" Models
ZV671WSS, ZV681YSS
ZV670WSS, ZV680YSS
30" Models
ZV370YSS,
ZV371YSS
2
Before you begin—Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector’s use.
IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.
NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer.
NOTE TO CONSUMER: Keep these instructions with your Use and Care Book for
future reference.
This appliance must be properly grounded. See “Electrical Supply”, page 5.
CAUTION
WARNING
If you have questions concerning the installa-
tion of this product, call the GE Answer
Center® Consumer Information Ser vice at
800.626.2000, 24 hours a day, 7 days a week.
If you received a damaged vent hood, you
should contact your dealer.
CAUTION!
Due to the weight and size of these vent hoods
and to reduce the risk of personal injury or
damage to the product, TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
WARNING!
To reduce the risk of fire or electric shock, do
not use this range hood with any external
solid-state speed control device. Any such
alteration from original factory wiring could
result in damage to the unit and/or create an
electrical safety hazard.
To reduce the risk of fire and to properly
exhaust air, be sure to duct air outdoors. Do
not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.
WARNING: TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCTWORK.
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
A. Use this unit only in the manner intended
by the manufacturer. If you have any ques-
tions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock service
panel to prevent power from being switched
on accidentally.
For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
Installation work and electrical wiring must be
done by qualified person(s). In accordance
with all applicable codes and standards
including fire-rated construction.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to
prevent back drafting. Follow the heating
equipment manufacturer’s guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA),
and the American Society for Heating, Refrig-
eration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
Contents Design Information
Models available .................................................................................................................................. 3
Product Dimensions & Clearances .................................................................................................... 4
Advance Planning ............................................................................................................................... 5
Electrical Supply .................................................................................................................................. 5
Installation Preparation
Duct Fittings ....................................................................................................................................... 6
Tools and Materials Required ............................................................................................................ 7
Step 1: Remove the packaging and dis-assemble .............................................................................. 7
Installation
Step 2: Check Installation Hardware ................................................................................................. 8
Step 3: Construct Soffit Framing ....................................................................................................... 8
Step 3A: Construct Wall Mount Framing .......................................................................................... 9
Step 4: Install Hood Below Soffit ..................................................................................................... 10
Step 4A: Install Hood Onto Wall .....................................................................................................11
Step 5: Connect Electrical ................................................................................................................12
Step 6: Connect Ductwork ................................................................................................................12
Step 7: Reassemble Hood.................................................................................................................. 12
Step 8: Install Duct Cover .................................................................................................................13
Step 9: Install Filters ..........................................................................................................................13
3
Design Information
Professional Vent Hoods
Models
Available
These hoods can be installed into a soffit, or
when there is no soffit, they can be installed
directly onto a wall.
48" and 36" wide models are available with
different appearances. Model numbers with
“YSS” have straight sides. Model numbers
ending with “WSS” have sides which taper
inwards from the bottom to the top.
48" Wide Models:
ZV881WSS, ZV880WSS – with tapered sides
ZV891YSS, ZV890YSS – with straight sides
36" Wide Models:
ZV671WSS, ZV670WSS – with tapered sides
ZV681YSS, ZV680YSS – with straight sides
30" Wide Models:
ZV371YSS, ZV370YSS – with straight sides
Before you begin:
Decorative duct covers are available in 6" or
12" heights. The duct covers conceal the
ductwork running from the top of the hood to
the ceiling or soffit. Before you begin, you
should determine the installation height of
the hood and order the correct size duct
cover.
Be sure to order the duct cover which corre-
sponds to your model.
Optional Accessory Duct Covers
Style Hood Model 6" Duct Cover 12" Duct Cover
A-Oval ZV881WSS, ZV880WSS ZX6DC48WSS 6"Hx27-3/8"Wx10-1/4"D ZX12DC48WSS 12"Hx27-3/8"Wx10-1/4"D
A-Oval ZV671WSS, ZV670WSS ZX6DC36WSS 6"Hx22-1/2"Wx9-3/16"D ZX12DC36WSS 12"Hx22-1/2"Wx9-3/16"D
B-Square ZV891YSS, ZV890YSS ZX6DC49YSS 6"Hx47-7/8"Wx12"D ZX12DC49YSS 12"Hx47-7/8"Wx12"D
B-Square ZV681YSS, ZV680YSS ZX6DC38YSS 6"Hx35-7/8"Wx12"D ZX12DC38YSS 12"Hx35-7/8"Wx12"D
B-Square ZV371YSS, ZV370YSS ZX6DC30YSS 6"Hx29-7/8"Wx12"D ZX12DC30YSS 12"Hx29-7/8"Wx12"D
Duct covers for models:
ZV891YSS, ZV890YSS, ZV681YSS, ZV680YSS,
ZV371YSS and ZV370YSS.
Duct covers for models:
ZV881WSS, ZV880WSS, ZV671WSS and
ZV670WSS.
Accessories
(For 48" Wide
Models Only)
Transition duct pieces are available for 48"
wide models. These pieces fit over the outlet
on top of the hood. These transition pieces fit
into a soffit or when there is no soffit, a 12"
duct cover should be used.
Optional 6" or 12"
Duct Cover
Style A-Oval Shape
Optional 6" or 12"
Duct Cover
Style B-Square Shape
ZX48BY, transition to 10" round for horizontal
exhaust.
ZX48AY, transition to 10" round vertical
exhaust.
4-1/2"
10"
18-1/2"
8-3/4"
Duct
Cover
Accessories
8-1/4"
4-3/4" 19-1/4"
C
12"
L
6-5/8"
toC
L


Product specificaties

Merk: GE
Categorie: Niet gecategoriseerd
Model: ZX6DC49YSS

Heb je hulp nodig?

Als je hulp nodig hebt met GE ZX6DC49YSS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd GE

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd