Introduction
The Fluke 80i-110s (the Probe or Product) is a clamp-on AC/DC Current
Probe that reproduces current waveforms found in commercial and industrial
power distribution systems. The Probe performance is optimized for accurate
reproduction of currents at line frequency and up to the 50
th
harmonic
waveform. The 80i-110s is also compatible with any instrument capable of
millivolt measurements.
The Probe provides these benefits:
Accurate AC, DC, and AC+DC current measurements for Electrical,
Electronic, and Automotive applications.
Shielded for high-noise immunity around electronic motor drives and
ignition systems.
Wide measurement range from 50 mA to 100 A, useful to 10 mA.
Jaw shaped for easy access to cramped spaces.
Tactile barrier (see Figure 1, item
).
Safety-designed 600 V insuIated BNC - compatible with Fluke
ScopeMeter
®
test tools, Power Harmonic analyzers, and
oscilloscopes.
Selectable output of 10 millivolts/1 amp for the 100 A range, and
100 mV/1 A for the 10 A range.
Figure 1. 80i-110s AC/DC Current Probe
1
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
Anywhere in the world: +1-425-446-5500
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.
Go to www.fluke.com to register your product and find more information.
Safety
A Warning identifies conditions and procedures that are dangerous to the
user.
Warning
To prevent personal injury and for safe operation of the Product:
Read all safety information before you use the Product.
Carefully read all instructions.
Do not use the Product if it is altered or damaged.
Do not alter the Product and use only as specified, or the
protection supplied by the Product can be compromised.
Comply with local and national safety codes. Use personal
protective equipment (approved rubber gloves, face
protection, and flame-resistant clothes) to prevent shock and
arc blast injury where hazardous live conductors are
exposed.
Hold the Product behind the tactile barrier.
Before each use, examine the Product. Look for cracks or
missing pieces of the clamp housing or output cable
insulation. Also look for loose or weakened components.
Carefully examine the insulation around the jaws.
Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
Use the Clamp only on insulated conductors. Use caution
around bare conductors or bus bars. To prevent electrical
shock, do not touch the conductor.
Symbols
Before You Start
These items are included in the shipment box:
AC/DC Current Probe, 80i-110s
Instructions (this document)
9 volt Battery, type IEC 6LR61
Check the contents of the box for completeness. If something in the box is
damaged or missing, contact your distributor or the nearest sales or service
office.
Symbol Definition
WARNING - RISK OF DANGER.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Consult user documentation.
Double Insulated
Earth
Battery
Application around and removal from uninsulated hazardous live
conductors is permitted.
Conforms to European Union directives.
Conforms to relevant Australian Safety and EMC standards.
Measurement Category III is applicable to test and measuring
circuits connected to the distribution part of the building’s low-
voltage MAINS installation.
This product complies with the WEEE Directive marking
requirements. The affixed label indicates that you must not
discard this electrical/electronic product in domestic household
waste. Product Category: With reference to the equipment types
in the WEEE Directive Annex I, this product is classed as
category 9 "Monitoring and Control Instrumentation" product. Do
not dispose of this product as unsorted municipal waste.


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: 80i-110s
Kleur van het product: Zwart
Gewicht: 330 g
Snoerlengte: 1.6 m
Interface: Banaanstekker
Aantal per verpakking: 1 stuk(s)
Lengte: 231 mm
Temperatuur bij opslag: -30 - 70 °C
Aansluiting(en): BNC
Maximale hoogte, in gebruik: 2000 m
Bedrijfstemperatuur (T-T): 0 - 50 °C
Type product: Stroomtang
Spanningclassificatie: 600 V
Stroom (max.): 100 A
Ondersteunde meetcategorieën: CAT II, CAT III

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke 80i-110s stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023
Fluke

Fluke TiS20+ Handleiding

8 Augustus 2023
Fluke

Fluke i1010 Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd