Bekijk gratis de handleiding van Fischer RSB 10 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 5 mensen en kreeg gemiddeld 4.7 sterren uit 3 reviews. Heb je een vraag over Fischer RSB 10 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

0756
* fischer e GmbH Co. werk KG
0756-CPD-0490
12
ETA 1-12/0258 – ETAG 001-05 Option
FIS SB
RA-SDS
Art. No. 062420
SDS max 1/2“ VK (M16 - M20)
Art. No. 001538
SDS max 3/4“ VK (M20 - M30)
Art. No. 001539
SDS plus 1/2“ VK (M8 - M16)
Art. No. 001537
SK SW 8 1/2“ VK (M8 - M22)
Art. No. 001536
+
fischerwerke GmbH & Co. KG
Weinhalde 14–18
72178 Waldachtal, Germany
Tel. +49 7443 12-0
Fax +49 7443 12-4222
www.fischer.de
123919 · 47/2012 · ZE
+
+
+
+
mm d
o
h
ef
Ø d
b
T
inst, max
1 x
2 x
RSB Art. No.
RG M
M8 Ø 10 mm
80 mm 11
10 1 x RSB 8 518807
M10 Ø 12 mm
75 mm 14
20 1 x RSB 10 mini 518820
90 mm 14
20 1 x RSB 10 518821
150 mm 14
20 2 x RSB 10 mini 518820
M12 Ø 14 mm
75 mm 16
40 1 x RSB 12 mini 518822
110 mm 16
40 1 x RSB 12 518823
150 mm 16
40 2 x RSB 12 mini 518822
M16 Ø 18 mm
95 mm 20
60 1 x RSB 16 mini 518824
125 mm 20
60 1 x RSB 16 518825
190 mm 20
60 2 x RSB 16 mini 518824
M20 Ø 25 mm
170 mm 27
120 1 x RSB 20 518827
210 mm 27
120 1 x RSB 20 E / 24 518828
M24 Ø 28 mm
210 mm 30
150 1 x RSB 20 E / 24 518828
M30 Ø 35 mm 280 mm 40 300 1 x RSB 30 518829
mm d
o
h
ef
Ø d
b
T
inst, max
1 x
RSB Art. No.
RG MI
M8 Ø 14 mm 90 mm 16 10 1 x RSB 10 518821
M10 Ø 18 mm 90 mm 20 20 1 x RSB 12 518823
M12 Ø 20 mm 125 mm 25 40 1 x RSB 16 518825
M16 Ø 24 mm 160 mm 26 80 1 x RSB 16 E 518826
M20 Ø 32 mm 200 mm 40 120 1 x RSB 20 E / 24 518828
RSB
1
1
2
2
3
4b
4a
3b
3a
4 5
5
6
6
7
1
1
2
2 3
3
4
4 5
5
6
6 7
120 h 48 h 30 h 16 h
10 h
45 min 30 min 20 min 5 min 3 min
-19 – -15 -14 – -10 -9 – -5 -4 – ±0 +1 – +5 +6 – +10 +11 – +20 +31 – +40+21 – +30
-30 – -20
RSB
Superbond System
0756
* fischer e GmbH Co. werk KG
0756-CPD-0490
12
ETA 1-12/0258 – ETAG 001-05 Option
FIS SB
*
Information sur le niveau d’émission
de
subst
ances olatiles dans l’air ieur, prv intér
é-
sent
ant un isque de r toxicité par
inhalation,
sur
une échelle de classe allant de A+ (tr
ès
f
aibles émissions) à C (for es t
émissions).
ESR-3572
See ICC-ES
Evaluation Report
at www.icc-es.org
Inspection agency:
IEA (AA-707)
Compressed air pistol
Art. No. 09286
Hand pump
Art. No. 089300

Table III Threaded rod
d Drill bit
d
o
Anchoring depth
h
ef
Minimum member thickenss
h
min
Minimum spacing,
edge distance
s
min
= c
min
Maximum torque
T
inst, max
mm
mm inch mm inch mm inch mm inch
Nm
f
t
– l
b
M8 10 3/8 80 3.15
h
ef
+ 30 h
ef
+ 1.25
40 1.57 10 7.35
M10 12 15/32
75 2.95 45 1.77 20 14.75
90 3.54 45 1.77 20 14.75
150 5.91 45 1.77 20 14.75
M12 14 9/16
75 2.95 55 2.17 40 29.50
110 4.33 55 2.17 40 29.50
150 5.91 55 2.17 40 29.50
M16 18 11/16
95 3.74
h
ef
+ 2d
o
h
ef
+ 2d
o
65 2.56 60 44.25
125 4.92 65 2.56 60 44.25
190 7.48 65 2.56 60 44.25
M20 25 1
170 6.69 85 3.35 120 88.50
210 8.27 85 3.35 120 88.50
M24 28 1 1/8 210 8.27 105 4.13 150 110.60
M30 35 1 3/8 280 11.02 140 5.51 300 221.25
Table II
Rods
mm
Ø
inch
Drill bit
d
o
Anchoring depth
h
ef
Brush
Ø d
b
Capsule
1 x
2 x
RSB Item No.
RG M
M8 3/8 Ø 10 mm 80 mm 11 1 x RSB 8 518807
M10 15/32 Ø 12 mm
75 mm 14 1 x RSB 10 mini 518820
90 mm 14 1 x RSB 10 518821
150 mm 14 2 x RSB 10 mini 518820
M12 9/16 Ø 14 mm
75 mm 16 1 x RSB 12 mini 518822
110 mm 16 1 x RSB 12 518823
150 mm 16 2 x RSB 12 mini 518822
M16 1 1/16 Ø 18 mm
95 mm 20 1 x RSB 16 mini 518824
125 mm 20 1 x RSB 16 518825
190 mm 20 2 x RSB 16 mini 518824
M20 1 Ø 25 mm
170 mm 27 1 x RSB 20 518827
210 mm 27 1 x RSB 20 E / 24 518828
M24 1 1/8 Ø 28 mm 210 mm 30 1 x RSB 20 E / 24 518828
M30 1 3/8 Ø 35 mm 280 mm 40 1 x RSB 30 518829
Installation instruction
see ICC-ES Evaluation Report
No. 3572 at www.icc-es.org
Quality Contr ol Agency IEA (AA -707)
fischer adhesive anchoring system RSB
fischer RSB is an adhesive anchoring system for fastenings in normal weight
concrete.
Important:
Before use, read and review the installation instructions and the SDS (safety data
sheet). Do not use expired adhesive.
A Installation in hammer-drilled hole
1. Drill the hole. Drill hole diameter d
o
and drill hole depth h
o
, see Table 2 3. or
2. Drill hole cleaning: Blow out the drill hole four times with oil-free compressed air
(p ≥ 6 bar). The use of a manual blow-out pump is possible, if at the same time
the drill hole diameter is less than 18 mm and the embedment depth h
ef
is less
than 10d.
3. Resin capsule RSB or two RSB mini, must be pushed into the drill hole by hand.
Depending on the anchor being installed, a suitable setting tool should be used.
4. Only use clean and grease-free anchors. Using a suitable adapter, drive the RG M
into the capsule using a hammer drill set on rotary hammer action. Stop when the
anchor reaches the bottom of the hole and is set to the correct embedment depth.
5. When fully embedded, excess mortar must emerge from the mouth of the drill
hole. If not, the anchor must be pulled out directly and a second resin capsule
must be pushed into the drill hole. Setting process must be repeated, step (4).
6. Wait for the specified curing time. T
cure
see Table 1.
Mounting the fixture T
inst,max
see Table 3.
B Installation in diamond-drilled hole
1. Drill the hole. Drill hole diameter d
o
and drill hole depth h
o
, see Table 2 3. or
Break the drill core and remove.
2. Flush the drill hole until the water becomes clear.
3. Blow out the drill hole two times, using oil-free compressed air (p > 6 bar).
Brush the drill hole two times using a power drill.
Blow out the drill hole two times, using oil-free compressed air (p > 6 bar).
4. Resin capsule RSB or two RSB mini, must be pushed into the drill hole by hand.
Depending on the anchor being installed, use a suitable setting tool.
5. Only use clean and grease-free anchors. Using a suitable adapter, drive the RG M
into the capsule using a hammer drill set on rotary hammer action. Stop when the
anchor reaches the bottom of the hole and is set to the correct embedment depth.
6. When reaching the correct embedment, excess mortar must emerge from the
mouth of the drill hole. If not, the anchor must be pulled out directly and a second
resin capsule must be pushed into the drill hole. Setting process must be
repeated (5).
6. Wait for the specified curing time. t
cure
see Table 1.
Mounting the fixture T
inst,max
see Table 3.
Table I Curing times
Temperature range Curing time
°C °F t
cure
> –20 to –15 > –4 to +5 48 h
> –15 to –10 > +5 to +14 30 h
> –10 to –5 > +14 to +23 16 h
> –5 to ±0 > +23 to +32 10 h
> ±0 to +5 > +32 to +41 45 min
> +5 to +10 > +41 to +50 30 min
> +10 to +20 > +50 to +68 20 min
> +20 to +30 > +68 to +86 5 min
> +30 to +40 > +86 to +104 3 min
+41 – +77 °F
+5 – +25 °C
Store mortar
in a cool dry place.
RA-SDS
Art. No. 062420
+
SDS max 1/2“ VK (M16 - M20)
Art. No. 001538
SDS max 3/4“ VK (M20 - M30)
Art. No. 001539
SDS plus 1/2“ VK (M8 - M16)
Art. No. 001537
SK SW 8 1/2“ VK (M8 - M22)
Art. No. 001536
+
+
+
+
fischerwerke GmbH & Co. KG
Weinhalde 14–18, 72178 Waldachtal, Germany
Tel. +49 7443 12-0, Fax +49 7443 12-4222
www.fischer.de
h
min
T
inst
d
d
0
h
ef
= h
0
s
min
c
min
Brush with extension
Compressed air pistol
Hand pump
A Installation in hammer-drilled hole
1 2
3b
3a
4 5 6
1
2
3
4a
5
6
7
B Installation in diamond-drilled hole
Product specificaties
Merk: | Fischer |
Categorie: | Niet gecategoriseerd |
Model: | RSB 10 |
Heb je hulp nodig?
Als je hulp nodig hebt met Fischer RSB 10 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Fischer
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
24 Mei 2025
24 Mei 2025
Handleiding Niet gecategoriseerd
- Doona
- Teenage Engineering
- DARTS
- Ledger
- WEG
- Positive Grid
- Jedo
- Cre8audio
- Motion
- Safescan
- Grüniq
- Digigram
- Gitzo
- Creamsource
- Dux
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025