FireAngel SP540 Handleiding
Pagina's 32 Rookmelder
Bekijk de handleiding van FireAngel SP540 gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

1
Installation and User Guide
FA4150BW Mains Powered Bluetooth Smoke Alarm
FA4250BW Mains Powered Bluetooth Heat Alarm
FA4452BW Mains Powered Bluetooth Smoke and Heat Alarm
FA4451BW Mains Powered Bluetooth Heat and Carbon Monoxide Alarm
FA4453BW Mains Powered Bluetooth Smoke, Heat and Carbon Monoxide Alarm
TEST YOUR ALARM WEEKLY
®

2
GN6568R4
PLEASE READ THIS GUIDE IN FULL BEFORE USING YOUR ALARM!
230 V AC 50 Hz mains powered alarm. Non replaceable 3 V Panasonic rechargeable lithium
battery backup. CLASS II apparatus. WARNING: Wiring should be installed by a qualied electrician
in accordance with BS7671. We advise you to follow the new harmonized cable colour coding as
specied in BS7671.
WARNING: Experience has shown that children may not be woken by re alarm tones. It is
important that children are never left alone in a house. Families should have a re escape plan that
is rehearsed, so that everyone knows how to escape when re occurs. The immediate priority when
re occurs is to ensure that any sleeping children are woken from sleep and are immediately taken
to a place of safety outside the property, along with all other occupants. The re and rescue service
should always be called without delay, no matter how small the re.
This user guide is also available in large text and other formats.
Please call 0330 094 5830 for further information.
FA4453BW Smoke, Heat & CO Alarm
FA4250BW Heat Alarm
FA4451BW Heat & CO AlarmFA4452BW Smoke & Heat Alarm
FA4150BW Smoke Alarm
Performance Tested
BS 5446-2: 2003
26
Performance Tested
EN14604:2005+AC:2008
2531
EN14604:2005 +AC:2008
Smoke alarm devices
FSTDOP26001
26
Performance Tested
EN14604:2005+AC:2008
BS 5446-2: 2003
2531
EN14604:2005 +AC:2008
Smoke alarm devices
FSTDOP26002
26
Performance Tested
BS 5446-2: 2003
EN 50291-1:2008
26
Performance Tested
EN14604:2005+AC:2008
BS 5446-2: 2003
EN 50291-1:2008
2531
EN14604:2005 +AC:2008
Smoke alarm devices
FSTDOP26003
26

3
Introduction. . . . . . . . . . . . . . . . . . . 5
System Grades and Categories . . . . . . . . 7
Positioning . . . . . . . . . . . . . . . . . . . 8
Hardwire Installation. . . . . . . . . . . . . .11
Anti-Tamper. . . . . . . . . . . . . . . . . . .13
Hardwire Interconnect . . . . . . . . . . . . .13
Bluetooth Wireless Interlink . . . . . . . . . .14
Interlinking with the mobile app. . . . . . . .15
Interlinking manually . . . . . . . . . . . . . .15
Mixed Systems. . . . . . . . . . . . . . . . .16
INSTALLER GUIDE
Alarm Test. . . . . . . . . . . . . . . . . . . .17
Alarm Smart Silence
TM
. . . . . . . . . . . . .18
Low Battery Warning. . . . . . . . . . . . . .19
Sleep Easy
TM
. . . . . . . . . . . . . . . . . . .19
Fault Indication. . . . . . . . . . . . . . . . .19
End of Life. . . . . . . . . . . . . . . . . . . .19
Nighttime Sensing . . . . . . . . . . . . . . .19
Alarm Memory . . . . . . . . . . . . . . . . 20
Fire Safety. . . . . . . . . . . . . . . . . . . 21
CO Awareness. . . . . . . . . . . . . . . . . 22
Product Indicators . . . . . . . . . . . . . . 24
Maintenance. . . . . . . . . . . . . . . . . . 26
Disposal. . . . . . . . . . . . . . . . . . . . 26
Technical Specications . . . . . . . . . . . 27
Warranty. . . . . . . . . . . . . . . . . . . . 28
USER GUIDE
FireAngel Safety Technology, Ground Floor, BOURN, 1 Manor House Drive, Coventry, CV1 2TA, UK
Email: customersupport@fireangeltech.com / Web: fireangel.co.uk
Technical Support Line: 0330 094 5830
Product specificaties
| Merk: | FireAngel |
| Categorie: | Rookmelder |
| Model: | SP540 |