Bekijk gratis de handleiding van Extron IPA T RLY4 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 49 mensen en kreeg gemiddeld 4.8 sterren uit 5 reviews. Heb je een vraag over Extron IPA T RLY4 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

1
IMPORTANT:
I
I
I
IM
M
M
MP
P
P
PO
O
O
ORT
RT
RT
RTA
A
A
AN
N
N
NT:
T:
T:
T:
Go to www.extron.com for the
complete product specifications.
IPA T RLY4 • Setup Guide
This guide provides instructions for an experienced installer to install the Extron IPA T RLY4 relay accessory and to make all
connections.
The IPA T RLY4 is an IPLink® Accessory product. The relay accessory consists of four output relays with normally open (when the
relay is de-energized) (NO) and normally closed (NC) contacts.
The relay accessory converts a solid state (up to 12 VDC) signal, from a Flex I/O port or Digital I/O port on an Extron control
processor, to a relay contact closure. The relay contacts can handle up to 24 VAC or 24 VDC as a tally signal, contact closure
signal, or control signal to drive devices in your system, such as a lighting system (see gure 1) or remote screens. The relay
contacts are protected by an overvoltage circuit.
The compact IPA T RLY4 can be concealed out of the way anywhere in your system with the included hook and loop fastener strip.
IPA T RLY4
1 2 3 4 C
INPUT S
PWR OUT = 6W
V C G
VOL
POWER
12V
1.0A MAX
G
T xRx
RT SCT S
COM 1
3
1 24 G
DI GIT AL I/O
G
T xR x
COM 2
-S+V +SG
eB US
C1 2
RE L AY S
SG
IR /S
LAN
AV
LAN
Extron
IPCP Pro 255Q xi
Ethernet Control
Processor
Extron
IPA T RLY4
Relay Accessory
NO C NCNO C NCNO C NCNO C NC
RELAY 1RELAY 2RELAY 3RELAY 4
Lighting System
Front
Rear
Extron
12 V Power
Supply
+12 VDC
(Common)
Figure 1. Typical IPA T RLY 4 Application
Connections
NOTE:The 5-pole captive screw input connector and four 3-pole captive screw output connectors are included with the
unit, but you must supply the cable. Extron recommends the CTL Series cable, available non-plenum and plenum bulk
rolls and plenum pre-cut lengths.
IPA T RLY41 2 3 4 C
INPUTS
NO C NCNO C NCNO C NCNO C NC
RELAY 1RELAY 2RELAY 3RELAY 4
AA
BBBB BBBB
Figure 2. IPA T RLY4 Connections
Input Connections
A — Connect the 12 VDC source to the common voltage (C) terminal of the 5-pole captive screw Inputs
connector. Connect the appropriate terminal (1 though 4) to the digital output or flex I/O of the Extron control
processor.
Product specificaties
| Merk: | Extron |
| Categorie: | Niet gecategoriseerd |
| Model: | IPA T RLY4 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extron IPA T RLY4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Extron
4 Maart 2026
11 December 2025
9 December 2025
9 December 2025
9 December 2025
29 November 2025
29 November 2025
23 November 2025
7 November 2025
5 November 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026