Extron ACP VC1 D Handleiding


Bekijk gratis de handleiding van Extron ACP VC1 D (8 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 36 mensen en kreeg gemiddeld 4.4 sterren uit 18.5 reviews. Heb je een vraag over Extron ACP VC1 D of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/8
1
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
ACP VC1 D • Setup Guide
The Extron ACP VC1 D Audio Control Panel is a fully congurable control interface for use with any Extron ACP-enabled device.
Each ACP VC1 D includes two ACP ports, which support power and communication between the host device and the
ACP VC1 D. Up to eight ACP panels can be used per host device for more demanding control needs.
Planning System Installation
When planning an ACP system installation, consider how many ACP panels to use, maximum cable distance, and mounting (see
the ACP VC1 D product page at www.extron.com for more information regarding the ACP VC1 D).
MUTE
VOLUME
MUTE
VO
L
U
ME
+V
ACP
PWR LOAD = 1.5W
+S -S G
+V +S -S G
STATUS
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
AA
B
B
C
C
DD
EE
F
F
Figure 1. ACP VC1 D
A
Front Panel Rotary Volume Knob
D
Connection Status LED
B
Front Panel Mute Button
E
Reset Button
C
ACP Ports (2)
F
Bus ID DIP Switches
Installation
Step 1: Get Ready
Use the following checklist to prepare for installation:
Download and install the latest software, rmware, and device drivers needed to congure the host device and the
connected ACP devices (see the host device user guide, available at www.extron.com, for details regarding software and
drivers).
Obtain cables, mounting hardware, and any other supplies required for the installation.
2
ACP VC1 D • Setup Guide (Continued)
Step 2: Prepare the Installation Site
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
Extron recommends installing the ACP VC1 D into a grounded, UL Listed electrical junction box.
Extron recommande d’installer l’ACP VC1 D dans une boîte de dérivation électrique mise à la terre, certiée UL.
If the ACP VC1 D will be installed into ne furniture, it is best to hire a licensed, bonded craftsperson to cut the access
hole and perform the physical installation so the surface will not be damaged.
S’il est prévu d’installer l’ACP VC1 D dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et
qualié pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
NOTE: For the installation to meet UL requirements and comply with National Electrical Code (NEC), the ACP VC1 D must
be installed in a UL Listed junction box. The end user or installer must furnish the junction box. It is not included with the
ACPVC1 D.
Americans with Disabilities Act (ADA) Compliance
When planning where to install these devices, consider factors affecting accessibility of the button panel such as height from
the oor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see sections 307
(“Protruding Objects”) and 308 (“Reach Ranges”) of the 2010 ADA Standards for Accessible Design available at
http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf.
Site Preparation
Extron offers an assortment of mud rings, optional ULListed in-wall junction boxes, external wall boxes (EWBs), and surface or
tabletop mounting boxes for use with the ACP button panels. The ACP VC1 D is a US 1-gang size device.
Step 3: Removing the Plastic Faceplate, Removing the Button Panel, and Changing the Button
The plastic faceplate and button can be replaced. Additional
buttons ship with the device and others can be ordered from
www.extron.com.
To change the button:
1. Remove the two screws holding the plastic faceplate to the
metal mounting plate and separate the faceplate from the
button plate (see
1
in the figure to the right).
2. Insert a small flat-bladed screw driver into the notch at the top
of the button plate. Release the catch holding the button plate
to the metal mounting plate (
2
).
3. Repeat step 2 to release the catch at the bottom of the plate.
4. Tilt the top of the button plate forward as it is removed to
prevent the button from falling out.
ACP VC1 D
Faceplate
MUTE
VOLUME
1
2


Product specificaties

Merk: Extron
Categorie: Niet gecategoriseerd
Model: ACP VC1 D

Heb je hulp nodig?

Als je hulp nodig hebt met Extron ACP VC1 D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Extron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd