Extech PD20 Handleiding
Pagina's 1 Meetapparatuur
Bekijk de handleiding van Extech PD20 gratis online of download de PDF. 23 mensen vonden deze handleiding nuttig. Vraag over dit model? Stel een vraag

PD20‐en‐US_V1.09/14
1
2
5
6
3
4
ModelPD20‐Thermo‐Pedometer
Safety
KeepthePD20andthebatteryoutofreachofchildren
Don’texposePD20toliquid,fire,shockorvibration
Pleasereplacethebatteryassoonasitlosespower
Wearprotectivegearwhenhandlingleakingbatteries
Description
1.Display
2.RECbutton
3.ON‐OFFbutton
4.Eyeletforlanyard
5.MODE
button
6.Set°C/°Fbutton
BatterydoorandResetButton
LocatedonofbackPD20
BasicOperation
Peeltheprotectivefoiloffofthedisplay.
Openthebatterycompartment(usingacoin),removethe
insulationstrip,andclosethebatterydoor.ThePD20will
powerON.replaceIfnot,thebattery.
‘0STEP’willshowatthetopofthedisplayandthetime
will
showatthebottomwhentheunitisON.
Press‐andholdtheONOFFbuttontoswitchOFF.Pressand
holdtheONON‐OFFbuttontoswitchagain.
The‐PD20enterspowersavermodeafter10minutesof
inactivity(onlythetimeappearsonthedisplay).
To
deactivatepower‐savermode:movetheinstrument
slightly;theSTEPdisplaywillappear.
SettingsMode
1.PressandholdtheSET°C/°Fbuttonfor3seconds.
2.°C°ForwithMODEAM/PMwillflash.Press
tochange
units.PressSET°C/°Fagaintoconfirm.
3.theThetimewillappearwithhourdigitflashing.PressREC
orMODE
toincrease/decreasethethehour.PressSET
°C/°Fbuttontoconfirm.
4.Minuteswillbeginflashing.PressREC
orMODE
to
increase/decreasetheminutesthenpressSET°C/°F.
5.LCDThesteplengthwillappearonthe(default60cm/
23.5in).PressREC
orMODE
toincrease/decreasethe
steplength(1cm).PressSET°C/°Ftoconfirm.
6.theTheweight(default110lbs./50kg)willappearonLCD.
PressREC
orMODE
toincrease/decreasetheweight
(1lb.).PresstheSET°C/°Fbuttontoconfirm.
STANDARDStepCounting
PressandholdMODEfor3secondstotoresetthedisplay‘0
STEP’.Note:nonThePD20ignores‐walkingmotion.Stepswill
beseveralregisteredontheafterdisplayregularstepsare
detected.
TemperatureIndication
PressandreleaseSETthe°C/°Fbuttontodisplaytheactual
temperatureforfiveseconds.
DisplayModes
Usemode:thetheMODEbuttontoselectdisplay
Calorieconsumption/fatburn:KCALandBGMorOZ
Distancecoveredinkilometers(KM)ormiles(M)andthe
timetaken(inhours/minutesatbottomofdisplay)
Averagespeedkilometersormilesperhour
PressMODEtotoreturnnormalmode(STEP
andtime).
STANDARD7‐DayStorage
PressRECand‘DAYSAGO:1’thewillappearondisplay.Use
RECtoselectthethedesiredday(DAYSAGO‐17).Once
desireddayisreached,pressMODEtoselect:
Calorieconsumption/fatburn:KCALandBGMorOZ
DistancecoveredinKMormiles(M)andthetimetaken(in
hoursandminutesshownatbottomofdisplay)
AveragespeedinKM/HorM/H
Note:memoryTheday’sdataisstoredinaftermidnight.The
currenttimeand‘0STEP’appearonthethedisplay;selected
settingsareretained(seeSettingsMode).
CONTINUOUSStepCounting
ThePD20recordstheno.ofstepswalkedcontinuously
withoutrestinglongerthan5minutes.Stopping>5minutes
startsanewsession(countingfromzeroagain).Onlythe
largeststepsessionofthedayandwillbeshownstored.See
instructionsbelow:
1.HoldREC
fordisplays)3seconds(‘CONTSTEP’
2.7)PressREC▲toshow‐7day‐CS‐storage(DAYSAGO‐1
3.thetheWhenonappropriatedaypressMODE▼tocycle
followingdisplays:
Calorieconsumptionandfatburned(KCALandGMor
OZ).
Distanceandtime(KMorMandthetimeinhoursand
minutes).
Averagespeed(KM/HorM/H)
4.thedataAftermidnight,currentwillbestored
TOTAL‐7DayStepStorage
TheTotalStepStoragerecordstotalofno.stepswalked.This
featureregularcomesafterthe‐7daywhen‐storagefeature
steppingthroughthefeatures.
‘A’appearsonrightsideofthedisplayinthismode.
Whenthetotalaccumulatedstepsexceeds5digits
(>99999steps),theleastsignificant
digitdisplaysonthe
secondline.
The‐‐basicoperationisthesameasthestandard7day
storagepreviousfeatureexplainedinthesection.
PressandholdMODE▼toclearthestorageandrestart
countingfromzero.
Note:ContinuousStepisanimportantindicatorshowingthe
intensityof
awalkingexercise.Doctorspreferthisnumber
overthetotalstepswalkedperday.
RESETButton(rear)
Toreturntheunittoitsfactorydefaultstate,useapaperclip
orpintopresstherearRESETbutton.
AttachingthePD20
Belt:AttachthePD20withthepouchcliponawaistbandorbelt.
Aroundtheneck:ThreadalanyardthroughthePD20eyeletand
makeasecureknot.
Maintenance
CleansoftDothePD20withadampcloth.notusesolventsor
abrasives.Ifthetheunitdoesnotworkproperly,pleasereset
instrumentorreplacetheCR2032battery(rear).
Specifications
Max.Numberofsteps‐099,999
Max.Distance0‐624.99mi(0‐999.99km)
Max.Speed0‐6.25mi/h(0‐10km/h)
Max.Calorieconsumption0‐99,999kcal
Max.Fatburned0‐35.9oz.(0‐999.9g)
OperatingTemperature14°F122°F‐‐(10°C50°C)‐
Stepcountaccuracy±50per1000steps
Batterypower
1xCR2032buttoncell
Dimensions2.200.633.1580xxin(56x16xmm)
Weight1.20oz.(34g)[instrumentonly]
Copyright©2014FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorininpartanyform
www.extech.com
Product specificaties
| Merk: | Extech |
| Categorie: | Meetapparatuur |
| Model: | PD20 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extech PD20 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Extech
Extech RF11 Handleiding Extech RH550-P Handleiding Extech RF30 Handleiding Extech DV23 Handleiding Extech IR260 Handleiding Extech RD300 Handleiding Extech DL150 Handleiding Extech 407790 Handleiding
Alle Extech Meetapparatuur handleidingen
Populair in Meetapparatuur
Handleiding Meetapparatuur
Nieuwste handleidingen voor Meetapparatuur
PCE Instruments PCE-RD 100 Handleiding Leica Lino L6Gs Handleiding X-Sense XR0B-SR Handleiding X-Sense XR0A-SR Handleiding PCE Instruments PCE-RVP 120 Handleiding PCE Instruments PCE-XXM 40 Handleiding PCE Instruments PCE-RCM 03 Handleiding Yato YT-2865 Handleiding PCE Instruments PCE-PME 10 Handleiding PCE Instruments PCE-PME 125 Handleiding