Bekijk gratis de handleiding van EXSYS EX-60327 (2 pagina’s), behorend tot de categorie Csavaros gép. Deze gids werd als nuttig beoordeeld door 52 mensen en kreeg gemiddeld 4.7 sterren uit 4 reviews. Heb je een vraag over EXSYS EX-60327 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
To clean the unit, use only a dry, lintfree cloth and apply light pressure to remove dirt. Take -
care not to leave any fibres of the cloth in the connectors.
Never use a damp or wet cloth for cleaning!
CLEANING
Terminal Block:
V+V- V+V-
ATTENTION!
Power supply OUTPUT, NO connection for external power
Please pay attention to the correct polarity!
Digital display and variable output voltage:
6
5
Der Gigabit Ethernet PoE++ Splitter EX60327 teilt das Signal eines PoEServers (PSE) in --
Daten und Stromversorgung auf und gibt beide Signale getrennt aus. Damit können auch nicht
PoEfähige EthernetEndgeräte (IPKameras, WLANAccessPoints...) an einen PoESwitch ------
oder anderen PSE angeschlossen werden und dessen Stromversorgung nutzen. Er entspricht
dem PoE++ Standard IEEE 802.3bt. Die Spannung am Terminal Block zur Versorgung des
Endgerätes kann individuell zwischen 3VDC und 36VDC eingestellt werden. Die maximale
Ausgangsleistung beträgt 50W bei max. 10A. Durch das robuste Metallgehäuse und den
erweiterten Betriebstemperaturbereich von 40°C bis 75°C eignet sich der EX60327 für eine --
Vielzahl von Anwendungen auch in rauen Umgebungen. Zum Lieferumfang gehören ein
vormontiertes DINRackKit und eine Wandmontagehalterung.--
Kompatibilität:Gigabit Ethernet 10/100/1000BaseT-
PoE: IEEE 802.3af/at/bt (PoE++)
Ausgang:- 336VDC, max. 50W/10A
Betriebssysteme: Alle Betriebssysteme
Anschlüsse:- 2x RJ45Buchse, 1x Terminal Block
Lieferumfang:60327, DINRail Kit, Wandmontagehalterung, AnleitungEX--
1
BESCHREIBUNG & TECHNISCHE DATEN
AUFBAU
CONNECTORS & DISPLAY
HARDWAREINSTALLATION
Switzerland:
EXSYS Vertriebs GmbH
Dübendorfstrasse 17
8602 Wangen
www.exsys.ch
Germany:
EXSYS Vertriebs GmbH
Industriestrasse 8
61449 Steinbach
www.exsys.de
Italy:
EXSYS Italia Srl
Via Belvedere, 45/B
I22100 Como -
www.exsys.it
E6032
Anleitun
Vers. 1.0 / 20.09.24
Anzeige Ausgangs-
spannung/strom-
RJ45Downlink-
(Daten)
RJ45Uplink-
(PoE/Daten)
Stromausgang
via TBlock-
Please read the following installation instructions.
1.--Install the EX60326 on a mounting rail using the DINRail kit or on the wall using the wall
mounting brackets.
2.Connect your PoE PSE (Power Sourcing Equipment) to the Ethernet uplink port (PoE++
Data).
3.The digital display will now show the set output voltage. Use the supplied screwdriver to
set the correct output voltage for the end device you wish to power with the EX-60327.
4.Connect your Ethernet end device (e.g. IP camera, IP phone, ...) to the Ethernet downlink
port (Data) and the terminal block (pay attention to the polarity).
5.The digital display will now show the power consumption of the terminal device in addition
to the voltage.
The DINRail Kit is preassembled with --
two screws on the rear side
To install the wall mount, the DIN-
Rail kit must be replaced by the
mounting bracket
RJ45 Port
PinSignalPoE (Mode)PinSignalPoE (Mode)
1BI_DA+VCC+ (A)5BI_DCVCC+ (B) -
2BI_DAVCC+ (A)6BI_DBVCC (A)- - -
3BI_DB+VCC (A)7BI_DD+VCC (B) - -
4BI_DC+VCC+ (B)8BI_DDVCC (B) - -
RJ45 Port:
87654321
V
A
ADJ
The digital display shows the set output voltage and the
current power consumption of the connected load.
The output voltage can be continuously adjusted
between 3 VDC and 36 VDC using the supplied
screwdriver.
Voltage
TECHNICAL NOTE
Procedure for STP Cable Grounding
When using shielded cables to connect two Ethernet devices, a ground loop may occur if the
shielding on the cables generates an additional grounding connection path. This can cause
ground current to flow through to the Ethernet ports and damage the devices. If it is necessary
to use shielded cables, we recommend using a metallic RJ45 connector on one end and a non-
metallic connector on the other end. Alternatively, a patch panel can be used in between the
two devices to prevent ground loops from occurring.
For connections over short distances (e.g., between two devices installed in the same cabinet),
both ends of the shielded cable can be referenced to the same grounding point. Therefore, in
this case, it is acceptable to use a shielded cable with metallic RJ45 connectors on both