Dometic Magdry P030 Handleiding

Dometic Airco Magdry P030

Lees hieronder de 📖 handleiding in het Nederlandse voor Dometic Magdry P030 (20 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
MARINE
MAGNETIC-DRIVE PUMPS
Form No. 341460 12/20 | Š2020 Dometic Corporation
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
P030, P045, P048, P075, P100, P137, P150, P200
EN Magnetic-Drive Centrifugal Pump
Installation and Operation Manual
. . . . . . . .
2
2EN
Contents Magnetic-Drive Centrifugal Pump
1 Explanation of Symbols and Safety
Instructions 2
............................
1.1 Recognize Safety Information
.............
2
1.2 Understand Signal Words
................
2
1.3 Supplemental Directives
.................
3
1.4 General Safety Messages
................
3
2 Intended Use 4
...........................
3 General Information 5
.....................
4 Specifications
..........................
5
4.1 Maximum Surface Temperature
...........
5
4.2 Minimum Flow Rate
. . . . . . . . . . . . . . . . . . . . .
5
5 Installation
.............................
6
5.1 Selecting the Pump Location
.............
6
5.2 Rotating the Pump Head (Optional)
. . . . . . . .
6
5.3 Mounting the Pump
....................
8
5.4 Connecting the Piping
..................
8
5.5 Connecting a Drain Plug or Valve (Optional) . 9
5.6 Making the Electrical Connections
. . . . . . . . .
9
6 Operation
..............................
9
6.1 Priming the Pump
. . . . . . . . . . . . . . . . . . . . . .
9
6.2 Starting the Pump
. . . . . . . . . . . . . . . . . . . . . .
9
6.3 Verifying the Rotation of the Motor 10 . . . . . . . .
6.4 Shutting Down the Pump 10 . . . . . . . . . . . . . . .
7 Maintenance
..........................
10
7.1 Recommended Maintenance Schedule 10 . . . .
7.2 Flushing and Draining the Pump 10 . . . . . . . . . .
7.3 Disassembling the Pump. . . . . . . . . . . . . . . . 11
7.4 Inspecting the Pump Components 13
. . . . . . .
7.5 Installing Pump Wear Kit (Optional) 13
. . . . . . .
7.6 Installing a Pump Wet End Replacement Kit
(Optional) 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.7 Reassembling the Pump 14 . . . . . . . . . . . . . . . .
8 Troubleshooting
.......................
16
9 Disposal
..............................
16
10 Warranty Information 16
...................
Contents
Service Center & Dealer Locations
Visit: www.dometic.com
These instructions stay with this product.MUST
1 Explanation of Symbols and
Safety Instructions
This manual has safety information and instructions to
help you eliminate or reduce the risk of accidents and
injuries.
1.1 Recognize Safety Information
This is the safety alert symbol. It is used to alert
you to potential physical injury hazards. Obey all
safety messages that follow this symbol to avoid
possible injury or death.
1.2 Understand Signal Words
A signal word will identify safety messages and property
damage messages, and also will indicate the degree or
level of hazard seriousness.
DANGER!
Indicates a hazardous situation that, if avoided, not
will result in death or serious injury.
WARNING
Indicates a hazardous situation that, if avoided, not
could result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if avoided, not
could result in minor or moderate injury.
NOTICE: Used to address practices related to not
physical injury.
IIndicates additional information that is related not
to physical injury.
3
EN
Magnetic-Drive Centrifugal Pump Explanation of Symbols and Safety Instructions
1.3 Supplemental Directives
To reduce the risk of accidents and injuries, please
observe the following directives before proceeding to
install or operate this product:
• Read and follow all safety information and
instructions.
• Read and understand these instructions before
installing or operatingthis product.
• The installation must comply with all applicable local
or national codes, including the latest edition of the
following standards:
U.S.A.
– ANSI/NFPA70, National Electrical Code (NEC)
– American Boat and Yacht Council (ABYC)
Canada
– CSA C22.1, Parts l & ll, Canadian Electrical Code
1.4 General Safety Messages
WARNING: MAGNETIC HAZARD. Failure to
obey the following warnings could result in
death or serious injury:
• Individuals with cardiac pacemakers, implanted
debrillators, other electronic medical devices,
metallic prosthetic heart valves, internal wound clips
(from surgery), metallic prosthetic devices or sickle
cell anemia handle or be in the proximity of must not
the magnets inside this pump. Consult a health care
provider before working with this pump.
• Do place fingers between the mating surfaces of not
the motor and wet end of this pump. The magnetic
force is powerful enough to rapidly pull the motor
end and the wet end together.
WARNING: ELECTRICAL SHOCK, FIRE, AND/
OR EXPLOSION HAZARD. Failure to obey the
following warnings could result in death or
serious injury:
• Use only Dometic replacement parts and
components that are specically approved for use
with the product.
• Avoid improper installation, adjustment, alterations,
service, or maintenance of the product. Service and
maintenance be done by a qualied service must
person only.
• Do modify this product in any way. Modification not
can be extremely hazardous.
• Before attempting to make any electrical connections,
ensure the electrical power is off and the water valves
are completely closed.
• Secure and seal all wire connections to protect from
arcing.
• Do operate the pump in a highly-explosive not
environment unless the pump has a label to indicate
it is rated for ignition protection. Refer to labeling on
the pump to determine the environmental limitations
for operation near gasoline or other explosives.
• Do pump flammable or combustible liquids.not
• Disconnect the pump from the power supply before
cleaning and/or servicing. Maintenance be must
done by a qualied service person only.
WARNING: FLOOD/LEAK HAZARD. Failure to
obey the following warnings could result in
death or serious injury.
• Do perform service or maintenance when the not
pumping system is pressurized.
• Do mount the pump such that high piping loads not
exist on the pump connections, or in a rigid system
that does not allow the pipe to expand, causing the
pump to be strained.
• Do operate the pump beyond the pressure or not
temperature limits.
• Do allow severe temperature changes to occur in not
a short time period within the pumping system.
• Do continue to operate the pumping system not
when a known leak exists.
WARNING: IMPACT HAZARD.
This pump has components that rotate while
in operation. Follow local safety standards for
locking out the motor from the power supply
during maintenance or service. Failure to obey this
warning could result in death or serious injury.


Product specificaties

Merk: Dometic
Categorie: Airco
Model: Magdry P030

Heb je hulp nodig?

Als je hulp nodig hebt met Dometic Magdry P030 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Dometic

Handleiding Airco

Nieuwste handleidingen voor Airco