Bekijk gratis de handleiding van Doepfer A-151 (6 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 53 mensen en kreeg gemiddeld 3.5 sterren uit 27 reviews. Heb je een vraag over Doepfer A-151 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/6
doepfer System A - 100 Quad Sequential Switch A-151
1
1. Introduction
Module A-151 (Quad Sequential Switch) is like an
electronic four-position rotary switch.
It includes trigger and reset inputs, four in / out-
puts, and a common out / input.
Each time a pulse is received at the trigger input
socket, the common out / input is connected to the
next in / output. After the fourth in / output, the next
trigger makes it step back to the first again, and so on
(see Fig. 1).
Voltages in the range -8V...+8V at the O/I resp. I/O
sockets can be processed by the module.
Four LEDs indicate the active in / output (ie. the one
that is connected to the out / input at any particular
time).
A positive pulse at the reset input switches the out /
input immediately back to the first in / output (see Fig.
1).
Version 2 of the module (from about 2005) is equip-
ped with an additional switch that is used to set the
number of steps to 2, 3 or 4. On top of that the new
versions allows to switch audio or control signals
within the full A-100 voltage range (i.e. -12V...+12V).
Trig. In
A-151
SEQ. SWITCH
Res. In
O/I
I/O 1
I/O 2
I/O 3
I/O 4
A-151 Quad Sequential Switch System A - 100 doepfer
2
2. Overview Indicators:
1 LED: Indicator for in / output $
2 % LED: Indicator for in / output
3 LED: Indicator for in / output &
4 LED: Indicator for in / output /
5 Steps: Switch for the limitation of the num-
ber of addressed steps to 2, 3 or 4
(available only in version 2)
In / Outputs:
! Trig. In : Input for trigger pulse
" Res. In : Input for reset pulse
§ O/I : Common out / input
$ I/O 1 : In / output 1
% I/O 2 : In / output 2
& I/O 3 : In / output 3
/ I/O 4 : In / output 4
!
"
§
$
%
&
/
5
1
2
3
4
doepfer System A - 100 Quad Sequential Switch A-151
3
3. Indicators
1 LED • • • 2 LED 3 LED 4 LED
LEDs 1 to 4 are the status indicators, showing
which of sockets $ to / is connected to the common
out /input § at any moment.
5 Steps
This switch is used to limit the number of addressed
in/outputs to 2, 3 or 4. The switch is available on in
version 2 of the module (about since 2005).
4. In / Outputs
! Trig. In
Socket ! is the A-151’s trigger input. With each new
pulse (at the rising edge), the common out / input is
switched to the next in / output.
After stepping to the fourth in / output the next trigger
pulse sends the common out / input back to the first in
/ output again (see Fig. 1).
H Don’t forget that with a very fast repeating
trigger, the switching process on the A-151
can produce audio-frequency modulation
(see chapter 5, user examples).
" Res. In
If you want to over-ride the stepping sequence, and
send the common out /input back to the first in / output,
send a reset pulse to the reset input " (see Fig. 1).
The rising edge of this pulse immediately resets the
common out / input to the first in / output.
Using the reset input, you can create repeated se-
quences which switch between three inputs or outputs
($ Ö % Ö &
Ö $ Ö % Ö & Ö $...).
§ O/I
Socket $ is the common out /input. Each time the
A-100 is switched on, or a reset pulse is received, this
socket is connected to the first in / output socket $
(see Fig. 1).
$ I/O 1 • % & / I/O 2 I/O 3 I/O 4
Sockets $ to / are the in / outputs.