Delonghi PAC EX UV Carelight Handleiding
Bekijk gratis de handleiding van Delonghi PAC EX UV Carelight (8 pagina’s), behorend tot de categorie Airco. Deze gids werd als nuttig beoordeeld door 77 mensen. Heb je een vraag over Delonghi PAC EX UV Carelight of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 8/8

12
INTRODUCTION
Thank you for choosing a De’Longhi product. Please take a few
moments to read the instructions to avoid risks or damage to the
appliance.
DESCRIPTION
Description of the appliance (see page 3 - A)
A1air outlet ap
A2control panel
A3 handles
A4castors
A5BioSilver lter
A6air intake grille
A7air exhaust hose housing
A8air intake grille
A9power cable
A10drainage hose with cap
A11remote control signal receiver
A12remote control compartment
Description of the accessories (see page 3 - B)
B1wall ange with cap
B2air exhaust hose
B3hose adaptor
B4adapter for window bracket
B5window bracket with wing nut
B6adapter for wall mounting/window outlet
B7window outlet
B8remote control
B9window bracket cap
ELECTRICAL CONNECTION
Before plugging into the mains, check the following:
• the mains voltage is the same as that indicated on the plate
on the back of the appliance;
• the socket and electrical line are sized to support the load
required;
• the socket is the proper type for the plug, otherwise, re-
place the socket;
• the socket is connected to an ecient earthing system.
The manufacturer is not responsible in the event of non-
compliance with these injury prevention standards.
The power cable must only be replaced by specialised
technicians.
USE
The instructions below will enable you to prepare your air con-
ditioner for operation as eciently as possible. Before use, make
sure the air intake and outlet grilles are unobstructed.
Please note: This appliance is provided with an auto-evapora-
tion feature for condensate removal during cooling and dehu-
midifying modes.
AIR CONDITIONING WITHOUT INSTALLATION
CASEMENT WINDOW
If you have a casement window proceed as follows:
• Fit the air exhaust hose (B2) in the relevant housing located
on the rear side of the appliance (g. 1).
• Screw the window outlet(B7) and place outside the win-
dow to exhaust the hot air (g. 2).
DOUBLEHUNG WINDOW
If you have a double-hung window proceed as follows:
• Insert and lock the adapter for window bracket (B4) into
the slot of the window bracket (B5) (g.3)
• Place the window bracket in the window sill, and extend
the bracket fully within the window frame (g. 4).
• Fix the bracket by the wing nut (g. 5) (Should the window
bracket be too large for the window the plastic can be cut
with a saw by a qualied professional).
• Insert the air exhaust hose (B2) into the adapter for win-
dow bracket (B4) and rotate it as shown in g. 6.
• In order to facilitate the tting of the air exhaust hose (B2)
in the relevant housing located on the rear side of the ap-
pliance, position the hose adapter ‘s tabs (B3) in a vertical
axis as shown in g. 7 and proceed as shown in g.1.
SLIDING WINDOWS
• Thanks to the locking wing nut, it’s possible to use the win-
dow bracket also for sliding windows. Position the bracket
vetically with the hole in the lower part so to allow a easier
installation of the exhaust hose.
AIR CONDITIONING WITH INSTALLATION
• Fit the air exhaust hose (B2) in the relevant housing located
on the rear side of the appliance (g. 1).
• Drill a hole 150 mm in an outside wall or through a window
panel. Respect the distances, dimensions and heigh of the
hole given in gure 8.
Product specificaties
| Merk: | Delonghi |
| Categorie: | Airco |
| Model: | PAC EX UV Carelight |
Foutcodes Delonghi PAC EX UV Carelight
Foutcodes uit de officiële handleiding, met betekenis en oplossing.
| Code | Betekenis | Oplossing | Pagina |
|---|---|---|---|
| HL | Hoog niveau (interne opvangbak vol). | Leeg de interne veiligheidsopvangbak volgens de instructies in het hoofdstuk "Handelingen aan het einde van het seizoen". | 8 |
| Ht | Hoge temperatuur. Een oververhittingsbeveiliging schakelt het apparaat naar alleen ventileren als de kamertemperatuur lange tijd te hoog is. | Het apparaat wordt automatisch hersteld zodra de temperatuur dicht bij de grenswaarden voor werking ligt. | 8 |
| Lh | Lage luchtvochtigheid. Verschijnt alleen in de Real Feel-functie en geeft aan dat de luchtvochtigheid in de kamer extreem laag is. | Schakel het apparaat naar een andere modus dan de Real Feel-functie om de werking te hervatten. | 8 |
| Lt | Lage temperatuur (vorstbeveiliging). Het apparaat heeft een vorstbeveiliging om overmatige ijsvorming te voorkomen. | Het apparaat start automatisch weer op wanneer het ontdooiproces is voltooid. | 8 |
| PF | Sondestoring (sonde beschadigd). | Neem contact op met het gratis klantenservicenummer. | 8 |
Heb je hulp nodig?
Als je hulp nodig hebt met Delonghi PAC EX UV Carelight stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Delonghi
Delonghi Pinguino PAC EM82 Handleiding Delonghi PACC120E Handleiding Delonghi Pinguino PAC EL98 ECO Real Feel Handleiding Delonghi Pinguino PAC 50 Handleiding Delonghi Pinguino PAC L 35 Handleiding Delonghi Pinguino PAC AN120EW Handleiding Delonghi Pinguino PAC A100 ECO Handleiding Delonghi Pinguino PAC C120E Handleiding Delonghi Pinguino PACN80.1 Handleiding Delonghi Pinguino PAC 45 Handleiding
Alle Delonghi Airco handleidingen
Populair in Airco
Delonghi PAC WE128ECO Handleiding Delonghi Pinguino PAC N77 ECO Handleiding Delonghi PACEM93 Handleiding
Handleiding Airco
Nieuwste handleidingen voor Airco
Westinghouse WSD51HWC-E Handleiding Westinghouse WSD27HWC-E Handleiding Westinghouse WSD51HWC-I Handleiding Westinghouse WSD35HWC-E Handleiding Samsung SH18TA1 Handleiding Samsung SH09YABX Handleiding HTW MINI VRF V10B Handleiding Hisense AMW5-125U4RTAG Handleiding Westinghouse WSD79HWC Handleiding Samsung SH07YAB Handleiding