Datalogic DS8100A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Datalogic DS8100A (141 pagina's) in de categorie Barcode lezer  . Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/141
DS8100A
Reference Manual
Datalogic Automation Srl
Via Lavino, 265
40050 - Monte S. Pietro
Bologna - Italy
DS8100A Reference Manual
Ed.: 10/2012
© 2005 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest
extent under U.S. and international laws. Copying, or altering of this document is prohibited without
express written consent from Datalogic Automation S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U.
Genius, PackTrack, ACR, ASTRA, CD SQUARE and ID-NET are trademarks of Datalogic Automation
S.r.l. All other brand and product names mentioned herein are for identification purposes only and may
be trademarks or registered trademarks of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
incidental or consequential damages resulting from the use of this material.
02/10/12
iii
CONTENTS
REFERENCES ............................................................................................................ vi
Reference Documentation ........................................................................................... vi
Services and Support .................................................................................................. vi
Patents......................................................................................................................... vi
COMPLIANCE............................................................................................................ vii
Electrical Safety ...........................................................................................................vii
Laser Safety.................................................................................................................vii
Power Supply..............................................................................................................viii
CE Compliance...........................................................................................................viii
FCC Compliance ......................................................................................................... ix
GENERAL VIEW .......................................................................................................... x
GUIDE TO INSTALLATION ....................................................................................... xii
Point-to-Point Installation.............................................................................................xii
Master/Slave Lonworks Installation ............................................................................xiii
1 1 INTRODUCTION ..........................................................................................................
1.1 Product Description ...................................................................................................... 1
1.2 Applications .................................................................................................................. 1
1.3 Model Description.........................................................................................................3
1.4 Oscillating Mirror Models ..............................................................................................3
1.5 Indicators ...................................................................................................................... 4
1.6 Keypad and Display......................................................................................................5
1.6.1 Internal Net ...................................................................................................................5
1.6.2 Test Mode.....................................................................................................................5
1.6.3 PackTrack (Auto) ..........................................................................................................6
1.7 Auto PackTrack™ Calibration for Reading Station Using Scanner Menu .................... 7
1.7.1 Auto PackTrack Conditions and Limits .........................................................................7
1.7.2 Auto PackTrack Parameter Descriptions......................................................................8
1.7.3 Auto PackTrack Setup ..................................................................................................9
1.8 Accessories ................................................................................................................12
2 INSTALLATION ......................................................................................................... 14
2.1 Package Contents ......................................................................................................14
2.2 Mechanical Mounting..................................................................................................15
2.2.1 Mounting the Scanner.................................................................................................15
2.2.2 Mounting the Scanner with Accessories.....................................................................16
2.3 Positioning the Scanner..............................................................................................18
3 CBX ELECTRICAL CONNECTIONS......................................................................... 19
3.1 Power Supply..............................................................................................................21
3.2 Main Serial Interface...................................................................................................21
3.2.1 RS232 Interface..........................................................................................................22
3.2.2 RS485 Full-Duplex Interface.......................................................................................23
3.2.3 RS485 Half-Duplex Interface ......................................................................................24
3.3 Auxiliary RS232 Interface ...........................................................................................26
3.4 Inputs .......................................................................................................................... 27
3.4.1 Code Verifier...............................................................................................................31
3.5 Outputs .......................................................................................................................31


Product specificaties

Merk: Datalogic
Categorie: Barcode lezer  
Model: DS8100A
Kleur van het product: Grey, White
Gewicht: 5000 g
Materiaal behuizing: Aluminium
Stroomvoorziening: 30 VCD
LED-indicatoren: Stroom
Beeldscherm: LCD
Gewicht basisstation: 6400 g
Aantal toetsen: 3 toetsen
Type beeldsensor: Laser
Temperatuur bij opslag: -20 - 70 °C
Standaard interfaces: RS-232, RS-485
Afmetingen (B x D x H): 215.5 x 170.5 x 126.5 mm
Bedrijfstemperatuur (T-T): 0 - 50 °C
Lichtbron: 630 - 680
Lees-snelheid (max): 1000 lezingen/s