Daikin EWLT100Q Handleiding


Bekijk gratis de handleiding van Daikin EWLT100Q (74 pagina’s), behorend tot de categorie Hardwarekoeling. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.6 sterren uit 1.5 reviews. Heb je een vraag over Daikin EWLT100Q of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/74
Original instructions
Public
REV
01
Date
02/2025
Supersedes
D-EIMHP01702-23_00EN
Water Cooled Chiller & heat pump with Scroll Compressors
EWWT100-160Q Water-cooled scroll chiller
EWLT100-160Q Condenserless scroll chiller
EWHT100Q Water-cooled scroll Heat pump
Installation, Operation and Maintenance Manual
D-EIMHP01702-23_01EN
D-EIMHP01702-23_01EN- 2/74
Contents
1 INTRODUCTION ................................................................................................................................................. 13
Precautions against residual risks ....................................................................................................................... 13
General description ............................................................................................................................................. 14
Information about the refrigerant used ................................................................................................................ 14
Installation requirements ..................................................................................................................................... 14
1.1. Information about installation of systems with R32 ............................................................................................. 15
2 RECEIVING THE UNIT ....................................................................................................................................... 17
3 OPERATING LIMITS .......................................................................................................................................... 18
Storage ............................................................................................................................................................... 18
Operating limits ................................................................................................................................................... 18
4 MECHANICAL INSTALLATION ......................................................................................................................... 20
Safety .................................................................................................................................................................. 20
Handling and lifting .............................................................................................................................................. 20
Positioning and assembly ................................................................................................................................... 22
Noise and sound protection ................................................................................................................................ 22
Water circuit for the connection of the unit .......................................................................................................... 22
4.5.1 Water piping .......................................................................................................................................................... 22
4.5.2 Water piping installation procedure ....................................................................................................................... 23
4.5.3 Piping insulation .................................................................................................................................................... 28
Water treatment .................................................................................................................................................. 28
Operating stability and minimum water content in the system ............................................................................ 29
Anti-freeze protection for evaporator and recovery exchangers .......................................................................... 29
5 GUIDELINES FOR REMOTE CONDENSER APPLICATION (EWLT-Q VERSION) .......................................... 30
Selection of piping material ................................................................................................................................. 30
Installation information for condenserless units .................................................................................................. 30
Connecting the refrigerant circuit ........................................................................................................................ 30
5.3.1 To braze the pipe end ........................................................................................................................................... 32
Leak test and vacuum drying .............................................................................................................................. 32
Charging the unit ................................................................................................................................................. 32
5.5.1 Fine-tuning of refrigerant charge while unit is operating ....................................................................................... 33
5.5.2 Oil charge ............................................................................................................................................................. 33
6 ELECTRICAL INSTALLATION .......................................................................................................................... 34
To install the main switch handle and shaft ......................................................................................................... 34
General specifications ......................................................................................................................................... 35
6.2.1 About electrical compliance (only for EWWT100) ................................................................................................. 36
Electrical supply .................................................................................................................................................. 36
Electric connections ............................................................................................................................................ 36
Cable requirements ............................................................................................................................................. 37
Phase unbalance ................................................................................................................................................ 37
Connection of the power supply of the unit ......................................................................................................... 37
Electrical panel label description ......................................................................................................................... 38
7 ADDITIONAL GUIDELINES FOR MODULAR APPLICATIONS ........................................................................ 39
Water manifold module installation ..................................................................................................................... 39
7.1.1 Connection between manifold module and chiller unit .......................................................................................... 39
7.1.2 Partial Heat Recovery with manifold module ........................................................................................................ 40
7.1.3 Reference drawing in case of custom water piping ............................................................................................... 41
Connection of modular system ............................................................................................................................ 41
7.2.1 Mechanical connection ......................................................................................................................................... 41
7.2.2 Water manifold connection ................................................................................................................................... 42
Motor for Plate Heat Exchanger Shut-Off Valve .................................................................................................. 42
7.3.1 Motor mechanical installation ................................................................................................................................ 43
7.3.2 Valve actuator and Limit Switch electrical installation ........................................................................................... 44
7.3.3 Setting of Limit Switches trigger ............................................................................................................................ 47
Connection of stacked units ................................................................................................................................ 48
Connection of more unit-manifold systems together ........................................................................................... 48
Pump module installation .................................................................................................................................... 49
Handling of the Modules ..................................................................................................................................... 50
Electrical installation of modules ......................................................................................................................... 52
7.8.1 Power bar system mechanical installation ............................................................................................................ 53
7.8.2 Power bar system electrical connection ................................................................................................................ 54
Fuses replacement for power bar system ........................................................................................................... 57
7.9.1 M/S (MUSE) probes installation ............................................................................................................................ 58
7.9.2 Unit modules M/S (MUSE) connection.................................................................................................................. 60
Before starting ..................................................................................................................................................... 60
8 OPERATOR'S REPONSIBILITIES ..................................................................................................................... 62
9 MAINTENANCE .................................................................................................................................................. 63
Pressure / temperature table ............................................................................................................................... 64
Routine maintenance .......................................................................................................................................... 64
9.2.1 Electrical maintenance .......................................................................................................................................... 64
9.2.2 Service and limited warranty ................................................................................................................................. 64
10 BEFORE START-UP .......................................................................................................................................... 66
11 DISCHARGE OF THE REFRIGERANT FROM THE SAFETY VALVES ............................................................ 68


Product specificaties

Merk: Daikin
Categorie: Hardwarekoeling
Model: EWLT100Q

Heb je hulp nodig?

Als je hulp nodig hebt met Daikin EWLT100Q stel dan hieronder een vraag en andere gebruikers zullen je antwoorden