CyberData Systems 011462 Handleiding
CyberData Systems
Telefoon
011462
Bekijk gratis de handleiding van CyberData Systems 011462 (3 pagina’s), behorend tot de categorie Telefoon. Deze gids werd als nuttig beoordeeld door 16 mensen en kreeg gemiddeld 4.9 sterren uit 8.5 reviews. Heb je een vraag over CyberData Systems 011462 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/3

Quick Start Guide 931484A
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operation Guide,
which is available in the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011462/
Note You can also navigate to the Downloads tab by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
PoE Switch PoE Injector
Set PoE power type to Class 0 = 15.4W CAT6 cable recommended—
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100Mbps
1
3 4
2
Part Number: 011462
SIP Armored Steel Ringdown Phone
SIP Armored Steel Ringdown Phone
Quick Start Guide
The IP Endpoint Company

Quick Start Guide 931484A
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity above the
ethernet port on the board. See the following figure:
3.2. The amber 100 Mb Link LED blinks off once during the boot up process
when the device begins DHCP addressing and autoprovisioning attempts,
and then comes on again and remains constant (solid amber). The green
Link/Activity LED may be blinking depending on the network activity.
Note The default DHCP addressing timeout is 60 seconds. The device will attempt
DHCP addressing 12 times with a 3 second delay between tries and eventually
fall back to the programmed static IP address (by default 10.10.10.10) if DHCP
addressing fails. The DHCP Timeout is configurable in the device's Network
settings.
3.3. When the device has completed the initialization process, press and hold
the RESET switch (SW1 button) for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
100 Mb Link LED
Link/Activity J1

Quick Start Guide 931484A
4.0 Connecting to a Network in a Test Environment
Note The following connections are usually needed for this procedure:
• Computer
• PoE switch or injector
• CyberData device
4.1. In a test environment, use a computer that is connected to the same switch
as a single CyberData device. Note the subnet of the test computer.
4.2. Use the CyberData Discovery Utility program to locate the device on the
network. You can download the Discovery Utility program from the following
link:
http://www.cyberdata.net/assets/common/discovery.zip
4.3. Wait for initialization to complete before using the Discovery Utility program
to scan for a device. The device will show the current IP address, MAC
address, and serial number.
4.4. Select the device.
4.5. Click Launch Browser. If the IP address is in a reachable subnet from the
computer that you are using to access the device, the Discovery Utility
program should be able to launch a browser window pointing to the device’s
IP address.
4.6. Log on to the web interface by using the default username (admin) and
password (admin) to configure the device.
4.7. Perform an audio test by pressing the Test Audio button that is located at
the bottom of the Device Configuration page. If the audio test message is
clearly audible, then your CyberData device is functioning properly.
4.8. The device is now ready to be set for your desired network configuration.
You may search the Compatible IP-PBX Servers index for available
sample VoIP phone system configurations and set up guides at the following
website address:
http://www.cyberdata.net/connecting-to-ip-pbx-servers/
Product specificaties
Merk: | CyberData Systems |
Categorie: | Telefoon |
Model: | 011462 |
Kleur van het product: | Black, Stainless steel |
Gewicht: | 1820 g |
Breedte: | 130 mm |
Diepte: | 127 mm |
Hoogte: | 229 mm |
Gewicht verpakking: | 2700 g |
Internationale veiligheidscode (IP): | IP66 |
Bluetooth: | Nee |
Stemcodecs: | G.711alaw, G.722 |
Ethernet LAN: | Ja |
Certificering: | CE; EMC Directive – Class A EN 55032 & EN 55024, LV Safety Directive – EN 60950-1, RoHS Compliant, FCC; Part 15 Class A, Industry Canada; ICES-3 Class A |
Duurzaamheidscertificaten: | CE |
Ruisonderdrukking: | Ja |
Temperatuur bij opslag: | -40 - 70 °C |
Camera voorzijde: | Nee |
Naleving van duurzaamheid: | Ja |
Ophangsysteem voor aan de muur: | Ja |
Power over Ethernet (PoE): | Ja |
Handset type: | Handset met snoer |
Capaciteit telefoonboek: | - entries |
VoIP protocollen: | SIP RFC 3261 |
Lijn-kwantiteit: | - regels |
Wifi: | Nee |
Bedrijfstemperatuur (T-T): | -40 - 60 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Type product: | IP Phone |
Huls materiaal: | Staal |
Compatibel met gehoorapparaten: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberData Systems 011462 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Telefoon CyberData Systems
5 Maart 2024
11 November 2023
11 November 2023
11 November 2023
Handleiding Telefoon
- Trevi
- Blaupunkt
- Edenwood
- Audioline
- Mitel
- Profoon
- Blackberry
- FlyingVoice
- Cisco
- Ascom
- Vogtec
- Audio-Technica
- Vimar
- CAT
- Valcom
Nieuwste handleidingen voor Telefoon
15 Juni 2025
15 Juni 2025
15 Juni 2025
12 Mei 2025
12 Mei 2025
12 Mei 2025
12 Mei 2025
12 Mei 2025
12 Mei 2025
12 Mei 2025