Bekijk gratis de handleiding van Chapin 6-9216 (16 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 7 mensen en kreeg gemiddeld 5.0 sterren uit 4 reviews. Heb je een vraag over Chapin 6-9216 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/16

Chapin International, Inc
P.O. Box 549 700 Ellicott St.
Batavia, NY 14021-0549 U.S.A.
1-800-950-4458 www.chapinmfg.com
5.0 GPM 12V DIAPHRAGM PUMP
Model 6-9216
017642R1023
Carefully Read These Instructions Before Use
WARNING
INSTRUCTION MANUAL
DO NOT RETURN TO STORE
Call: 1-800-950-4458
www.chapinmfg.com

1E
Instrucon Manual - English
1. Alway choose the dryest location away from any source of heat. If an enclosure is
needed, special instructions for cooling the motor may be necessary. Consult Chapin
Customer service 1-800-950-4458.
2. The pump may be mounted horizontally with the outlet port on the right when viewed
from the pump end or with the pump above the mount, or vertically with the pump above
or below the motor.
3. Keep the p ile in operation.
Follow a reco F).
Plumbing:
1. Use suction hose on inlet of pump. Flexible tubing is required with proper pressure
rating. (Minimum of 3/8” I.D.)
2. To prime, first relieve all pressure from the outlet port.
3. Install an inline sediment filter (50 mesh) to keep foreign debris out of the system. If
a check valve is needed, use valve rated with a cracking pressure of no more than 2 PSI
(0.14 bar).
4. Always install tubing to maintain a unincumbered path to avoid crimping. Use 90’ elbow
fittings if necessary.
5. Always mount pump before other components to avoid introducing particles to the
water. This will prevent possible pump damage or failure from foreign debris.
Electrical:
1. This pump is designed for intermittent operation. There should be downtime in between
use. Do not run indefinitely. Consult Chapin Customer service 1-800-950-4458.
2. Always use proper power supply to avoid pump damage or failure.
3. Pump and motor specs are based on an alternator charged battery (13.2 VDC).
4. Use a sufficient battery supply power. Some smaller ATV and lawn tractor batteries
may affect pump performance due to low voltage and amp ratings. Consult battery
manufacturer’s specifications for proper compatibility.
Mounting:
Mount your pump in an optimal location
Installation Recommendations

2E
Instrucon Manual - English
Installation and Operation Precautions
1. DO NOT subject the pump to pressures above 125 PSI (8.5 bars)
2. As long as there is inlet water pressure, the pump will not stop forward flow of water
even if the motor is turned off. Be sure the system has positive means of shutting off
water supply.
3. operate pump in an explosive environment. Arcing from the motor brushes, DO NOT
switch or excessive heat from an improperly cycled motor may cause an explosion.
4. DO NOT locate the pump motor near combustible material. The surface temperature of
the motor can exceed 250’ F (120° C).
5. pump gasoline, diesel fuel, petroleum products or other flammable liquids. The DO NOT
pump head materials and elestomers are designed FOR USE WITH WATER ONLY.
6. Not all fluids/chemicals are compatible with this pump. Pump elastomers may fail and
cause leaks if used incorrectly, left to sit in incompatable fluids.
7. To avoid electrical shock, disconnect power before working on this pump. Always
use caution In the case of pump failure, the housing and/or pump fluid may carry high
voltage to components and connections that are normally safe to touch. There is always
a possibility of electrical shock when working with and handling electrical components. If
unsure, consult a licensed electrician. Always use a qualified electrician for hardwiring and
completing electrical connections. Follow local and state electrical codes where applicable.
Installation & Operation
1. Water supply should be turned off or disconnected from source.
2. Trim flexible tubing to desired length for secure connection
3. Insert tubing into the 90˚ or straight quick connect fittings provided. Use the 90˚ fitting
if tubing crimps on entrance to, or exit from the pump. Clamp hose to fitting ( clamps
not included) and slide fitting onto quick attach brackets on the pump. Secure by sliding
locking tabs in place.
4. Your Chapin pump has a standard electrical connection with in-line fuse protection for
easy hook up with any 12v battery supply such as a graden tractor, ATV or UTV battery.
5. Your Chapin pump is ready for use.
6. The pump will begin building pressure. Operating pressure will vary with flow rate, flow
valve, feed-water pressure and line voltage. Check for fitting leaks. Run for approximately
15 minutes. Note: further adjustments should not be necessary although it may take
several days of operation before all the air has been purged and the system is stabilized.
(1) 90˚ Quick
Attach Fitting
(2) Straight
Quick
Attach Fittings
Product specificaties
Merk: | Chapin |
Categorie: | Niet gecategoriseerd |
Model: | 6-9216 |
Heb je hulp nodig?
Als je hulp nodig hebt met Chapin 6-9216 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Chapin
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
Handleiding Niet gecategoriseerd
- EGO
- Powersoft
- Alcatel
- ModeCom
- Shindaiwa
- Stelzner
- Satel
- MyAVR
- Sureguard
- Cardiostrong
- Rug Doctor
- Doepke
- Krüger&Matz
- Micro Matic
- Cane Creek
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025